Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): Thermal conductivity of IODP Hole 333-C0012C [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.784997

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Other version:
IODP Hole 333-C0012C, snapshot taken on 2012-05-08, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/333/C0012C/
Coverage:
Latitude: 32.748245 * Longitude: 136.917362
Minimum DEPTH, sediment/rock: 0.300 m * Maximum DEPTH, sediment/rock: 125.040 m
Event(s):
333-C0012C * Latitude: 32.748245 * Longitude: 136.917362 * Elevation: -3510.5 m * Recovery: 128.62 m * Campaign: Exp333 (NanTroSEIZE Stage 2: Subduction Inputs 2 and Heat Flow) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor). VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 333 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 333 Scientists[m CSF-B] Top Core depth (below sea floor)
Conductivity, thermalkW/m/KExpedition 333 ScientistsAverage
CommentCommentExpedition 333 ScientistsThermal conductivity measurement horizon comment
NumberNoExpedition 333 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 333 ScientistsRun 1
CommentCommentExpedition 333 ScientistsRun 1 comment
Time StampTime StampExpedition 333 ScientistsRegistration
Size:
1339 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

k [W/m/K]
(Average)

Comment
(Thermal conductivity measurem...)

No
(Number of runs)

k [W/m/K]
(Run 1)

Comment
(Run 1 comment)

Time Stamp
(Registration)
333-C0012C-1H-1,30.00.3000.2820.872TC was replaced to the highest value.10.8721-3001..01 Power 4W/m V11036;2010-12-28T23:29:05
333-C0012C-1H-1,100.01.0000.9410.965TC was replaced to the highest value.10.9651-10001..01 Power 4W/m V11005;2010-12-28T23:29:28
333-C0012C-1H-2,37.01.7751.6710.900TC was replaced to the highest value.10.9002010-12-28T23:30:48
333-C0012C-1H-2,85.02.2552.1230.961TC was replaced to the highest value.10.9612010-12-30T00:02:07
333-C0012C-1H-3,30.03.1002.9180.992TC was replaced to the highest value.10.9922010-12-28T23:32:21
333-C0012C-1H-3,115.03.9503.7190.971TC was replaced to the highest value.10.9713-11501..01 Power 4W/m V11005;2010-12-28T23:33:16
333-C0012C-1H-4,20.04.4154.1560.964TC was replaced to the highest value.10.9642010-12-28T23:33:47
333-C0012C-2H-1,30.04.8004.7830.931TC was replaced to the highest value.10.9312010-12-28T23:34:16
333-C0012C-2H-1,100.05.5005.4440.952TC was replaced to the highest value.10.9523-11501..01 Power 4W/m V11005;2010-12-28T23:34:37
333-C0012C-2H-2,30.06.2156.1200.962TC was replaced to the highest value.10.9622010-12-28T23:36:38
333-C0012C-2H-2,100.06.9156.7810.940TC was replaced to the highest value.10.9403-11501..01 Power 4W/m V11005;2010-12-28T23:35:26
333-C0012C-2H-3,30.07.6207.4461.012TC was replaced to the highest value.11.0122010-12-28T23:35:59
333-C0012C-2H-3,101.08.3308.1170.987TC was replaced to the highest value.10.9873-11501..01 Power 4W/m V11005;2010-12-28T23:37:03
333-C0012C-2H-4,30.09.0258.7730.970TC was replaced to the highest value.10.9702010-12-28T23:37:27
333-C0012C-2H-4,100.09.7259.4341.028TC was replaced to the highest value.11.0283-11501..01 Power 4W/m V11005;2010-12-28T23:37:44
333-C0012C-2H-5,30.010.44010.1090.967TC was replaced to the highest value.10.9672010-12-28T23:38:06
333-C0012C-2H-5,100.011.14010.7700.949TC was replaced to the highest value.10.9493-11501..01 Power 4W/m V11005;2010-12-28T23:38:27
