Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): Thermal conductivity of IODP Hole 333-C0011D [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.784899
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Other version:
IODP Hole 333-C0011D, snapshot taken on 2012-05-08, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/333/C0011D/
Project(s):
Coverage:
Latitude: 32.829060 * Longitude: 136.882083
Minimum DEPTH, sediment/rock: 21.300 m * Maximum DEPTH, sediment/rock: 379.760 m
Event(s):
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Expedition 333 Scientists | DSDP/ODP/IODP sample designation | ||
2 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
3 | Depth, top/min | Depth top | m | Expedition 333 Scientists | [m CSF-B] Top Core depth (below sea floor) | |
4 | Conductivity, thermal | k | W/m/K | Expedition 333 Scientists | Average | |
5 | Comment | Comment | Expedition 333 Scientists | Thermal conductivity measurement horizon comment | ||
6 | Number | No | Expedition 333 Scientists | Number of runs | ||
7 | Conductivity, thermal | k | W/m/K | Expedition 333 Scientists | Run 1 | |
8 | Conductivity, thermal | k | W/m/K | Expedition 333 Scientists | Run 2 | |
9 | Conductivity, thermal | k | W/m/K | Expedition 333 Scientists | Run 3 | |
10 | Comment | Comment | Expedition 333 Scientists | Thermal conductivity probe comment | ||
11 | Time Stamp | Time Stamp | Expedition 333 Scientists | Registration |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
4368 data points
Data
1 Sample label | 2 Depth sed [m] | 3 Depth top [m] ([m CSF-B] Top Core depth (bel...) | 4 k [W/m/K] (Average) | 5 Comment (Thermal conductivity measurem...) | 6 No (Number of runs) | 7 k [W/m/K] (Run 1) | 8 k [W/m/K] (Run 2) | 9 k [W/m/K] (Run 3) | 10 Comment (Thermal conductivity probe co...) | 11 Time Stamp (Registration) |
---|---|---|---|---|---|---|---|---|---|---|
333-C0011D-1H-1,30.0 | 21.300 | 21.282 | 0.993 | TC was replaced to the highest value. | 1 | 0.993 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:45:12 | ||
333-C0011D-1H-1,100.0 | 22.000 | 21.941 | 0.859 | 1 | 0.859 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:45:59 | |||
333-C0011D-1H-2,30.0 | 22.710 | 22.608 | 0.993 | TC was replaced to the highest value. | 1 | 0.993 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:48:40 | ||
333-C0011D-1H-2,100.0 | 23.410 | 23.267 | 1.027 | TC was replaced to the highest value. | 1 | 1.027 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:48:59 | ||
333-C0011D-1H-3,30.0 | 24.120 | 23.935 | 1.084 | TC was replaced to the highest value. | 1 | 1.084 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:49:28 | ||
333-C0011D-1H-3,100.0 | 24.820 | 24.593 | 1.087 | TC was replaced to the highest value. | 1 | 1.087 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:49:51 | ||
333-C0011D-1H-5,30.0 | 25.750 | 25.468 | 1.028 | TC was replaced to the highest value. | 1 | 1.028 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:50:13 | ||
333-C0011D-1H-5,100.0 | 26.450 | 26.126 | 1.008 | TC was replaced to the highest value. | 1 | 1.008 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:50:33 | ||
333-C0011D-1H-6,15.0 | 27.005 | 26.648 | 1.012 | TC was replaced to the highest value. | 1 | 1.012 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:50:54 | ||
333-C0011D-1H-7,30.0 | 27.375 | 26.996 | 1.008 | TC was replaced to the highest value. | 1 | 1.008 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:51:16 | ||
333-C0011D-1H-7,100.0 | 28.075 | 27.655 | 1.049 | TC was replaced to the highest value. | 1 | 1.049 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:51:41 | ||
333-C0011D-1H-8,30.0 | 28.570 | 28.120 | 0.946 | TC was replaced to the highest value. | 1 | 0.946 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:52:01 | ||
333-C0011D-1H-8,100.0 | 29.270 | 28.779 | 1.058 | TC was replaced to the highest value. | 1 | 1.058 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:52:22 | ||
333-C0011D-1H-9,30.0 | 29.990 | 29.456 | 1.017 | TC was replaced to the highest value. | 1 | 1.017 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:52:46 | ||
333-C0011D-1H-9,91.0 | 30.600 | 30.030 | 1.089 | TC was replaced to the highest value. | 1 | 1.089 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:53:14 | ||
333-C0011D-2H-1,30.0 | 30.800 | 30.792 | 1.056 | TC was replaced to the highest value. | 1 | 1.056 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:53:37 | ||
333-C0011D-2H-1,100.0 | 31.500 | 31.472 | 1.064 | 1 | 1.064 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:53:57 | |||
333-C0011D-2H-2,30.0 | 32.195 | 32.148 | 0.995 | TC was replaced to the highest value. | 1 | 0.995 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:54:22 | ||
333-C0011D-2H-2,90.0 | 32.795 | 32.732 | 1.037 | TC was replaced to the highest value. | 1 | 1.037 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:54:43 | ||
333-C0011D-2H-3,30.0 | 33.615 | 33.529 | 1.038 | TC was replaced to the highest value. | 1 | 1.038 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:55:09 | ||
333-C0011D-2H-3,100.0 | 34.315 | 34.210 | 1.081 | 1 | 1.081 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2011-01-04T12:56:05 | |||
333-C0011D-2H-4,30.0 | 35.035 | 34.910 | 1.055 | TC was replaced to the highest value. | 1 | 1.055 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:55:57 | ||
333-C0011D-2H-4,88.0 | 35.615 | 35.474 | 1.038 | TC was replaced to the highest value. | 1 | 1.038 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:56:18 | ||
333-C0011D-2H-7,30.0 | 36.695 | 36.524 | 1.056 | TC was replaced to the highest value. | 1 | 1.056 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:56:43 | ||
333-C0011D-2H-7,56.0 | 36.955 | 36.777 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:57:07 | ||
333-C0011D-2H-9,40.0 | 39.305 | 39.062 | 1.027 | TC was replaced to the highest value. | 1 | 1.027 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:57:28 | ||
333-C0011D-2H-9,77.0 | 39.675 | 39.421 | 1.034 | TC was replaced to the highest value. | 1 | 1.034 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:57:49 | ||
333-C0011D-3H-1,39.0 | 40.390 | 40.370 | 1.067 | TC was replaced to the highest value. | 1 | 1.067 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:58:12 | ||
333-C0011D-3H-1,100.0 | 41.000 | 40.949 | 1.011 | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:58:33 | |||
333-C0011D-3H-2,30.0 | 41.715 | 41.628 | 0.928 | TC was replaced to the highest value. | 1 | 0.928 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:58:59 | ||
333-C0011D-3H-2,100.0 | 42.415 | 42.293 | 1.066 | TC was replaced to the highest value. | 1 | 1.066 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:59:16 | ||
333-C0011D-3H-3,37.0 | 43.195 | 43.033 | 1.055 | TC was replaced to the highest value. | 1 | 1.055 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T00:59:41 | ||
333-C0011D-3H-3,100.0 | 43.825 | 43.631 | 0.832 | 1 | 0.832 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:00:03 | |||
333-C0011D-3H-4,23.0 | 44.475 | 44.248 | 1.009 | TC was replaced to the highest value. | 1 | 1.009 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:00:27 | ||
333-C0011D-3H-4,67.0 | 44.915 | 44.666 | 1.002 | TC was replaced to the highest value. | 1 | 1.002 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:00:53 | ||
333-C0011D-3H-6,30.0 | 45.595 | 45.312 | 1.059 | TC was replaced to the highest value. | 1 | 1.059 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:01:13 | ||
333-C0011D-3H-6,100.0 | 46.295 | 45.976 | 0.910 | TC was replaced to the highest value. | 1 | 0.910 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:01:32 | ||
333-C0011D-3H-7,30.0 | 47.015 | 46.660 | 1.028 | TC was replaced to the highest value. | 1 | 1.028 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:01:52 | ||
333-C0011D-3H-7,100.0 | 47.715 | 47.324 | 1.014 | TC was replaced to the highest value. | 1 | 1.014 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:02:11 | ||
333-C0011D-3H-8,22.0 | 48.360 | 47.937 | 1.008 | TC was replaced to the highest value. | 1 | 1.008 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:02:34 | ||
333-C0011D-3H-8,82.0 | 48.960 | 48.506 | 1.058 | TC was replaced to the highest value. | 1 | 1.058 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:02:56 | ||
333-C0011D-4H-1,30.0 | 49.300 | 49.239 | 0.965 | TC was replaced to the highest value. | 1 | 0.965 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:03:20 | ||
333-C0011D-4H-1,100.0 | 50.000 | 49.797 | 0.955 | TC was replaced to the highest value. | 1 | 0.955 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:03:41 | ||
333-C0011D-4H-2,30.0 | 50.715 | 50.366 | 1.039 | TC was replaced to the highest value. | 1 | 1.039 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:04:02 | ||
333-C0011D-4H-2,100.0 | 51.415 | 50.924 | 0.871 | TC was replaced to the highest value. | 1 | 0.871 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:04:53 | ||
333-C0011D-4H-3,21.0 | 52.045 | 51.426 | 1.031 | TC was replaced to the highest value. | 1 | 1.031 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:05:16 | ||
333-C0011D-4H-4,13.0 | 52.585 | 51.856 | 0.999 | TC was replaced to the highest value. | 1 | 0.999 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:05:37 | ||
333-C0011D-4H-6,30.0 | 53.215 | 52.357 | 1.027 | TC was replaced to the highest value. | 1 | 1.027 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:05:58 | ||
333-C0011D-4H-6,100.0 | 53.915 | 52.915 | 0.988 | TC was replaced to the highest value. | 1 | 0.988 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:06:17 | ||
333-C0011D-4H-7,30.0 | 54.410 | 53.309 | 0.958 | TC was replaced to the highest value. | 1 | 0.958 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:06:37 | ||
333-C0011D-4H-7,101.0 | 55.120 | 53.875 | 0.965 | 1 | 0.965 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:07:05 | |||
333-C0011D-4H-8,32.0 | 55.845 | 54.452 | 0.973 | TC was replaced to the highest value. | 1 | 0.973 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:07:32 | ||
333-C0011D-4H-8,94.0 | 56.465 | 54.946 | 0.843 | 1 | 0.843 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:07:59 | |||
