Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): XRF-core logger measurements from IODP Hole 333-C0011D [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.784914

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Coverage:
Latitude: 32.829060 * Longitude: 136.882083
Minimum DEPTH, sediment/rock: 25.440 m * Maximum DEPTH, sediment/rock: 378.940 m
Event(s):
333-C0011D * Latitude: 32.829060 * Longitude: 136.882083 * Elevation: -4050.5 m * Recovery: 351.49 m * Campaign: Exp333 (NanTroSEIZE Stage 2: Subduction Inputs 2 and Heat Flow) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 333 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 333 Scientists[m CSF-B] Top Core depth (below sea floor)
Aluminium oxideAl2O3%Expedition 333 ScientistsX-ray fluorescence (XRF)
Calcium oxideCaO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Iron oxide, Fe2O3Fe2O3%Expedition 333 ScientistsX-ray fluorescence (XRF)
Potassium oxideK2O%Expedition 333 ScientistsX-ray fluorescence (XRF)
Magnesium oxideMgO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Manganese oxideMnO%Expedition 333 ScientistsX-ray fluorescence (XRF)
10 Sodium oxideNa2O%Expedition 333 ScientistsX-ray fluorescence (XRF)
11 Phosphorus pentoxideP2O5%Expedition 333 ScientistsX-ray fluorescence (XRF)
12 Silicon dioxideSiO2%Expedition 333 ScientistsX-ray fluorescence (XRF)
13 Titanium dioxideTiO2%Expedition 333 ScientistsX-ray fluorescence (XRF)
14 Loss on ignitionLOI%Expedition 333 ScientistsMuffel furnace
15 Time StampTime StampExpedition 333 ScientistsXRF registration
Size:
728 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

Al2O3 [%]

CaO [%]

Fe2O3 [%]

K2O [%]

MgO [%]