333-C0012C-2H-6,30.011.86511.4550.925TC was replaced to the highest value.10.9252010-12-28T23:38:47
333-C0012C-2H-6,105.012.61512.1630.883TC was replaced to the highest value.10.8833-11501..01 Power 4W/m V11005;2010-12-28T23:39:07
333-C0012C-2H-7,30.013.27012.7820.907TC was replaced to the highest value.10.9072010-12-28T23:39:27
333-C0012C-2H-7,100.013.97013.4430.887TC was replaced to the highest value.10.8873-11501..01 Power 4W/m V11005;2010-12-28T23:39:50
333-C0012C-3H-1,30.014.30014.2820.891TC was replaced to the highest value.10.8912010-12-28T23:40:11
333-C0012C-3H-1,100.015.00014.9410.886TC was replaced to the highest value.10.8863-11501..01 Power 4W/m V11005;2010-12-28T23:40:29
333-C0012C-3H-2,30.015.70515.6040.847TC was replaced to the highest value.10.8472010-12-28T23:40:55
333-C0012C-3H-2,100.016.40516.2620.885TC was replaced to the highest value.10.8853-11501..01 Power 4W/m V11005;2010-12-28T23:41:14
333-C0012C-3H-3,30.017.11016.9250.846TC was replaced to the highest value.10.8462010-12-28T23:41:40
333-C0012C-3H-3,105.017.86017.6310.937TC was replaced to the highest value.10.9373-11501..01 Power 4W/m V11005;2010-12-28T23:42:08
333-C0012C-3H-4,30.018.53518.2660.891TC was replaced to the highest value.10.8912010-12-28T23:42:30
333-C0012C-3H-4,100.019.23518.9240.932TC was replaced to the highest value.10.9323-11501..01 Power 4W/m V11005;2010-12-28T23:42:48
333-C0012C-3H-5,30.019.96019.6060.829TC was replaced to the highest value.10.8292010-12-28T23:43:10
333-C0012C-3H-5,100.020.66020.2640.869TC was replaced to the highest value.10.8693-11501..01 Power 4W/m V11005;2010-12-28T23:43:29
333-C0012C-3H-6,30.021.37520.9370.965TC was replaced to the highest value.10.9652010-12-28T23:43:49
333-C0012C-3H-6,90.021.97521.5010.896TC was replaced to the highest value.10.8963-11501..01 Power 4W/m V11005;2010-12-28T23:44:08
333-C0012C-3H-7,30.022.78022.2580.939TC was replaced to the highest value.10.9392010-12-28T23:44:29
333-C0012C-3H-7,100.023.48022.9170.921TC was replaced to the highest value.10.9213-11501..01 Power 4W/m V11005;2010-12-28T23:44:57
333-C0012C-4H-1,30.023.80023.7810.905TC was replaced to the highest value.10.9052010-12-28T23:45:18
333-C0012C-4H-1,100.024.50024.4360.916TC was replaced to the highest value.10.9163-11501..01 Power 4W/m V11005;2010-12-28T23:45:35
333-C0012C-4H-2,30.025.21525.1050.795TC was replaced to the highest value.10.7952010-12-28T23:45:59
333-C0012C-4H-2,100.025.91525.7600.94610.9463-11501..01 Power 4W/m V11005;2010-12-28T23:46:21
333-C0012C-4H-3,30.026.63026.4300.910TC was replaced to the highest value.10.9102010-12-28T23:46:41
333-C0012C-4H-3,100.027.33027.0850.922TC was replaced to the highest value.10.9223-11501..01 Power 4W/m V11005;2010-12-28T23:46:59
333-C0012C-4H-5,30.028.27527.9690.883TC was replaced to the highest value.10.8832010-12-28T23:47:22
333-C0012C-4H-5,75.028.72528.3900.912TC was replaced to the highest value.10.9123-11501..01 Power 4W/m V11005;2010-12-28T23:47:48
333-C0012C-4H-6,30.029.48529.1020.900TC was replaced to the highest value.10.9002010-12-28T23:48:12
333-C0012C-4H-6,100.030.18529.7570.925TC was replaced to the highest value.10.9253-11501..01 Power 4W/m V11005;2010-12-28T23:48:31
333-C0012C-4H-7,30.030.90530.4310.897TC was replaced to the highest value.10.8972010-12-28T23:48:51
333-C0012C-4H-7,100.031.60531.0860.906TC was replaced to the highest value.10.9063-11501..01 Power 4W/m V11005;2010-12-28T23:49:11