333-C0011D-5H-1,30.0 | 55.800 | 55.787 | 0.961 | TC was replaced to the highest value. | 1 | 0.961 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:08:26 | ||
333-C0011D-5H-1,100.0 | 56.500 | 56.456 | 0.951 | TC was replaced to the highest value. | 1 | 0.951 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:08:46 | ||
333-C0011D-5H-2,30.0 | 57.205 | 57.130 | 0.998 | TC was replaced to the highest value. | 1 | 0.998 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:09:08 | ||
333-C0011D-5H-2,100.0 | 57.905 | 57.799 | 1.000 | TC was replaced to the highest value. | 1 | 1.000 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:09:32 | ||
333-C0011D-5H-3,30.0 | 58.615 | 58.477 | 0.930 | TC was replaced to the highest value. | 1 | 0.930 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:09:59 | ||
333-C0011D-5H-3,100.0 | 59.315 | 59.146 | 0.993 | TC was replaced to the highest value. | 1 | 0.993 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:10:20 | ||
333-C0011D-5H-4,37.0 | 60.090 | 59.887 | 0.970 | TC was replaced to the highest value. | 1 | 0.970 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:10:50 | ||
333-C0011D-5H-4,100.0 | 60.720 | 60.489 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:11:10 | ||
333-C0011D-5H-6,30.0 | 61.455 | 61.191 | 0.981 | TC was replaced to the highest value. | 1 | 0.981 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:11:32 | ||
333-C0011D-5H-6,100.0 | 62.155 | 61.860 | 0.970 | TC was replaced to the highest value. | 1 | 0.970 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:12:01 | ||
333-C0011D-5H-7,31.0 | 62.880 | 62.553 | 0.997 | TC was replaced to the highest value. | 1 | 0.997 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:12:23 | ||
333-C0011D-5H-7,83.0 | 63.400 | 63.050 | 0.989 | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:12:47 | |||
333-C0011D-5H-8,30.0 | 64.275 | 63.887 | 0.971 | TC was replaced to the highest value. | 1 | 0.971 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:13:09 | ||
333-C0011D-5H-8,80.0 | 64.775 | 64.364 | 0.971 | TC was replaced to the highest value. | 1 | 0.971 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:13:31 | ||
333-C0011D-6H-1,40.0 | 65.400 | 65.380 | 0.945 | TC was replaced to the highest value. | 1 | 0.945 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:13:53 | ||
333-C0011D-6H-1,100.0 | 66.000 | 65.950 | 0.945 | TC was replaced to the highest value. | 1 | 0.945 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:14:12 | ||
333-C0011D-6H-2,30.0 | 66.715 | 66.629 | 0.933 | TC was replaced to the highest value. | 1 | 0.933 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:14:33 | ||
333-C0011D-6H-2,100.0 | 67.415 | 67.294 | 0.783 | 1 | 0.783 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:14:58 | |||
333-C0011D-6H-3,30.0 | 68.120 | 67.964 | 0.947 | TC was replaced to the highest value. | 1 | 0.947 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:15:23 | ||
333-C0011D-6H-3,57.0 | 68.390 | 68.220 | 0.895 | TC was replaced to the highest value. | 1 | 0.895 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:15:44 | ||
333-C0011D-6H-5,30.0 | 69.535 | 69.308 | 0.955 | TC was replaced to the highest value. | 1 | 0.955 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:16:05 | ||
333-C0011D-6H-5,100.0 | 70.235 | 69.973 | 0.967 | TC was replaced to the highest value. | 1 | 0.967 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:16:23 | ||
333-C0011D-6H-6,30.0 | 70.945 | 70.648 | 0.800 | TC was replaced to the highest value. | 1 | 0.800 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:16:46 | ||
333-C0011D-6H-6,107.0 | 71.715 | 71.379 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:17:12 | ||
333-C0011D-6H-7,30.0 | 72.360 | 71.992 | 1.036 | TC was replaced to the highest value. | 1 | 1.036 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:17:35 | ||
333-C0011D-6H-7,100.0 | 73.060 | 72.657 | 1.034 | TC was replaced to the highest value. | 1 | 1.034 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:17:54 | ||
333-C0011D-6H-8,30.0 | 73.780 | 73.341 | 1.015 | TC was replaced to the highest value. | 1 | 1.015 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:18:16 | ||
333-C0011D-6H-8,100.0 | 74.480 | 74.006 | 0.922 | TC was replaced to the highest value. | 1 | 0.922 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:18:34 | ||
333-C0011D-7H-1,30.0 | 74.800 | 74.640 | 0.885 | TC was replaced to the highest value. | 1 | 0.885 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:19:00 | ||
333-C0011D-7H-1,100.0 | 75.500 | 74.968 | 0.959 | TC was replaced to the highest value. | 1 | 0.959 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:19:17 | ||
333-C0011D-7H-2,30.0 | 76.195 | 75.293 | 0.973 | TC was replaced to the highest value. | 1 | 0.973 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:19:36 | ||
333-C0011D-7H-2,100.0 | 76.895 | 75.620 | 1.065 | TC was replaced to the highest value. | 1 | 1.065 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:19:54 | ||
333-C0011D-7H-3,30.0 | 77.605 | 75.952 | 0.943 | TC was replaced to the highest value. | 1 | 0.943 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:20:19 | ||
333-C0011D-7H-3,100.0 | 78.305 | 76.280 | 0.994 | TC was replaced to the highest value. | 1 | 0.994 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:20:38 | ||
333-C0011D-7H-5,30.0 | 79.235 | 76.715 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:21:02 | ||
333-C0011D-7H-5,71.0 | 79.645 | 76.907 | 0.988 | TC was replaced to the highest value. | 1 | 0.988 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:21:22 | ||
333-C0011D-7H-6,30.0 | 80.435 | 77.276 | 0.986 | TC was replaced to the highest value. | 1 | 0.986 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:21:45 | ||
333-C0011D-7H-6,100.0 | 81.135 | 77.604 | 0.968 | TC was replaced to the highest value. | 1 | 0.968 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:22:03 | ||
333-C0011D-7H-7,30.0 | 81.855 | 77.940 | 0.973 | TC was replaced to the highest value. | 1 | 0.973 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:22:25 | ||
333-C0011D-7H-7,106.0 | 82.615 | 78.296 | 1.036 | TC was replaced to the highest value. | 1 | 1.036 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:22:45 | ||
333-C0011D-7H-8,23.0 | 83.190 | 78.565 | 0.951 | TC was replaced to the highest value. | 1 | 0.951 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:23:06 | ||
333-C0011D-7H-8,57.0 | 83.530 | 78.724 | 0.974 | TC was replaced to the highest value. | 1 | 0.974 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:23:31 | ||
333-C0011D-8H-1,30.0 | 79.300 | 79.087 | 0.939 | TC was replaced to the highest value. | 1 | 0.939 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:23:53 | ||
333-C0011D-8H-1,100.0 | 80.000 | 79.291 | 0.896 | TC was replaced to the highest value. | 1 | 0.896 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:24:14 | ||
333-C0011D-8H-2,30.0 | 80.710 | 79.498 | 0.978 | TC was replaced to the highest value. | 1 | 0.978 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:24:34 | ||
333-C0011D-8H-2,68.0 | 81.090 | 79.609 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:24:58 | ||
333-C0011D-9H-1,30.0 | 81.800 | 81.793 | 0.945 | TC was replaced to the highest value. | 1 | 0.945 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:25:35 | ||
333-C0011D-9H-1,100.0 | 82.500 | 82.476 | 0.979 | TC was replaced to the highest value. | 1 | 0.979 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:25:56 | ||
333-C0011D-9H-2,30.0 | 83.200 | 83.159 | 0.966 | TC was replaced to the highest value. | 1 | 0.966 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:26:17 | ||
333-C0011D-9H-2,100.0 | 83.900 | 83.843 | 1.043 | 1 | 1.043 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:26:40 | |||
333-C0011D-9H-4,27.0 | 84.845 | 84.765 | 0.996 | TC was replaced to the highest value. | 1 | 0.996 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:27:02 | ||
333-C0011D-9H-4,80.0 | 85.375 | 85.283 | 0.894 | TC was replaced to the highest value. | 1 | 0.894 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:27:22 | ||
333-C0011D-9H-5,50.0 | 85.990 | 85.883 | 0.938 | TC was replaced to the highest value. | 1 | 0.938 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:28:20 | ||
333-C0011D-9H-5,100.0 | 86.490 | 86.371 | 0.978 | TC was replaced to the highest value. | 1 | 0.978 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:28:38 | ||
333-C0011D-9H-6,18.0 | 87.080 | 86.947 | 1.029 | TC was replaced to the highest value. | 1 | 1.029 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:29:03 | ||
333-C0011D-9H-6,100.0 | 87.900 | 87.747 | 0.958 | TC was replaced to the highest value. | 1 | 0.958 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:29:25 | ||
333-C0011D-9H-7,30.0 | 88.595 | 88.426 | 0.958 | TC was replaced to the highest value. | 1 | 0.958 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:29:49 | ||
333-C0011D-9H-7,97.0 | 89.265 | 89.080 | 0.957 | TC was replaced to the highest value. | 1 | 0.957 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:30:12 | ||
333-C0011D-9H-8,20.0 | 89.715 | 89.519 | 0.997 | TC was replaced to the highest value. | 1 | 0.997 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:30:37 | ||
333-C0011D-9H-8,70.0 | 90.215 | 90.007 | 0.954 | TC was replaced to the highest value. | 1 | 0.954 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-22T01:30:58 | ||
333-C0011D-10H-1,36.0 | 90.860 | 90.842 | 0.936 | TC was replaced to the highest value. | 1 | 0.936 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:08:24 | ||
333-C0011D-10H-1,105.0 | 91.550 | 91.496 | 0.978 | TC was replaced to the highest value. | 1 | 0.978 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:08:45 | ||
333-C0011D-10H-2,30.0 | 92.180 | 92.094 | 0.915 | TC was replaced to the highest value. | 1 | 0.915 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:09:08 | ||
333-C0011D-10H-2,100.0 | 92.880 | 92.759 | 0.968 | TC was replaced to the highest value. | 1 | 0.968 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:09:27 | ||
333-C0011D-10H-3,30.0 | 93.595 | 93.437 | 0.948 | TC was replaced to the highest value. | 1 | 0.948 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:09:51 | ||