MnO [%]
10 
Na2O [%]
11 
P2O5 [%]
12 
SiO2 [%]
13 
TiO2 [%]
14 
LOI [%]
15 
Time Stamp
333-C0011D-1H-4,21.025.44025.17616.7173.3805.7713.0172.4640.0723.4320.11262.8860.7076.5426170472010-12-28T06:15:50
333-C0011D-2H-5,21.036.15535.99915.2433.9926.5172.8032.5290.0693.5650.10662.8970.6317.2695163272010-12-28T06:15:51
333-C0011D-3H-5,22.545.28545.01713.6451.2052.2544.9990.3920.0604.1620.04377.1720.1534.8543689322010-12-28T06:15:51
333-C0011D-4H-5,21.552.90552.11115.5845.7715.6542.7212.2290.0753.3620.11062.0930.6357.9504353652010-12-28T06:15:51
333-C0011D-5H-5,21.061.14560.89516.3425.7565.9132.7692.4990.0733.3140.12060.9080.7208.0286857912010-12-28T06:15:51
333-C0011D-6H-4,22.569.22569.01415.4108.6555.7112.5932.2150.0913.2660.12159.7480.6689.6493827162010-12-24T17:24:53
333-C0011D-7H-4,21.078.92576.57016.4012.8745.8202.6242.2180.0723.5690.10763.7530.6835.5734359052010-12-28T06:15:56
333-C0011D-9H-3,21.084.56584.49216.6361.4736.7493.2022.6390.0573.1530.10462.6320.7156.0063478922010-12-28T06:15:56
333-C0011D-10H-5,22.096.10095.81516.4342.5236.4313.0012.4480.0713.5170.10162.4670.6976.4293758322010-12-28T06:15:49
333-C0011D-11H-5,23.0104.500104.37617.4141.6236.7493.1792.6660.0633.5950.10265.4100.7226.5002165712010-12-28T06:15:49
333-C0011D-12H-5,21.5114.700114.45517.0262.1176.1322.9412.3690.0723.4100.09362.9870.7136.3548585912010-12-28T06:15:49
333-C0011D-13H-5,23.5123.800121.85416.0151.5815.4753.0232.0000.0773.5490.07965.3960.5696.4977015782010-12-28T06:15:50
333-C0011D-14H-1,9.0125.090125.07812.9760.8592.5114.8010.3020.0633.8160.03972.5290.1105.0920261372011-01-04T13:15:16
333-C0011D-14H-5,23.0130.650129.92117.4341.2316.3343.3532.7490.0633.1820.09662.5760.7156.5059455942010-12-28T06:15:50
333-C0011D-15H-1,75.0134.250134.20413.3453.5134.6202.1500.9220.0944.0740.06172.6640.3146.8700058472011-01-04T13:15:17
333-C0011D-15H-4,22.5138.005137.72916.6932.8495.8993.1172.4800.0723.2890.09263.1660.6957.3712567842010-12-28T06:15:50
333-C0011D-17H-6,21.5155.945155.01316.9282.2655.9233.1382.4560.1073.1920.09662.9380.6836.9709211102010-12-28T06:15:50
333-C0011D-18H-4,22.5161.750161.59417.0551.5175.7973.1582.4230.0683.2340.09363.5720.7046.5530602262010-12-28T06:15:50
333-C0011D-19H-3,21.0171.045170.40317.1182.0916.0293.1322.5260.1043.1920.09262.4040.7007.0686731672010-12-28T06:15:50
333-C0011D-20H-4,21.0178.215178.00717.3982.8576.2643.1942.5480.1622.9910.11361.7230.7307.4478510432010-12-28T06:15:50
333-C0011D-21H-4,21.5183.750182.84218.0921.3836.6193.3782.7000.1132.9830.11061.9080.7366.5678491692010-12-28T06:15:50
333-C0011D-22H-1,54.5185.045184.63517.8291.2756.3503.3322.6280.1043.0000.10562.9300.7176.3601730482011-01-01T17:58:34
333-C0011D-23T-2,70.0188.105188.10517.5122.2856.0913.1742.5240.1003.1460.08862.0710.7046.9473353492011-01-01T17:58:35
333-C0011D-24T-1,41.0195.910195.91017.9461.8606.3013.3912.6720.0733.3340.09364.2890.7516.7031327702011-01-01T17:58:35
333-C0011D-25T-2,30.0201.155201.15517.5121.6726.2443.3572.5410.0653.0700.09462.6290.7356.7674175462010-12-28T06:15:50
333-C0011D-26X-3,31.5208.135206.88617.1863.3636.2263.2442.5010.0973.1650.09461.7150.6777.9329004332010-12-29T17:08:17
333-C0011D-27X-3,31.5213.160212.37218.3371.1896.6253.5492.8100.1242.9480.10261.6660.7726.7965339332010-12-29T17:08:20
333-C0011D-29X-4,32.0224.225223.59916.7714.0657.3522.8462.6520.1143.3070.09060.4650.7617.4256890652010-12-28T06:15:51
333-C0011D-30X-1,86.0225.860225.86017.1651.8196.1573.1612.5170.0783.3520.09062.6730.7116.3014442072011-01-01T17:58:37
333-C0011D-31X-4,30.0238.440238.44012.8486.76722.5972.2251.9290.2492.5950.09547.5030.53617.1816331102010-12-28T06:15:51
333-C0011D-32X-4,29.5244.900244.54716.6924.7587.6112.9312.4330.2463.2770.09759.3330.6819.3477811572010-12-28T06:15:51
333-C0011D-33X-3,31.5249.370249.16215.9222.3304.8353.0731.8280.1033.5680.07965.3250.5006.8525616642010-12-28T06:15:51
333-C0011D-34X-4,35.0256.115254.68317.1482.8326.0483.2782.3930.1822.6880.08763.0210.7146.6879621712010-12-29T17:08:23
333-C0011D-36X-5,35.0271.630271.30116.8825.0825.5803.2742.3980.1292.6750.09461.5380.6998.3007510342010-12-29T17:08:24
333-C0011D-37X-4,33.5280.035279.65517.5992.1376.2613.5022.6250.1932.5080.09662.3420.7366.1673003802010-12-29T17:08:26
333-C0011D-38X-3,36.0285.680285.68017.6571.0706.5883.5062.6370.1342.6040.08663.0600.7095.5377574372010-12-29T17:08:27
333-C0011D-39X-5,36.0297.620297.38817.4852.9306.2483.3792.5490.3292.4470.08761.8550.7316.9358122592010-12-29T17:08:29
333-C0011D-40X-5,41.0306.945306.64717.2163.8846.3443.2332.3610.2082.4550.08861.8010.6897.6004265912010-12-28T06:15:51
333-C0011D-41X-5,39.5316.765316.76517.7091.9646.0783.2612.2990.0862.4680.08163.5420.6965.7754865742010-12-29T17:08:32
333-C0011D-42X-6,37.0326.400326.09817.4892.3555.7953.2822.3860.1402.5410.09963.4560.7086.2394887322011-01-02T06:35:29
333-C0011D-43X-3,36.5332.660332.09417.0331.0736.5533.1982.5280.3042.4190.09363.1990.6905.5657055102010-12-29T17:08:34
333-C0011D-44X-4,39.0338.110337.53416.2792.4556.0133.3082.4030.3412.6160.08663.8600.6816.1330715922010-12-29T17:08:35
333-C0011D-44X-6,55.5339.305338.53817.7998.9405.5321.4822.1431.0163.0960.83256.6370.7237.5386229262011-01-04T13:15:17
333-C0011D-45X-3,39.5342.710342.44516.7541.3647.0323.2322.6040.1232.7010.08862.9720.6625.9316082332010-12-29T17:08:37
333-C0011D-46X-3,40.0347.310347.09216.3331.0916.2383.2912.4680.1122.5580.08265.1420.6595.0116382652010-12-29T17:08:38
333-C0011D-47X-4,51.0352.800352.00015.8822.8356.0433.2452.4060.1802.6570.08763.4410.6756.4861323432011-01-04T13:15:17
333-C0011D-47X-6,116.0354.415353.22415.6113.7244.9871.9051.8000.0953.4880.09266.2360.5114.3266475642011-01-04T13:15:17
333-C0011D-48X-3,39.0357.295356.81415.6081.6115.6713.1052.2780.7152.8690.08365.1260.6575.9060225022010-12-29T17:08:40
333-C0011D-49X-3,42.0362.775362.15716.1591.8396.0003.2052.3970.1152.6950.09964.8560.6625.5639233642010-12-29T17:08:41
333-C0011D-50X-4,57.0369.795369.18413.9053.8814.2211.6701.5490.0833.0980.08269.4210.4782.8030745032011-01-04T13:15:17
333-C0011D-51X-1,60.0370.600370.60014.2554.2835.0051.5961.7540.1033.1870.08868.3370.5482.8265405482011-01-04T13:15:17
333-C0011D-52X-4,38.0378.940378.94016.9833.4196.4283.2812.7090.1692.4560.10361.6320.6757.2936203152011-01-01T17:58:40