333-C0012C-4H-8,30.032.32531.7600.905TC was replaced to the highest value.10.9052010-12-28T23:49:31
333-C0012C-4H-8,100.033.02532.4150.95510.9553-11501..01 Power 4W/m V11005;2010-12-28T23:49:50
333-C0012C-5H-1,30.033.30033.2910.879TC was replaced to the highest value.10.8792010-12-28T23:50:11
333-C0012C-5H-1,100.034.00033.9690.882TC was replaced to the highest value.10.8823-11501..01 Power 4W/m V11005;2010-12-28T23:50:30
333-C0012C-5H-2,30.034.69534.6430.859TC was replaced to the highest value.10.8592010-12-28T23:50:52
333-C0012C-5H-2,90.035.29535.2250.95510.9553-11501..01 Power 4W/m V11005;2010-12-28T23:51:20
333-C0012C-5H-4,30.036.34536.2430.913TC was replaced to the highest value.10.9132010-12-28T23:51:41
333-C0012C-5H-4,100.037.04536.9210.959TC was replaced to the highest value.10.9593-11501..01 Power 4W/m V11005;2010-12-28T23:52:01
333-C0012C-5H-5,30.037.80537.6580.934TC was replaced to the highest value.10.9342010-12-28T23:52:25
333-C0012C-5H-5,100.038.50538.3360.921TC was replaced to the highest value.10.9213-11501..01 Power 4W/m V11005;2010-12-28T23:52:45
333-C0012C-5H-6,33.039.24539.0540.927TC was replaced to the highest value.10.9272010-12-28T23:54:40
333-C0012C-5H-6,100.039.91539.7030.90410.9043-11501..01 Power 4W/m V11005;2010-12-28T23:55:44
333-C0012C-5H-7,30.040.62540.3920.923TC was replaced to the highest value.10.9232010-12-28T23:56:32
333-C0012C-5H-7,100.041.32541.0700.932TC was replaced to the highest value.10.9323-11501..01 Power 4W/m V11005;2010-12-28T23:56:50
333-C0012C-5H-8,25.041.98541.7100.860TC was replaced to the highest value.10.8602010-12-28T23:57:13
333-C0012C-5H-8,65.042.38542.0980.862TC was replaced to the highest value.10.8623-11501..01 Power 4W/m V11005;2010-12-28T23:57:33
333-C0012C-5H-CC,17.042.65542.3590.919TC was replaced to the highest value.10.9192010-12-28T23:57:53
333-C0012C-6H-1,45.042.95042.9180.908TC was replaced to the highest value.10.9081-4501..01 Power 3W/m V11036;2010-12-28T23:58:16
333-C0012C-6H-1,100.043.50043.4300.920TC was replaced to the highest value.10.9201-10001..01 Power 3W/m V11005;2010-12-28T23:58:33
333-C0012C-6H-2,30.044.21544.0940.918TC was replaced to the highest value.10.9182010-12-28T23:59:05
333-C0012C-6H-2,100.044.91544.7450.92010.9202010-12-28T23:59:23
333-C0012C-6H-3,30.045.63545.4140.905TC was replaced to the highest value.10.9052010-12-28T23:59:47
333-C0012C-6H-3,100.046.33546.0650.927TC was replaced to the highest value.10.9272010-12-29T00:00:09
333-C0012C-6H-5,30.047.28546.9480.958TC was replaced to the highest value.10.9582010-12-29T00:00:31
333-C0012C-6H-5,100.047.98547.5990.960TC was replaced to the highest value.10.9602010-12-29T00:00:49
333-C0012C-6H-6,30.048.70548.2680.945TC was replaced to the highest value.10.9452010-12-29T00:01:09
333-C0012C-6H-6,100.049.40548.9180.964TC was replaced to the highest value.10.9642010-12-29T00:01:27
333-C0012C-6H-7,30.050.13049.5920.928TC was replaced to the highest value.10.9282010-12-29T00:01:50
333-C0012C-6H-7,100.050.83050.2430.957TC was replaced to the highest value.10.9572010-12-29T00:02:11
333-C0012C-6H-8,24.051.48050.8470.920TC was replaced to the highest value.10.9202010-12-29T00:02:34
333-C0012C-6H-8,101.052.25051.5630.939TC was replaced to the highest value.10.9392010-12-29T00:02:56
333-C0012C-6H-CC,18.052.54551.8370.902TC was replaced to the highest value.10.9022010-12-29T00:03:21
333-C0012C-7H-4,23.055.07554.8590.934TC was replaced to the highest value.10.9342010-12-29T00:03:44