333-C0011D-10H-3,100.0 | 94.295 | 94.102 | 0.960 | TC was replaced to the highest value. | 1 | 0.960 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:10:09 | ||
333-C0011D-10H-4,30.0 | 94.990 | 94.761 | 0.941 | TC was replaced to the highest value. | 1 | 0.941 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:10:29 | ||
333-C0011D-10H-4,100.0 | 95.690 | 95.426 | 1.015 | TC was replaced to the highest value. | 1 | 1.015 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:10:49 | ||
333-C0011D-10H-6,30.0 | 96.410 | 96.109 | 0.951 | TC was replaced to the highest value. | 1 | 0.951 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:11:10 | ||
333-C0011D-10H-6,100.0 | 97.110 | 96.773 | 0.998 | TC was replaced to the highest value. | 1 | 0.998 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:11:29 | ||
333-C0011D-10H-7,30.0 | 97.815 | 97.442 | 0.937 | TC was replaced to the highest value. | 1 | 0.937 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:11:50 | ||
333-C0011D-10H-7,85.0 | 98.365 | 97.964 | 0.969 | TC was replaced to the highest value. | 1 | 0.969 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:12:13 | ||
333-C0011D-10H-8,30.0 | 99.225 | 98.781 | 0.997 | TC was replaced to the highest value. | 1 | 0.997 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:12:38 | ||
333-C0011D-10H-8,100.0 | 99.925 | 99.445 | 0.993 | TC was replaced to the highest value. | 1 | 0.993 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:12:59 | ||
333-C0011D-10H-CC,30.0 | 100.390 | 99.886 | 0.959 | TC was replaced to the highest value. | 1 | 0.959 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:13:26 | ||
333-C0011D-11H-1,30.0 | 100.300 | 100.292 | 0.968 | TC was replaced to the highest value. | 1 | 0.968 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:14:23 | ||
333-C0011D-11H-1,100.0 | 101.000 | 100.972 | 1.038 | TC was replaced to the highest value. | 1 | 1.038 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:14:41 | ||
333-C0011D-11H-2,30.0 | 101.720 | 101.673 | 1.052 | TC was replaced to the highest value. | 1 | 1.052 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:15:02 | ||
333-C0011D-11H-2,100.0 | 102.420 | 102.353 | 1.053 | 1 | 1.053 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:15:40 | |||
333-C0011D-11H-3,30.0 | 103.140 | 103.053 | 1.003 | TC was replaced to the highest value. | 1 | 1.003 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:16:04 | ||
333-C0011D-11H-3,85.0 | 103.690 | 103.588 | 0.948 | 1 | 0.948 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:16:24 | |||
333-C0011D-11H-4,15.0 | 104.195 | 104.079 | 0.980 | TC was replaced to the highest value. | 1 | 0.980 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:16:46 | ||
333-C0011D-11H-6,30.0 | 104.810 | 104.677 | 1.004 | TC was replaced to the highest value. | 1 | 1.004 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:17:07 | ||
333-C0011D-11H-6,90.0 | 105.410 | 105.260 | 0.994 | TC was replaced to the highest value. | 1 | 0.994 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:17:27 | ||
333-C0011D-11H-7,30.0 | 106.230 | 106.058 | 1.009 | TC was replaced to the highest value. | 1 | 1.009 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:17:49 | ||
333-C0011D-11H-7,100.0 | 106.930 | 106.739 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:18:08 | ||
333-C0011D-11H-8,30.0 | 107.655 | 107.443 | 0.970 | TC was replaced to the highest value. | 1 | 0.970 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:18:30 | ||
333-C0011D-11H-8,100.0 | 108.355 | 108.124 | 0.985 | TC was replaced to the highest value. | 1 | 0.985 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:18:49 | ||
333-C0011D-11H-9,30.0 | 109.075 | 108.824 | 1.008 | TC was replaced to the highest value. | 1 | 1.008 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:19:21 | ||
333-C0011D-11H-9,75.0 | 109.525 | 109.262 | 1.021 | TC was replaced to the highest value. | 1 | 1.021 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:19:50 | ||
333-C0011D-12H-1,30.0 | 109.800 | 109.786 | 0.981 | TC was replaced to the highest value. | 1 | 0.981 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:21:07 | ||
333-C0011D-12H-1,100.0 | 110.500 | 110.453 | 0.932 | TC was replaced to the highest value. | 1 | 0.932 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:21:28 | ||
333-C0011D-12H-2,30.0 | 111.165 | 111.087 | 0.964 | TC was replaced to the highest value. | 1 | 0.964 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:21:48 | ||
333-C0011D-12H-2,100.0 | 111.865 | 111.754 | 0.968 | TC was replaced to the highest value. | 1 | 0.968 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:22:45 | ||
333-C0011D-12H-3,30.0 | 112.575 | 112.430 | 1.012 | TC was replaced to the highest value. | 1 | 1.012 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:23:07 | ||
333-C0011D-12H-3,100.0 | 113.275 | 113.097 | 0.916 | TC was replaced to the highest value. | 1 | 0.916 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:23:26 | ||
333-C0011D-12H-4,31.0 | 113.990 | 113.778 | 0.996 | TC was replaced to the highest value. | 1 | 0.996 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:23:47 | ||
333-C0011D-12H-4,70.0 | 114.380 | 114.150 | 0.985 | TC was replaced to the highest value. | 1 | 0.985 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:24:07 | ||
333-C0011D-12H-6,30.0 | 115.010 | 114.750 | 0.924 | TC was replaced to the highest value. | 1 | 0.924 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:24:27 | ||
333-C0011D-12H-6,100.0 | 115.710 | 115.417 | 0.988 | TC was replaced to the highest value. | 1 | 0.988 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:24:45 | ||
333-C0011D-12H-7,30.0 | 116.425 | 116.099 | 0.962 | TC was replaced to the highest value. | 1 | 0.962 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:25:07 | ||
333-C0011D-12H-7,100.0 | 117.125 | 116.766 | 0.989 | TC was replaced to the highest value. | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:25:25 | ||
333-C0011D-12H-8,30.0 | 117.885 | 117.490 | 0.981 | TC was replaced to the highest value. | 1 | 0.981 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:25:52 | ||
333-C0011D-12H-8,95.0 | 118.535 | 118.109 | 0.974 | TC was replaced to the highest value. | 1 | 0.974 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:26:11 | ||
333-C0011D-13H-1,30.0 | 119.300 | 119.178 | 0.950 | TC was replaced to the highest value. | 1 | 0.950 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:26:31 | ||
333-C0011D-13H-1,100.0 | 120.000 | 119.595 | 0.976 | TC was replaced to the highest value. | 1 | 0.976 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:26:51 | ||
333-C0011D-13H-2,30.0 | 120.725 | 120.026 | 1.023 | TC was replaced to the highest value. | 1 | 1.023 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:27:10 | ||
333-C0011D-13H-2,100.0 | 121.425 | 120.442 | 0.955 | TC was replaced to the highest value. | 1 | 0.955 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:27:28 | ||
333-C0011D-13H-3,21.0 | 122.050 | 120.814 | 0.951 | TC was replaced to the highest value. | 1 | 0.951 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:27:48 | ||
333-C0011D-13H-3,62.0 | 122.460 | 121.058 | 0.959 | TC was replaced to the highest value. | 1 | 0.959 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:28:11 | ||
333-C0011D-13H-4,21.0 | 123.060 | 121.414 | 0.963 | TC was replaced to the highest value. | 1 | 0.963 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:28:34 | ||
333-C0011D-13H-4,49.0 | 123.340 | 121.581 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:28:55 | ||
333-C0011D-13H-6,30.0 | 124.110 | 122.039 | 0.950 | TC was replaced to the highest value. | 1 | 0.950 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:29:16 | ||
333-C0011D-13H-6,100.0 | 124.810 | 122.455 | 1.002 | TC was replaced to the highest value. | 1 | 1.002 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:29:59 | ||
333-C0011D-13H-7,30.0 | 125.530 | 122.883 | 0.989 | TC was replaced to the highest value. | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:30:18 | ||
333-C0011D-13H-7,100.0 | 126.230 | 123.299 | 0.994 | TC was replaced to the highest value. | 1 | 0.994 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:30:39 | ||
333-C0011D-13H-8,30.0 | 126.950 | 123.728 | 0.955 | TC was replaced to the highest value. | 1 | 0.955 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:31:00 | ||
333-C0011D-13H-8,100.0 | 127.650 | 124.144 | 0.945 | TC was replaced to the highest value. | 1 | 0.945 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:31:19 | ||
333-C0011D-13H-9,20.0 | 128.260 | 124.506 | 0.958 | TC was replaced to the highest value. | 1 | 0.958 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:31:39 | ||
333-C0011D-13H-9,56.0 | 128.620 | 124.720 | 0.982 | TC was replaced to the highest value. | 1 | 0.982 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:32:00 | ||
333-C0011D-14H-1,30.0 | 125.300 | 125.261 | 0.927 | TC was replaced to the highest value. | 1 | 0.927 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:32:24 | ||
333-C0011D-14H-1,100.0 | 126.000 | 125.871 | 0.891 | TC was replaced to the highest value. | 1 | 0.891 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:32:43 | ||
333-C0011D-14H-2,30.0 | 126.705 | 126.485 | 0.894 | TC was replaced to the highest value. | 1 | 0.894 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:33:04 | ||
333-C0011D-14H-2,100.0 | 127.405 | 127.094 | 0.990 | TC was replaced to the highest value. | 1 | 0.990 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:33:21 | ||
333-C0011D-14H-3,30.0 | 128.115 | 127.713 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:33:42 | ||
333-C0011D-14H-3,100.0 | 128.815 | 128.322 | 0.935 | TC was replaced to the highest value. | 1 | 0.935 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:34:02 | ||
333-C0011D-14H-4,30.0 | 129.525 | 128.941 | 0.981 | TC was replaced to the highest value. | 1 | 0.981 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:34:20 | ||
333-C0011D-14H-4,100.0 | 130.225 | 129.551 | 1.000 | TC was replaced to the highest value. | 1 | 1.000 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:34:38 | ||
333-C0011D-14H-6,30.0 | 130.960 | 130.191 | 1.043 | TC was replaced to the highest value. | 1 | 1.043 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:34:58 | ||
333-C0011D-14H-6,100.0 | 131.660 | 130.800 | 0.994 | TC was replaced to the highest value. | 1 | 0.994 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:35:17 | ||
333-C0011D-14H-7,30.0 | 132.400 | 131.445 | 1.056 | TC was replaced to the highest value. | 1 | 1.056 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:35:38 | ||
333-C0011D-14H-7,100.0 | 133.100 | 132.054 | 0.978 | TC was replaced to the highest value. | 1 | 0.978 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:35:57 | ||
333-C0011D-14H-8,24.0 | 133.750 | 132.620 | 0.986 | TC was replaced to the highest value. | 1 | 0.986 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:36:20 | ||
333-C0011D-14H-8,74.0 | 134.250 | 133.056 | 1.028 | TC was replaced to the highest value. | 1 | 1.028 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:36:41 | ||
333-C0011D-15H-1,30.0 | 133.800 | 133.782 | 1.018 | TC was replaced to the highest value. | 1 | 1.018 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:37:02 | ||
333-C0011D-15H-1,100.0 | 134.500 | 134.439 | 1.035 | TC was replaced to the highest value. | 1 | 1.035 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:37:19 | ||
333-C0011D-15H-2,30.0 | 135.220 | 135.115 | 0.959 | TC was replaced to the highest value. | 1 | 0.959 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:37:39 | ||
333-C0011D-15H-2,101.0 | 135.930 | 135.781 | 0.958 | TC was replaced to the highest value. | 1 | 0.958 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:38:02 | ||
333-C0011D-15H-3,30.0 | 136.650 | 136.457 | 0.976 | TC was replaced to the highest value. | 1 | 0.976 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:38:24 | ||
333-C0011D-15H-3,100.0 | 137.350 | 137.114 | 0.965 | TC was replaced to the highest value. | 1 | 0.965 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:38:44 | ||
333-C0011D-15H-5,30.0 | 138.315 | 138.020 | 0.972 | TC was replaced to the highest value. | 1 | 0.972 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:39:04 | ||
333-C0011D-15H-5,89.0 | 138.905 | 138.574 | 1.014 | TC was replaced to the highest value. | 1 | 1.014 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:39:27 | ||
333-C0011D-15H-6,30.0 | 139.740 | 139.358 | 0.957 | TC was replaced to the highest value. | 1 | 0.957 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:39:48 | ||
333-C0011D-15H-6,100.0 | 140.440 | 140.015 | 0.952 | TC was replaced to the highest value. | 1 | 0.952 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:40:05 | ||
333-C0011D-15H-7,30.0 | 141.165 | 140.695 | 0.974 | TC was replaced to the highest value. | 1 | 0.974 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:40:26 | ||
333-C0011D-15H-7,100.0 | 141.865 | 141.352 | 1.005 | TC was replaced to the highest value. | 1 | 1.005 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:40:43 | ||
333-C0011D-15H-8,17.0 | 142.450 | 141.902 | 0.989 | TC was replaced to the highest value. | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:41:07 | ||
333-C0011D-15H-8,33.0 | 142.610 | 142.052 | 0.990 | TC was replaced to the highest value. | 1 | 0.990 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:41:32 | ||
333-C0011D-16H-1,30.0 | 143.300 | 143.286 | 0.947 | TC was replaced to the highest value. | 1 | 0.947 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:41:55 | ||
333-C0011D-16H-1,115.0 | 144.150 | 144.097 | 0.911 | TC was replaced to the highest value. | 1 | 0.911 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:42:17 | ||
333-C0011D-16H-3,30.0 | 144.875 | 144.788 | 0.947 | TC was replaced to the highest value. | 1 | 0.947 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:42:35 | ||
333-C0011D-16H-3,80.0 | 145.375 | 145.265 | 0.989 | TC was replaced to the highest value. | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:43:00 | ||
333-C0011D-16H-4,24.0 | 145.820 | 145.689 | 0.962 | TC was replaced to the highest value. | 1 | 0.962 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:43:20 | ||
333-C0011D-16H-4,62.0 | 146.200 | 146.052 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:43:40 | ||
333-C0011D-16H-5,30.0 | 146.695 | 146.524 | 0.926 | TC was replaced to the highest value. | 1 | 0.926 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:44:01 | ||
333-C0011D-16H-5,105.0 | 147.445 | 147.239 | 0.893 | TC was replaced to the highest value. | 1 | 0.893 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:44:21 | ||
333-C0011D-16H-6,30.0 | 148.110 | 147.873 | 0.941 | TC was replaced to the highest value. | 1 | 0.941 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:44:42 | ||
333-C0011D-16H-6,100.0 | 148.810 | 148.541 | 0.895 | TC was replaced to the highest value. | 1 | 0.895 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:45:05 | ||
333-C0011D-16H-7,24.0 | 149.455 | 149.156 | 1.017 | TC was replaced to the highest value. | 1 | 1.017 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:45:26 | ||
333-C0011D-16H-7,57.0 | 149.785 | 149.471 | 1.011 | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:45:47 | |||
333-C0011D-17H-1,30.0 | 150.300 | 150.253 | 0.960 | 1 | 0.960 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:17:33 | |||
333-C0011D-17H-1,100.0 | 151.000 | 150.843 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:46:28 | ||
333-C0011D-17H-2,30.0 | 151.730 | 151.459 | 0.970 | TC was replaced to the highest value. | 1 | 0.970 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:46:50 | ||
333-C0011D-17H-2,105.0 | 152.480 | 152.091 | 1.011 | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:47:10 | |||
333-C0011D-17H-3,30.0 | 153.155 | 152.661 | 0.993 | TC was replaced to the highest value. | 1 | 0.993 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:47:30 | ||
333-C0011D-17H-3,100.0 | 153.855 | 153.251 | 1.032 | TC was replaced to the highest value. | 1 | 1.032 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:47:52 | ||
333-C0011D-17H-4,16.0 | 154.220 | 153.559 | 0.972 | TC was replaced to the highest value. | 1 | 0.972 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:48:12 | ||
333-C0011D-17H-5,30.0 | 154.605 | 153.883 | 1.001 | TC was replaced to the highest value. | 1 | 1.001 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:48:33 | ||
333-C0011D-17H-5,86.0 | 155.165 | 154.355 | 1.021 | TC was replaced to the highest value. | 1 | 1.021 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:48:54 | ||
333-C0011D-17H-7,22.0 | 156.175 | 155.207 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:49:18 | ||
333-C0011D-17H-7,57.0 | 156.525 | 155.502 | 1.001 | TC was replaced to the highest value. | 1 | 1.001 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:49:40 | ||
333-C0011D-17H-8,30.0 | 157.465 | 156.295 | 0.924 | TC was replaced to the highest value. | 1 | 0.924 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:50:01 | ||
333-C0011D-17H-8,90.0 | 158.065 | 156.801 | 1.032 | 1 | 1.032 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:50:21 | |||
333-C0011D-17H-9,30.0 | 158.880 | 157.488 | 1.016 | TC was replaced to the highest value. | 1 | 1.016 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:25:29 | ||
333-C0011D-17H-9,100.0 | 159.580 | 158.078 | 0.989 | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:25:46 | |||
333-C0011D-18H-1,14.0 | 158.640 | 158.633 | 0.960 | TC was replaced to the highest value. | 1 | 0.960 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:54:21 | ||
333-C0011D-18H-2,30.0 | 159.010 | 158.986 | 0.994 | TC was replaced to the highest value. | 1 | 0.994 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2011-01-04T12:57:46 | ||
333-C0011D-18H-2,100.0 | 159.710 | 159.652 | 1.015 | TC was replaced to the highest value. | 1 | 1.015 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:54:40 | ||
333-C0011D-18H-3,30.0 | 160.415 | 160.323 | 0.966 | TC was replaced to the highest value. | 1 | 0.966 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:55:02 | ||
333-C0011D-18H-3,100.0 | 161.115 | 160.989 | 1.007 | TC was replaced to the highest value. | 1 | 1.007 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:55:22 | ||
333-C0011D-18H-5,30.0 | 162.060 | 161.889 | 1.009 | TC was replaced to the highest value. | 1 | 1.009 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:55:42 | ||
333-C0011D-18H-5,100.0 | 162.760 | 162.555 | 0.981 | TC was replaced to the highest value. | 1 | 0.981 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:56:01 | ||
333-C0011D-18H-6,30.0 | 163.475 | 163.236 | 0.996 | TC was replaced to the highest value. | 1 | 0.996 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:56:21 | ||
333-C0011D-18H-6,100.0 | 164.175 | 163.902 | 0.966 | TC was replaced to the highest value. | 1 | 0.966 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:57:52 | ||
333-C0011D-18H-7,30.0 | 164.895 | 164.587 | 0.967 | TC was replaced to the highest value. | 1 | 0.967 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:58:12 | ||
333-C0011D-18H-7,100.0 | 165.595 | 165.254 | 1.003 | TC was replaced to the highest value. | 1 | 1.003 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:58:31 | ||
333-C0011D-18H-8,30.0 | 166.310 | 165.934 | 1.017 | TC was replaced to the highest value. | 1 | 1.017 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:58:52 | ||
333-C0011D-18H-8,100.0 | 167.010 | 166.601 | 1.011 | TC was replaced to the highest value. | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:59:11 | ||
333-C0011D-18H-9,14.0 | 167.550 | 167.115 | 0.981 | TC was replaced to the highest value. | 1 | 0.981 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T00:59:41 | ||
333-C0011D-19H-1,30.0 | 168.300 | 168.237 | 0.952 | TC was replaced to the highest value. | 1 | 0.952 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:00:01 | ||
333-C0011D-19H-1,100.0 | 169.000 | 168.789 | 0.983 | TC was replaced to the highest value. | 1 | 0.983 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:00:17 | ||
333-C0011D-19H-2,35.0 | 169.755 | 169.385 | 0.994 | TC was replaced to the highest value. | 1 | 0.994 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:19:01 | ||
333-C0011D-19H-2,100.0 | 170.405 | 169.898 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:19:23 | ||