333-C0012C-7H-6,51.057.69057.2900.835TC was replaced to the highest value.10.8352010-12-29T00:04:11
333-C0012C-7H-7,86.059.40058.8800.940TC was replaced to the highest value.10.9402010-12-29T00:04:33
333-C0012C-7H-8,67.060.29559.7120.879TC was replaced to the highest value.10.8792010-12-29T00:05:12
333-C0012C-7H-8,118.060.80560.1870.90810.9082010-12-29T00:05:33
333-C0012C-7H-CC,31.061.34560.6880.921TC was replaced to the highest value.10.9212010-12-29T00:05:56
333-C0012C-8H-1,85.060.85060.7900.909TC was replaced to the highest value.10.9092010-12-29T00:06:18
333-C0012C-8H-2,30.061.71061.5900.937TC was replaced to the highest value.10.9372010-12-29T00:06:38
333-C0012C-8H-2,101.062.42062.2500.938TC was replaced to the highest value.10.9382010-12-29T00:07:04
333-C0012C-8H-3,30.063.13562.9140.68810.6882010-12-29T00:07:24
333-C0012C-8H-3,93.063.76563.5000.94710.9472010-12-29T00:07:51
333-C0012C-8H-5,51.064.98564.6341.00111.0012010-12-29T00:08:12
333-C0012C-8H-5,101.065.48565.0990.88910.8892010-12-29T00:08:33
333-C0012C-8H-6,60.066.48066.0230.99710.9972010-12-29T00:08:58
333-C0012C-8H-6,108.066.96066.4700.942TC was replaced to the highest value.10.9422010-12-29T00:09:21
333-C0012C-8H-7,30.067.59067.0550.964TC was replaced to the highest value.10.9642010-12-29T00:09:43
333-C0012C-8H-7,100.068.29067.7060.97810.9782010-12-29T00:10:02
333-C0012C-8H-8,24.068.93568.3050.85610.8562010-12-29T00:10:25
333-C0012C-8H-8,81.069.50568.8350.902TC was replaced to the highest value.10.9022010-12-29T00:10:47
333-C0012C-9H-1,50.070.00069.9950.992TC was replaced to the highest value.10.9921-5001..01 Power 3W/m V11005;2010-12-29T00:11:09
333-C0012C-9H-1,125.070.75070.7380.992TC was replaced to the highest value.10.9922010-12-29T00:11:31
333-C0012C-9H-2,30.071.24571.2290.945TC was replaced to the highest value.10.9452010-12-29T00:11:55
333-C0012C-9H-2,100.071.94571.9220.98710.9872010-12-29T00:12:15
333-C0012C-9H-3,30.072.67072.6401.008TC was replaced to the highest value.11.0083-3001..01 Power 3W/m V11005;2010-12-29T00:12:37
333-C0012C-9H-3,100.073.37073.3340.967TC was replaced to the highest value.10.9672010-12-29T00:15:18
333-C0012C-9H-5,30.074.32574.2800.942TC was replaced to the highest value.10.9425-3001..01 Power 3W/m V11005;2010-12-29T00:15:45
333-C0012C-9H-5,100.075.02574.9730.943TC was replaced to the highest value.10.9432010-12-29T00:16:05
333-C0012C-9H-6,30.075.75575.6960.967TC was replaced to the highest value.10.9672010-12-30T00:05:32
333-C0012C-9H-6,100.076.45576.3901.007FTC was replaced to the highest value.11.0072010-12-30T00:05:56
333-C0012C-9H-7,30.077.19577.1230.824TC was replaced to the highest value.10.8242010-12-30T00:06:24
333-C0012C-9H-7,100.077.89577.8161.056TC was replaced to the highest value.11.0567-10001..01 Power 3W/m V11005;2010-12-30T00:06:45
333-C0012C-9H-8,30.078.60578.5201.155TC was replaced to the highest value.11.1552010-12-30T00:04:45
333-C0012C-10H-1,30.079.30079.2560.941TC was replaced to the highest value.10.9412010-12-30T00:07:11
333-C0012C-10H-1,90.079.90079.7671.120TC was replaced to the highest value.11.1202010-12-30T00:07:32
333-C0012C-10H-2,35.080.77080.5081.048TC was replaced to the highest value.11.0482010-12-30T00:07:59
333-C0012C-10H-2,100.081.42081.0630.974TC was replaced to the highest value.10.9742010-12-30T00:08:20
333-C0012C-10H-3,14.081.97081.5311.102TC was replaced to the highest value.11.1022010-12-30T00:08:43