333-C0011D-19H-4,30.0 | 171.355 | 170.648 | 0.987 | TC was replaced to the highest value. | 1 | 0.987 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:01:47 | ||
333-C0011D-19H-4,100.0 | 172.055 | 171.200 | 0.990 | TC was replaced to the highest value. | 1 | 0.990 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:02:03 | ||
333-C0011D-19H-5,30.0 | 172.785 | 171.776 | 1.000 | TC was replaced to the highest value. | 1 | 1.000 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:02:25 | ||
333-C0011D-19H-5,90.0 | 173.385 | 172.250 | 0.990 | TC was replaced to the highest value. | 1 | 0.990 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:02:45 | ||
333-C0011D-19H-6,30.0 | 174.190 | 172.885 | 1.006 | TC was replaced to the highest value. | 1 | 1.006 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:03:03 | ||
333-C0011D-19H-6,100.0 | 174.890 | 173.437 | 0.990 | TC was replaced to the highest value. | 1 | 0.990 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:03:20 | ||
333-C0011D-19H-7,45.0 | 175.675 | 174.057 | 0.864 | TC was replaced to the highest value. | 1 | 0.864 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:03:40 | ||
333-C0011D-19H-7,115.0 | 176.375 | 174.609 | 0.947 | TC was replaced to the highest value. | 1 | 0.947 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T01:04:02 | ||
333-C0011D-20H-1,33.0 | 175.330 | 175.309 | 0.957 | 1 | 0.957 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:23:31 | |||
333-C0011D-20H-2,30.0 | 175.705 | 175.659 | 0.992 | TC was replaced to the highest value. | 1 | 0.992 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:24:00 | ||
333-C0011D-20H-2,100.0 | 176.405 | 176.314 | 0.987 | TC was replaced to the highest value. | 1 | 0.987 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:24:19 | ||
333-C0011D-20H-3,30.0 | 177.125 | 176.988 | 1.023 | TC was replaced to the highest value. | 1 | 1.023 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:24:41 | ||
333-C0011D-20H-3,70.0 | 177.525 | 177.362 | 1.039 | TC was replaced to the highest value. | 1 | 1.039 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:25:02 | ||
333-C0011D-20H-5,30.0 | 178.525 | 178.297 | 1.015 | TC was replaced to the highest value. | 1 | 1.015 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:25:25 | ||
333-C0011D-20H-5,100.0 | 179.225 | 178.952 | 0.993 | TC was replaced to the highest value. | 1 | 0.993 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:25:49 | ||
333-C0011D-20H-6,30.0 | 179.955 | 179.635 | 0.989 | TC was replaced to the highest value. | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:26:11 | ||
333-C0011D-20H-6,75.0 | 180.405 | 180.056 | 1.024 | TC was replaced to the highest value. | 1 | 1.024 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:26:42 | ||
333-C0011D-21H-1,30.0 | 180.800 | 180.716 | 1.065 | TC was replaced to the highest value. | 1 | 1.065 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:27:47 | ||
333-C0011D-21H-1,100.0 | 181.500 | 181.221 | 1.059 | TC was replaced to the highest value. | 1 | 1.059 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:28:07 | ||
333-C0011D-21H-2,30.0 | 182.200 | 181.725 | 0.902 | TC was replaced to the highest value. | 1 | 0.902 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:28:35 | ||
333-C0011D-21H-2,80.0 | 182.700 | 182.086 | 1.055 | TC was replaced to the highest value. | 1 | 1.055 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:28:58 | ||
333-C0011D-21H-3,16.0 | 183.470 | 182.641 | 1.085 | TC was replaced to the highest value. | 1 | 1.085 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:29:22 | ||
333-C0011D-21H-5,23.0 | 183.990 | 183.015 | 1.023 | TC was replaced to the highest value. | 1 | 1.023 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:29:52 | ||
333-C0011D-21H-5,101.0 | 184.770 | 183.577 | 1.037 | TC was replaced to the highest value. | 1 | 1.037 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:30:22 | ||
333-C0011D-21H-6,21.0 | 185.170 | 183.866 | 0.922 | 1 | 0.922 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:18:03 | |||
333-C0011D-21H-6,54.0 | 185.500 | 184.104 | 0.941 | 1 | 0.941 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:31:35 | |||
333-C0011D-22H-1,30.0 | 184.800 | 184.574 | 0.982 | TC was replaced to the highest value. | 1 | 0.982 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:32:37 | ||
333-C0011D-22H-1,100.0 | 185.500 | 184.748 | 1.018 | TC was replaced to the highest value. | 1 | 1.018 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:18:37 | ||
333-C0011D-22H-2,21.0 | 186.110 | 184.900 | 0.933 | TC was replaced to the highest value. | 1 | 0.933 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:33:01 | ||
333-C0011D-22H-2,71.0 | 186.610 | 185.024 | 1.033 | TC was replaced to the highest value. | 1 | 1.033 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:19:04 | ||
333-C0011D-22H-3,30.0 | 187.055 | 185.135 | 1.032 | TC was replaced to the highest value. | 1 | 1.032 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:33:23 | ||
333-C0011D-22H-3,90.0 | 187.655 | 185.283 | 1.031 | TC was replaced to the highest value. | 1 | 1.031 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:19:48 | ||
333-C0011D-22H-4,30.0 | 188.110 | 185.396 | 0.984 | TC was replaced to the highest value. | 1 | 0.984 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:33:44 | ||
333-C0011D-22H-4,90.0 | 188.710 | 185.546 | 1.032 | 1 | 1.032 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:20:14 | |||
333-C0011D-22H-5,30.0 | 189.175 | 185.661 | 1.004 | TC was replaced to the highest value. | 1 | 1.004 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:34:06 | ||
333-C0011D-22H-5,100.0 | 189.875 | 185.835 | 1.012 | 1 | 1.012 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:20:38 | |||
333-C0011D-23T-1,44.0 | 186.440 | 186.440 | 0.938 | TC was replaced to the highest value. | 1 | 0.938 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:34:31 | ||
333-C0011D-23T-1,106.0 | 187.060 | 187.060 | 0.974 | TC was replaced to the highest value. | 1 | 0.974 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:21:01 | ||
333-C0011D-23T-2,41.0 | 187.815 | 187.815 | 0.987 | TC was replaced to the highest value. | 1 | 0.987 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:35:02 | ||
333-C0011D-23T-2,107.0 | 188.475 | 188.475 | 0.974 | TC was replaced to the highest value. | 1 | 0.974 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:21:26 | ||
333-C0011D-23T-3,30.0 | 189.115 | 189.115 | 1.004 | TC was replaced to the highest value. | 1 | 1.004 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:37:12 | ||
333-C0011D-23T-3,100.0 | 189.815 | 189.815 | 1.021 | TC was replaced to the highest value. | 1 | 1.021 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:21:54 | ||
333-C0011D-25T-1,50.0 | 200.500 | 200.500 | 1.065 | 1 | 1.065 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:37:37 | |||
333-C0011D-25T-3,30.0 | 201.465 | 201.465 | 1.017 | TC was replaced to the highest value. | 1 | 1.017 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T01:41:16 | ||
333-C0011D-25T-3,100.0 | 202.165 | 202.165 | 1.008 | 1 | 1.008 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-31T00:44:13 | |||
333-C0011D-25T-4,8.0 | 202.650 | 202.650 | 0.955 | TC was replaced to the highest value. | 1 | 0.955 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T01:42:27 | ||
333-C0011D-26X-1,115.0 | 206.150 | 205.692 | 0.951 | 1 | 0.951 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-31T00:44:38 | |||
333-C0011D-26X-2,30.0 | 206.710 | 206.029 | 0.878 | TC was replaced to the highest value. | 1 | 0.878 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:38:50 | ||
333-C0011D-26X-2,100.0 | 207.410 | 206.450 | 0.905 | 1 | 0.905 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-31T00:45:04 | |||
333-C0011D-26X-4,28.0 | 208.425 | 207.061 | 1.016 | 1 | 1.016 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:39:14 | |||
333-C0011D-26X-4,100.0 | 209.145 | 207.494 | 1.046 | TC was replaced to the highest value. | 1 | 1.046 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-31T00:48:23 | ||
333-C0011D-26X-5,30.0 | 209.530 | 207.726 | 0.991 | TC was replaced to the highest value. | 1 | 0.991 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:39:35 | ||
333-C0011D-26X-5,100.0 | 210.230 | 208.147 | 1.026 | 1 | 1.026 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-31T00:48:41 | |||
333-C0011D-26X-6,45.0 | 211.085 | 208.661 | 0.989 | TC was replaced to the highest value. | 1 | 0.989 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:39:57 | ||
333-C0011D-26X-6,103.0 | 211.665 | 209.010 | 1.002 | TC was replaced to the highest value. | 1 | 1.002 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:40:25 | ||
333-C0011D-26X-7,28.0 | 212.320 | 209.404 | 1.025 | TC was replaced to the highest value. | 1 | 1.025 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:40:54 | ||
333-C0011D-26X-7,90.0 | 212.940 | 209.777 | 1.020 | TC was replaced to the highest value. | 1 | 1.020 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-31T00:49:30 | ||
333-C0011D-27X-1,30.0 | 210.300 | 210.225 | 0.979 | TC was replaced to the highest value. | 1 | 0.979 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:41:18 | ||
333-C0011D-27X-1,106.0 | 211.060 | 210.796 | 0.976 | TC was replaced to the highest value. | 1 | 0.976 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:42:25 | ||
333-C0011D-27X-2,30.0 | 211.705 | 211.280 | 1.011 | TC was replaced to the highest value. | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:42:50 | ||
333-C0011D-27X-2,112.0 | 212.525 | 211.896 | 0.893 | TC was replaced to the highest value. | 1 | 0.893 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:44:37 | ||
333-C0011D-27X-4,20.0 | 213.370 | 212.530 | 0.900 | 1 | 0.900 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:45:02 | |||
333-C0011D-27X-4,83.0 | 214.000 | 213.003 | 0.964 | TC was replaced to the highest value. | 1 | 0.964 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:45:42 | ||
333-C0011D-27X-5,34.0 | 214.610 | 213.461 | 0.958 | TC was replaced to the highest value. | 1 | 0.958 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:46:07 | ||
333-C0011D-27X-5,102.0 | 215.290 | 213.971 | 1.023 | TC was replaced to the highest value. | 1 | 1.023 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:46:27 | ||