333-C0012C-10H-4,15.082.23081.7531.15211.1522010-12-30T00:09:07
333-C0012C-10H-5,28.082.59082.0601.095TC was replaced to the highest value.11.0952010-12-30T00:09:32
333-C0012C-10H-5,85.083.16082.5461.025TC was replaced to the highest value.11.0252010-12-30T00:10:02
333-C0012C-10H-6,30.083.57582.8991.12111.1212010-12-30T00:10:27
333-C0012C-10H-6,100.084.27583.4961.12111.1212010-12-30T00:10:46
333-C0012C-10H-7,15.084.84083.9770.99110.9912010-12-30T00:11:11
333-C0012C-10H-8,30.085.21084.2931.171TC was replaced to the highest value.11.1718-3001..01 Power 3W/m V11005;2010-12-30T00:11:33
333-C0012C-10H-8,100.085.91084.8891.18211.1822010-12-30T00:11:53
333-C0012C-10H-9,30.086.42585.3281.075TC was replaced to the highest value.11.0752010-12-30T00:12:20
333-C0012C-10H-9,80.086.92585.7541.07211.0722010-12-30T00:12:44
333-C0012C-10H-CC,16.087.50086.2441.01411.014CC-1601..01 Power 3W/m V11005;2010-12-30T00:13:05
333-C0012C-11H-1,37.086.87086.8501.006TC was replaced to the highest value.11.0062010-12-30T00:13:29
333-C0012C-11H-1,110.087.60087.5391.065TC was replaced to the highest value.11.0652010-12-30T00:13:50
333-C0012C-11H-2,25.088.17088.0771.09011.0902010-12-30T00:14:16
333-C0012C-11H-2,100.088.92088.7861.07311.0732010-12-30T00:14:39
333-C0012C-11H-3,30.089.62589.4521.08611.0863-3001..01 Power 3W/m V11005;2010-12-30T00:15:03
333-C0012C-11H-4,30.090.26090.0521.087TC was replaced to the highest value.11.0872010-12-30T00:15:25
333-C0012C-11H-4,75.090.71090.4771.062TC was replaced to the highest value.11.0622010-12-30T00:15:47
333-C0012C-11H-5,22.091.39591.1240.880TC was replaced to the highest value.10.8802010-12-30T00:16:14
333-C0012C-11H-5,50.091.67591.3881.021TC was replaced to the highest value.11.0212010-12-30T00:16:37
333-C0012C-11H-7,20.092.22091.9030.991TC was replaced to the highest value.10.9912010-12-30T00:16:59
333-C0012C-11H-7,40.092.42092.0921.09911.0992010-12-30T00:17:23
333-C0012C-11H-8,30.093.03092.6681.097TC was replaced to the highest value.11.0972010-12-30T00:18:00
333-C0012C-11H-8,86.093.59093.1970.996TC was replaced to the highest value.10.9962010-12-30T00:18:23
333-C0012C-11H-CC,22.094.25593.8251.161TC was replaced to the highest value.11.1612010-12-30T00:18:45
333-C0012C-12H-1,30.094.30094.2721.07611.0762010-12-30T00:19:08
333-C0012C-12H-1,100.095.00094.9061.088TC was replaced to the highest value.11.0882010-12-30T00:19:27
333-C0012C-12H-2,30.095.72095.5581.11611.1162010-12-30T00:19:50
333-C0012C-12H-2,100.096.42096.1921.13311.1332010-12-30T00:20:11
333-C0012C-12H-3,30.097.12596.8311.10411.1042010-12-30T00:20:32
333-C0012C-12H-3,100.097.82597.4651.10211.1022010-12-30T00:20:51
333-C0012C-12H-4,30.098.53598.1091.07911.0792010-12-30T00:21:11
333-C0012C-12H-4,100.099.23598.7431.14211.1422010-12-30T00:21:34
333-C0012C-12H-5,30.099.94099.3821.103TC was replaced to the highest value.11.1032010-12-30T23:11:14
333-C0012C-12H-5,101.0100.650100.0251.11211.1122010-12-30T00:21:57
333-C0012C-12H-6,30.0101.345100.6551.172TC was replaced to the highest value.11.1722010-12-30T23:11:40
333-C0012C-12H-6,100.0102.045101.2891.14611.1462010-12-30T00:22:26
333-C0012C-12H-CC,37.0102.705101.8871.162TC was replaced to the highest value.11.1622010-12-30T23:12:06
333-C0012C-13H-1,30.0102.300102.2351.103TC was replaced to the highest value.11.1032010-12-30T23:12:32
333-C0012C-13H-1,100.0103.000102.7831.170TC was replaced to the highest value.11.1702010-12-30T00:24:38
333-C0012C-13H-2,30.0103.710103.3391.168TC was replaced to the highest value.11.1682010-12-30T23:12:59
333-C0012C-13H-2,101.0104.420103.8961.147TC was replaced to the highest value.11.1472010-12-30T00:25:01
333-C0012C-13H-3,30.0105.120104.4441.137TC was replaced to the highest value.11.1372010-12-30T23:13:23
333-C0012C-13H-3,100.0105.820104.9921.097TC was replaced to the highest value.11.0972010-12-30T00:25:21
333-C0012C-13H-5,29.0106.545105.5601.154TC was replaced to the highest value.11.1542010-12-30T23:13:53
333-C0012C-13H-5,71.0106.965105.8891.150TC was replaced to the highest value.11.1502010-12-30T00:25:46
333-C0012C-13H-6,30.0107.965106.6721.173TC was replaced to the highest value.11.1732010-12-30T23:14:22
333-C0012C-13H-6,101.0108.675107.2291.024TC was replaced to the highest value.11.0242010-12-30T00:29:29
333-C0012C-13H-CC,27.0109.345107.7531.133TC was replaced to the highest value.11.1332010-12-30T23:14:48
333-C0012C-14H-3,26.0108.885108.8041.140TC was replaced to the highest value.11.1402010-12-30T23:15:16
333-C0012C-14H-3,65.0109.275109.1581.15711.1572010-12-30T00:35:12
333-C0012C-14H-4,30.0109.730109.5711.124TC was replaced to the highest value.11.1242010-12-30T23:15:40
333-C0012C-14H-4,101.0110.440110.2161.10911.1092010-12-30T00:35:35
333-C0012C-14H-5,30.0111.135110.8471.125TC was replaced to the highest value.11.1252010-12-30T23:16:04
333-C0012C-14H-5,101.0111.845111.4921.113TC was replaced to the highest value.11.1132010-12-30T00:36:09
333-C0012C-14H-6,33.0112.575112.1541.148TC was replaced to the highest value.11.1482010-12-30T23:16:33
333-C0012C-14H-6,108.0113.325112.8351.010TC was replaced to the highest value.11.0102010-12-30T00:36:32
333-C0012C-14H-7,26.0113.915113.3711.093TC was replaced to the highest value.11.0932010-12-30T23:16:58
333-C0012C-14H-7,81.0114.465113.8711.074TC was replaced to the highest value.11.0742010-12-30T00:36:56
333-C0012C-14H-8,30.0115.355114.6791.073TC was replaced to the highest value.11.0732010-12-30T23:17:22
333-C0012C-14H-8,100.0116.055115.3141.12311.1232010-12-30T00:37:15
333-C0012C-15H-1,30.0116.300116.2341.111TC was replaced to the highest value.11.1112010-12-30T00:37:42
333-C0012C-15H-1,100.0117.000116.7801.12711.1272010-12-30T00:38:00
333-C0012C-15H-2,30.0117.720117.3421.135TC was replaced to the highest value.11.1352010-12-30T00:38:24
333-C0012C-15H-2,101.0118.430117.8961.129TC was replaced to the highest value.11.1292010-12-30T00:38:45
333-C0012C-15H-3,30.0119.135118.4471.143TC was replaced to the highest value.11.1432010-12-30T00:39:10
333-C0012C-15H-3,100.0119.835118.9931.111TC was replaced to the highest value.11.1112010-12-30T00:39:32
333-C0012C-15H-5,30.0120.870119.8011.112TC was replaced to the highest value.11.1122010-12-30T00:40:03
333-C0012C-15H-5,80.0121.370120.1911.087TC was replaced to the highest value.11.0872010-12-30T00:40:26
333-C0012C-15H-6,30.0122.290120.9091.078TC was replaced to the highest value.11.0782010-12-30T00:40:46
333-C0012C-15H-6,80.0122.790121.2991.001TC was replaced to the highest value.11.0012010-12-30T00:41:08
333-C0012C-15H-7,30.0123.330121.7211.085TC was replaced to the highest value.11.0852010-12-30T00:41:30
333-C0012C-15H-7,90.0123.930122.1890.983TC was replaced to the highest value.10.9832010-12-30T01:12:55
333-C0012C-15H-8,30.0124.340122.5091.076TC was replaced to the highest value.11.0762010-12-30T01:13:24
333-C0012C-15H-8,100.0125.040123.0551.050TC was replaced to the highest value.11.0502010-12-30T01:13:49