333-C0011D-27X-6,16.0 | 215.835 | 214.381 | 1.018 | 1 | 1.018 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:46:48 | |||
333-C0011D-27X-CC,23.0 | 216.590 | 214.947 | 0.898 | TC was replaced to the highest value. | 1 | 0.898 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:47:14 | ||
333-C0011D-28X-1,30.0 | 215.300 | 215.278 | 0.942 | TC was replaced to the highest value. | 1 | 0.942 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:47:38 | ||
333-C0011D-28X-2,30.0 | 216.715 | 216.588 | 0.963 | TC was replaced to the highest value. | 1 | 0.963 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:48:02 | ||
333-C0011D-28X-2,87.0 | 217.285 | 217.116 | 0.986 | 1 | 0.986 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:48:24 | |||
333-C0011D-28X-3,30.0 | 218.120 | 217.889 | 0.942 | TC was replaced to the highest value. | 1 | 0.942 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:48:51 | ||
333-C0011D-28X-3,100.0 | 218.820 | 218.537 | 0.953 | TC was replaced to the highest value. | 1 | 0.953 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:49:18 | ||
333-C0011D-28X-4,27.0 | 219.500 | 219.167 | 0.899 | TC was replaced to the highest value. | 1 | 0.899 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:49:40 | ||
333-C0011D-28X-4,73.0 | 219.960 | 219.593 | 0.890 | TC was replaced to the highest value. | 1 | 0.890 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:50:03 | ||
333-C0011D-29X-1,24.0 | 220.240 | 220.204 | 0.941 | 1 | 0.941 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:50:26 | |||
333-C0011D-29X-1,100.0 | 221.000 | 220.852 | 0.924 | 1 | 0.924 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:50:48 | |||
333-C0011D-29X-2,30.0 | 221.705 | 221.452 | 0.937 | TC was replaced to the highest value. | 1 | 0.937 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:53:15 | ||
333-C0011D-29X-2,100.0 | 222.405 | 222.049 | 0.985 | TC was replaced to the highest value. | 1 | 0.985 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:51:14 | ||
333-C0011D-29X-3,30.0 | 223.115 | 222.653 | 0.976 | TC was replaced to the highest value. | 1 | 0.976 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:53:43 | ||
333-C0011D-29X-3,60.0 | 223.415 | 222.909 | 1.043 | TC was replaced to the highest value. | 1 | 1.043 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:54:06 | ||
333-C0011D-29X-5,30.0 | 224.535 | 223.863 | 0.939 | TC was replaced to the highest value. | 1 | 0.939 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:54:29 | ||
333-C0011D-29X-5,100.0 | 225.235 | 224.459 | 1.011 | TC was replaced to the highest value. | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-23T23:54:47 | ||
333-C0011D-30X-1,62.0 | 225.620 | 225.620 | 0.913 | TC was replaced to the highest value. | 1 | 0.913 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:26:20 | ||
333-C0011D-30X-1,100.0 | 226.000 | 226.000 | 0.898 | 1 | 0.898 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:26:56 | |||
333-C0011D-30X-2,46.0 | 226.860 | 226.860 | 0.804 | TC was replaced to the highest value. | 1 | 0.804 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:27:20 | ||
333-C0011D-30X-2,108.0 | 227.480 | 227.480 | 0.824 | 1 | 0.824 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:27:43 | |||
333-C0011D-30X-3,55.0 | 228.175 | 228.175 | 0.970 | 1 | 0.970 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:28:04 | |||
333-C0011D-30X-3,113.0 | 228.755 | 228.755 | 0.794 | 1 | 0.794 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:28:30 | |||
333-C0011D-31X-1,42.0 | 234.920 | 234.920 | 0.947 | 1 | 0.947 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:28:56 | |||
333-C0011D-31X-1,101.0 | 235.510 | 235.510 | 0.949 | TC was replaced to the highest value. | 1 | 0.949 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:29:20 | ||
333-C0011D-31X-2,24.0 | 236.125 | 236.125 | 0.900 | TC was replaced to the highest value. | 1 | 0.900 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:29:44 | ||
333-C0011D-31X-2,100.0 | 236.885 | 236.885 | 0.933 | 1 | 0.933 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:30:02 | |||
333-C0011D-31X-3,25.0 | 237.545 | 237.545 | 0.975 | 1 | 0.975 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:30:31 | |||
333-C0011D-31X-3,64.0 | 237.935 | 237.935 | 1.099 | 1 | 1.099 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:30:52 | |||
333-C0011D-31X-5,26.0 | 238.710 | 238.710 | 0.898 | TC was replaced to the highest value. | 1 | 0.898 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:31:15 | ||
333-C0011D-31X-5,110.0 | 239.550 | 239.550 | 0.961 | TC was replaced to the highest value. | 1 | 0.961 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:31:46 | ||
333-C0011D-31X-6,22.0 | 240.080 | 240.080 | 0.917 | TC was replaced to the highest value. | 1 | 0.917 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:32:09 | ||
333-C0011D-31X-6,57.0 | 240.430 | 240.430 | 0.988 | 1 | 0.988 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:32:30 | |||
333-C0011D-32X-1,64.0 | 242.140 | 242.074 | 0.842 | TC was replaced to the highest value. | 1 | 0.842 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:32:58 | ||
333-C0011D-32X-1,120.0 | 242.700 | 242.575 | 0.966 | 1 | 0.966 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:33:21 | |||
333-C0011D-32X-2,30.0 | 243.205 | 243.028 | 0.951 | 1 | 0.951 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:33:44 | |||
333-C0011D-32X-2,100.0 | 243.905 | 243.655 | 0.936 | TC was replaced to the highest value. | 1 | 0.936 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:37:11 | ||
333-C0011D-32X-3,19.0 | 244.505 | 244.193 | 0.843 | TC was replaced to the highest value. | 1 | 0.843 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:37:42 | ||
333-C0011D-32X-5,30.0 | 245.210 | 244.824 | 0.976 | TC was replaced to the highest value. | 1 | 0.976 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:38:07 | ||
333-C0011D-32X-5,100.0 | 245.910 | 245.452 | 0.872 | TC was replaced to the highest value. | 1 | 0.872 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:38:29 | ||
333-C0011D-33X-1,30.0 | 246.800 | 246.778 | 0.952 | 1 | 0.952 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:38:55 | |||
333-C0011D-33X-1,100.0 | 247.500 | 247.428 | 0.885 | TC was replaced to the highest value. | 1 | 0.885 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:39:16 | ||
333-C0011D-33X-2,30.0 | 248.185 | 248.063 | 0.978 | T | 1 | 0.978 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:39:45 | ||
333-C0011D-33X-2,100.0 | 248.885 | 248.712 | 0.907 | 1 | 0.907 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:40:05 | |||
333-C0011D-33X-4,25.0 | 249.630 | 249.404 | 0.946 | TC was replaced to the highest value. | 1 | 0.946 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:40:28 | ||
333-C0011D-33X-4,94.0 | 250.320 | 250.044 | 0.888 | TC was replaced to the highest value. | 1 | 0.888 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:40:50 | ||
333-C0011D-33X-5,20.0 | 250.980 | 250.656 | 1.013 | TC was replaced to the highest value. | 1 | 1.013 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:41:13 | ||
333-C0011D-33X-5,48.0 | 251.260 | 250.916 | 1.000 | TC was replaced to the highest value. | 1 | 1.000 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:41:35 | ||
333-C0011D-34X-1,50.0 | 252.000 | 251.845 | 1.003 | TC was replaced to the highest value. | 1 | 1.003 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:41:55 | ||
333-C0011D-34X-1,102.0 | 252.520 | 252.204 | 1.002 | 1 | 1.002 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:42:16 | |||
333-C0011D-34X-2,30.0 | 253.205 | 252.676 | 1.016 | TC was replaced to the highest value. | 1 | 1.016 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:42:39 | ||
333-C0011D-34X-2,100.0 | 253.905 | 253.159 | 1.089 | 1 | 1.089 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:43:47 | |||
333-C0011D-34X-3,30.0 | 254.615 | 253.648 | 0.950 | TC was replaced to the highest value. | 1 | 0.950 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:43:02 | ||
333-C0011D-34X-3,98.0 | 255.295 | 254.117 | 1.081 | 1 | 1.081 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:45:03 | |||
333-C0011D-34X-5,40.0 | 256.525 | 254.965 | 1.082 | TC was replaced to the highest value. | 1 | 1.082 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:45:26 | ||
333-C0011D-34X-5,110.0 | 257.225 | 255.448 | 1.115 | 1 | 1.115 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:45:49 | |||
333-C0011D-34X-6,24.0 | 257.775 | 255.828 | 1.160 | TC was replaced to the highest value. | 1 | 1.160 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:46:13 | ||
333-C0011D-34X-6,61.0 | 258.145 | 256.083 | 1.143 | 1 | 1.143 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:46:38 | |||
333-C0011D-34X-CC,32.0 | 258.660 | 256.438 | 1.190 | TC was replaced to the highest value. | 1 | 1.190 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:46:59 | ||
333-C0011D-35X-1,62.0 | 257.120 | 257.120 | 0.970 | 1 | 0.970 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-24T00:47:34 | |||
333-C0011D-36X-1,30.0 | 266.300 | 266.283 | 1.143 | TC was replaced to the highest value. | 1 | 1.143 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:22:38 | ||
333-C0011D-36X-1,100.0 | 267.000 | 266.941 | 1.176 | 1 | 1.176 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:23:02 | |||
333-C0011D-36X-2,30.0 | 267.705 | 267.605 | 1.152 | TC was replaced to the highest value. | 1 | 1.152 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:23:28 | ||
333-C0011D-36X-2,125.0 | 268.655 | 268.500 | 1.164 | TC was replaced to the highest value. | 1 | 1.164 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:23:58 | ||
333-C0011D-36X-3,30.0 | 269.125 | 268.942 | 1.212 | TC was replaced to the highest value. | 1 | 1.212 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:24:22 | ||
333-C0011D-36X-3,100.0 | 269.825 | 269.601 | 1.206 | TC was replaced to the highest value. | 1 | 1.206 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:24:46 | ||
333-C0011D-36X-4,25.0 | 270.480 | 270.218 | 1.215 | 1 | 1.215 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:25:14 | |||
333-C0011D-36X-4,79.0 | 271.020 | 270.727 | 1.123 | 1 | 1.123 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:25:38 | |||
333-C0011D-36X-6,30.0 | 271.940 | 271.593 | 1.139 | TC was replaced to the highest value. | 1 | 1.139 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:26:07 | ||
333-C0011D-36X-6,100.0 | 272.640 | 272.252 | 1.196 | 1 | 1.196 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:26:28 | |||
333-C0011D-36X-7,30.0 | 273.350 | 272.920 | 1.198 | TC was replaced to the highest value. | 1 | 1.198 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:26:51 | ||
333-C0011D-36X-7,100.0 | 274.050 | 273.579 | 1.168 | TC was replaced to the highest value. | 1 | 1.168 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:27:18 | ||
333-C0011D-36X-8,35.0 | 274.810 | 274.295 | 1.189 | TC was replaced to the highest value. | 1 | 1.189 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:27:40 | ||
333-C0011D-36X-8,98.0 | 275.440 | 274.888 | 1.119 | TC was replaced to the highest value. | 1 | 1.119 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:28:07 | ||
333-C0011D-36X-CC,30.0 | 275.870 | 275.293 | 1.095 | TC was replaced to the highest value. | 1 | 1.095 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:28:27 | ||
333-C0011D-37X-1,30.0 | 275.800 | 275.775 | 1.086 | 1 | 1.086 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:28:58 | |||
333-C0011D-37X-1,72.0 | 276.220 | 276.160 | 1.118 | 1 | 1.118 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:29:19 | |||
333-C0011D-37X-2,25.0 | 277.130 | 276.993 | 1.012 | 1 | 1.012 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:12:17 | |||
333-C0011D-37X-2,110.0 | 277.980 | 277.772 | 1.151 | TC was replaced to the highest value. | 1 | 1.151 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:29:59 | ||
333-C0011D-37X-3,28.0 | 278.570 | 278.313 | 1.185 | TC was replaced to the highest value. | 1 | 1.185 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:16:03 | ||
333-C0011D-37X-3,110.0 | 279.390 | 279.064 | 1.177 | TC was replaced to the highest value. | 1 | 1.177 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:30:32 | ||
333-C0011D-37X-5,30.0 | 280.345 | 279.939 | 1.203 | TC was replaced to the highest value. | 1 | 1.203 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:18:39 | ||
333-C0011D-37X-5,90.0 | 280.945 | 280.489 | 1.225 | 1 | 1.225 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:31:04 | |||
333-C0011D-37X-6,30.0 | 281.425 | 280.929 | 1.190 | 1 | 1.190 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:19:03 | |||
333-C0011D-37X-6,92.0 | 282.045 | 281.497 | 1.120 | TC was replaced to the highest value. | 1 | 1.120 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:31:36 | ||
333-C0011D-37X-7,30.0 | 282.430 | 281.849 | 1.150 | TC was replaced to the highest value. | 1 | 1.150 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:19:36 | ||
333-C0011D-37X-7,55.0 | 282.680 | 282.078 | 1.174 | 1 | 1.174 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:32:38 | |||
333-C0011D-38X-1,30.0 | 282.800 | 282.800 | 1.024 | TC was replaced to the highest value. | 1 | 1.024 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:20:04 | ||
333-C0011D-38X-1,100.0 | 283.500 | 283.500 | 1.173 | TC was replaced to the highest value. | 1 | 1.173 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:33:10 | ||
333-C0011D-38X-2,30.0 | 284.210 | 284.210 | 1.052 | TC was replaced to the highest value. | 1 | 1.052 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:20:29 | ||
333-C0011D-38X-2,125.0 | 285.160 | 285.160 | 1.102 | TC was replaced to the highest value. | 1 | 1.102 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:33:34 | ||
333-C0011D-38X-4,15.0 | 285.840 | 285.840 | 1.133 | TC was replaced to the highest value. | 1 | 1.133 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:20:53 | ||
333-C0011D-38X-4,45.0 | 286.140 | 286.140 | 1.106 | TC was replaced to the highest value. | 1 | 1.106 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:34:12 | ||
333-C0011D-38X-6,30.0 | 287.975 | 287.975 | 1.151 | TC was replaced to the highest value. | 1 | 1.151 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:21:18 | ||
333-C0011D-38X-6,100.0 | 288.675 | 288.675 | 1.174 | 1 | 1.174 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:34:34 | |||
333-C0011D-38X-7,19.0 | 289.345 | 289.345 | 1.131 | TC was replaced to the highest value. | 1 | 1.131 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:21:41 | ||
333-C0011D-38X-CC,15.0 | 289.845 | 289.845 | 1.141 | 1 | 1.141 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:36:42 | |||
333-C0011D-39X-1,25.0 | 292.250 | 292.240 | 1.230 | TC was replaced to the highest value. | 1 | 1.230 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:37:30 | ||
333-C0011D-39X-1,77.0 | 292.770 | 292.738 | 1.152 | TC was replaced to the highest value. | 1 | 1.152 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:37:52 | ||
333-C0011D-39X-2,35.0 | 293.750 | 293.678 | 1.240 | TC was replaced to the highest value. | 1 | 1.240 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:38:16 | ||
333-C0011D-39X-2,105.0 | 294.450 | 294.349 | 1.192 | TC was replaced to the highest value. | 1 | 1.192 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:41:18 | ||
333-C0011D-39X-3,55.0 | 295.360 | 295.221 | 1.187 | TC was replaced to the highest value. | 1 | 1.187 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:42:10 | ||
333-C0011D-39X-3,120.0 | 296.010 | 295.844 | 1.156 | TC was replaced to the highest value. | 1 | 1.156 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:41:41 | ||
333-C0011D-39X-4,35.0 | 296.560 | 296.371 | 1.262 | TC was replaced to the highest value. | 1 | 1.262 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:43:11 | ||
333-C0011D-39X-4,90.0 | 297.110 | 296.899 | 1.228 | 1 | 1.228 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:43:34 | |||
333-C0011D-39X-6,30.0 | 297.930 | 297.685 | 1.210 | TC was replaced to the highest value. | 1 | 1.210 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:43:56 | ||
333-C0011D-39X-6,100.0 | 298.630 | 298.356 | 1.182 | 1 | 1.182 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:44:19 | |||
333-C0011D-39X-7,30.0 | 299.350 | 299.046 | 1.165 | TC was replaced to the highest value. | 1 | 1.165 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:44:51 | ||
333-C0011D-39X-7,110.0 | 300.150 | 299.813 | 1.232 | 1 | 1.232 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:45:11 | |||
333-C0011D-39X-8,53.0 | 300.995 | 300.623 | 1.125 | TC was replaced to the highest value. | 1 | 1.125 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:45:37 | ||
333-C0011D-39X-8,96.0 | 301.425 | 301.035 | 1.234 | 1 | 1.234 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:46:00 | |||
333-C0011D-39X-CC,24.0 | 301.770 | 301.366 | 1.133 | TC was replaced to the highest value. | 1 | 1.133 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:46:42 | ||
333-C0011D-40X-1,8.0 | 301.580 | 301.576 | 1.201 | TC was replaced to the highest value. | 1 | 1.201 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:47:07 | ||
333-C0011D-40X-1,108.0 | 302.580 | 302.521 | 1.177 | 1 | 1.177 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:47:29 | |||
333-C0011D-40X-2,35.0 | 303.255 | 303.159 | 1.202 | 1 | 1.202 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:47:52 | |||
333-C0011D-40X-2,100.0 | 303.905 | 303.773 | 1.192 | 1 | 1.192 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:48:12 | |||
333-C0011D-40X-3,10.0 | 304.420 | 304.260 | 1.230 | TC was replaced to the highest value. | 1 | 1.230 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:49:30 | ||
333-C0011D-40X-3,132.0 | 305.640 | 305.413 | 1.081 | 1 | 1.081 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:49:55 | |||
333-C0011D-40X-4,30.0 | 306.030 | 305.782 | 1.241 | TC was replaced to the highest value. | 1 | 1.241 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:50:18 | ||
333-C0011D-40X-6,30.0 | 307.255 | 306.940 | 1.242 | 1 | 1.242 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:51:52 | |||
333-C0011D-40X-6,101.0 | 307.965 | 307.611 | 1.240 | 1 | 1.240 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:52:16 | |||
333-C0011D-40X-7,30.0 | 308.665 | 308.273 | 1.148 | TC was replaced to the highest value. | 1 | 1.148 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:52:38 | ||
333-C0011D-40X-7,100.0 | 309.365 | 308.935 | 1.280 | 1 | 1.280 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:52:58 | |||
333-C0011D-40X-8,30.0 | 310.075 | 309.606 | 1.259 | TC was replaced to the highest value. | 1 | 1.259 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:53:20 | ||
333-C0011D-40X-8,100.0 | 310.775 | 310.267 | 1.285 | TC was replaced to the highest value. | 1 | 1.285 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:53:41 | ||
333-C0011D-40X-CC,23.0 | 311.270 | 310.735 | 1.209 | TC was replaced to the highest value. | 1 | 1.209 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:54:07 | ||
333-C0011D-41X-1,32.0 | 311.320 | 311.320 | 1.313 | HLQ | 1 | 1.313 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:23:18 | ||
333-C0011D-41X-1,37.0 | 311.370 | 311.370 | 1.203 | 1 | 1.203 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:54:32 | |||
333-C0011D-41X-1,100.0 | 312.000 | 312.000 | 1.218 | 1 | 1.218 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:54:52 | |||
333-C0011D-41X-2,12.0 | 312.470 | 312.470 | 1.305 | HLQ | 1 | 1.305 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:23:41 | ||
333-C0011D-41X-2,30.0 | 312.650 | 312.650 | 1.188 | TC was replaced to the highest value. | 1 | 1.188 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:55:14 | ||
333-C0011D-41X-2,100.0 | 313.350 | 313.350 | 1.231 | 1 | 1.231 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:55:33 | |||
333-C0011D-41X-3,17.0 | 313.930 | 313.930 | 1.220 | TC was replaced to the highest value. | 1 | 1.220 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:55:57 | ||
333-C0011D-41X-3,81.0 | 314.570 | 314.570 | 1.278 | HLQ | 1 | 1.278 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:24:06 | ||
333-C0011D-41X-3,100.0 | 314.760 | 314.760 | 1.150 | 1 | 1.150 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:56:20 | |||
333-C0011D-41X-4,26.0 | 315.435 | 315.435 | 1.177 | 1 | 1.177 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:56:44 | |||
333-C0011D-41X-4,64.0 | 315.815 | 315.815 | 1.094 | 1 | 1.094 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:57:15 | |||
333-C0011D-41X-4,76.0 | 315.935 | 315.935 | 1.260 | HLQ | 1 | 1.260 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:24:30 | ||
333-C0011D-41X-6,30.0 | 317.075 | 317.075 | 1.231 | TC was replaced to the highest value. | 1 | 1.231 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:57:42 | ||
333-C0011D-41X-6,57.0 | 317.345 | 317.345 | 1.234 | HLQ | 1 | 1.234 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:24:53 | ||
333-C0011D-41X-6,100.0 | 317.775 | 317.775 | 1.143 | 1 | 1.143 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:58:01 | |||
333-C0011D-41X-7,30.0 | 318.485 | 318.485 | 1.197 | 1 | 1.197 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:58:23 | |||
333-C0011D-41X-7,85.0 | 319.035 | 319.035 | 0.969 | HLQ | 1 | 0.969 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:25:16 | ||
333-C0011D-41X-7,100.0 | 319.185 | 319.185 | 1.202 | 1 | 1.202 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:58:42 | |||
333-C0011D-41X-CC,25.0 | 319.845 | 319.845 | 1.222 | 1 | 1.222 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:59:04 | |||
333-C0011D-42X-1,30.0 | 320.300 | 320.286 | 1.154 | TC was replaced to the highest value. | 1 | 1.154 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:59:26 | ||
333-C0011D-42X-1,101.0 | 321.010 | 320.962 | 1.161 | TC was replaced to the highest value. | 1 | 1.161 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T00:59:49 | ||
333-C0011D-42X-2,30.0 | 321.705 | 321.625 | 1.199 | TC was replaced to the highest value. | 1 | 1.199 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:00:13 | ||
333-C0011D-42X-2,73.0 | 322.135 | 322.034 | 1.160 | HLQ | 2 | 1.162 | 1.158 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:27:56 | |
333-C0011D-42X-2,101.0 | 322.415 | 322.301 | 1.144 | 1 | 1.144 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:00:43 | |||
333-C0011D-42X-3,20.0 | 323.005 | 322.863 | 1.188 | HLQ | 3 | 1.203 | 1.145 | 1.217 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2011-01-04T13:22:38 |
333-C0011D-42X-3,30.0 | 323.105 | 322.959 | 1.149 | TC was replaced to the highest value. | 1 | 1.149 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:01:07 | ||
333-C0011D-42X-3,101.0 | 323.815 | 323.635 | 1.198 | 1 | 1.198 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:01:28 | |||
333-C0011D-42X-5,30.0 | 324.920 | 324.688 | 1.158 | TC was replaced to the highest value. | 1 | 1.158 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:01:54 | ||
333-C0011D-42X-5,73.0 | 325.350 | 325.098 | 1.245 | HLQ | 3 | 1.238 | 1.258 | 1.239 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2011-01-04T13:23:06 |
333-C0011D-42X-5,100.0 | 325.620 | 325.355 | 1.207 | 1 | 1.207 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:02:13 | |||
333-C0011D-42X-6,30.0 | 326.330 | 326.032 | 1.098 | TC was replaced to the highest value. | 1 | 1.098 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:02:35 | ||
333-C0011D-42X-6,100.0 | 327.030 | 326.699 | 1.202 | 1 | 1.202 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:02:57 | |||
333-C0011D-42X-7,30.0 | 327.735 | 327.370 | 1.147 | TC was replaced to the highest value. | 1 | 1.147 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:03:23 | ||
333-C0011D-42X-7,100.0 | 328.435 | 328.037 | 1.204 | 1 | 1.204 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:03:44 | |||
333-C0011D-42X-7,113.0 | 328.565 | 328.161 | 1.272 | HLQ | 3 | 1.231 | 1.304 | 1.282 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2011-01-04T13:23:39 |
333-C0011D-42X-8,22.0 | 329.060 | 328.633 | 1.271 | TC was replaced to the highest value. | 1 | 1.271 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:04:06 | ||
333-C0011D-42X-8,55.0 | 329.390 | 328.947 | 1.238 | TC was replaced to the highest value. | 1 | 1.238 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:04:59 | ||
333-C0011D-42X-CC,21.0 | 329.700 | 329.243 | 1.073 | TC was replaced to the highest value. | 1 | 1.073 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:06:07 | ||
333-C0011D-43X-1,24.0 | 329.740 | 329.697 | 1.212 | TC was replaced to the highest value. | 1 | 1.212 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:06:33 | ||
333-C0011D-43X-1,100.0 | 330.500 | 330.321 | 1.048 | 1 | 1.048 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:08:53 | |||
333-C0011D-43X-2,30.0 | 331.180 | 330.879 | 1.126 | TC was replaced to the highest value. | 1 | 1.126 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:09:19 | ||
333-C0011D-43X-2,100.0 | 331.880 | 331.454 | 1.187 | 1 | 1.187 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:09:40 | |||
333-C0011D-43X-4,30.0 | 332.970 | 332.349 | 1.184 | TC was replaced to the highest value. | 1 | 1.184 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:10:01 | ||
333-C0011D-43X-4,84.0 | 333.510 | 332.792 | 1.212 | HLQ | 3 | 1.197 | 1.197 | 1.243 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:29:27 |
333-C0011D-43X-4,100.0 | 333.670 | 332.924 | 1.175 | TC was replaced to the highest value. | 1 | 1.175 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:10:19 | ||
333-C0011D-43X-5,30.0 | 334.375 | 333.503 | 1.173 | TC was replaced to the highest value. | 1 | 1.173 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:10:44 | ||
333-C0011D-43X-5,90.0 | 334.975 | 333.995 | 1.107 | 1 | 1.107 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:11:04 | |||
333-C0011D-43X-CC,12.0 | 335.300 | 334.262 | 0.911 | HLQ | 1 | 0.911 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:29:54 | ||
333-C0011D-43X-CC,24.0 | 335.420 | 334.360 | 1.145 | 1 | 1.145 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:11:26 | |||
333-C0011D-44X-1,43.0 | 334.930 | 334.861 | 1.081 | 1 | 1.081 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:11:49 | |||
333-C0011D-44X-1,90.0 | 335.400 | 335.256 | 1.110 | 1 | 1.110 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:12:10 | |||
333-C0011D-44X-2,30.0 | 336.210 | 335.937 | 1.150 | TC was replaced to the highest value. | 1 | 1.150 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:12:34 | ||
333-C0011D-44X-2,100.0 | 336.910 | 336.525 | 1.160 | 1 | 1.160 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:12:57 | |||
333-C0011D-44X-2,124.0 | 337.150 | 336.727 | 1.174 | HLQ | 1 | 1.174 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2011-01-04T13:24:10 | ||
333-C0011D-44X-3,21.0 | 337.525 | 337.042 | 1.022 | TC was replaced to the highest value. | 1 | 1.022 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:13:21 | ||
333-C0011D-44X-5,36.0 | 338.480 | 337.845 | 1.154 | 1 | 1.154 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:13:44 | |||
333-C0011D-44X-6,38.0 | 339.130 | 338.391 | 1.067 | TC was replaced to the highest value. | 1 | 1.067 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:14:05 | ||
333-C0011D-44X-6,100.0 | 339.750 | 338.912 | 1.018 | TC was replaced to the highest value. | 1 | 1.018 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:14:23 | ||
333-C0011D-44X-CC,28.0 | 340.380 | 339.441 | 1.026 | 1 | 1.026 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:14:44 | |||
333-C0011D-45X-1,18.0 | 339.680 | 339.665 | 0.999 | HLQ | 1 | 0.999 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:30:45 | ||
333-C0011D-45X-1,30.0 | 339.800 | 339.775 | 1.040 | 1 | 1.040 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:15:06 | |||
333-C0011D-45X-1,100.0 | 340.500 | 340.417 | 1.011 | TC was replaced to the highest value. | 1 | 1.011 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:15:26 | ||
333-C0011D-45X-2,30.0 | 341.205 | 341.064 | 1.124 | TC was replaced to the highest value. | 1 | 1.124 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:15:49 | ||
333-C0011D-45X-2,100.0 | 341.905 | 341.706 | 1.150 | 1 | 1.150 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:16:08 | |||
333-C0011D-45X-4,30.0 | 343.020 | 342.729 | 1.134 | TC was replaced to the highest value. | 1 | 1.134 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:16:30 | ||
333-C0011D-45X-4,89.0 | 343.610 | 343.271 | 1.179 | 1 | 1.179 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:16:53 | |||
333-C0011D-45X-5,18.0 | 343.915 | 343.551 | 1.099 | TC was replaced to the highest value. | 1 | 1.099 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:17:16 | ||
333-C0011D-45X-CC,33.0 | 344.845 | 344.404 | 1.104 | 1 | 1.104 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T01:17:45 | |||
333-C0011D-46X-1,30.0 | 344.800 | 344.777 | 1.191 | TC was replaced to the highest value. | 1 | 1.191 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:22:22 | ||
333-C0011D-46X-1,100.0 | 345.500 | 345.422 | 1.177 | 1 | 1.177 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:22:48 | |||
333-C0011D-46X-2,30.0 | 346.200 | 346.068 | 1.159 | 1.000 | 1.159 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:23:23 | |||
333-C0011D-46X-2,35.0 | 346.250 | 346.114 | 1.238 | HLQ | 1 | 1.238 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:31:15 | ||
333-C0011D-46X-2,80.0 | 346.700 | 346.530 | 1.155 | 1 | 1.155 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:23:54 | |||
333-C0011D-46X-4,30.0 | 347.620 | 347.378 | 1.133 | TC was replaced to the highest value. | 1 | 1.133 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:24:22 | ||
333-C0011D-46X-4,96.0 | 348.280 | 347.987 | 1.145 | HLQ | 1 | 1.145 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:31:40 | ||
333-C0011D-46X-4,100.0 | 348.320 | 348.024 | 1.106 | 1 | 1.106 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:24:45 | |||
333-C0011D-46X-5,22.0 | 348.950 | 348.605 | 0.937 | 1 | 0.937 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:25:26 | |||
333-C0011D-46X-5,26.0 | 348.990 | 348.642 | 1.190 | HLQ | 1 | 1.190 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:32:09 | ||
333-C0011D-46X-CC,38.0 | 349.560 | 349.168 | 1.165 | 1 | 1.165 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:25:51 | |||
333-C0011D-47X-1,30.0 | 349.800 | 349.727 | 1.134 | 1 | 1.134 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:26:21 | |||
333-C0011D-47X-1,102.0 | 350.520 | 350.273 | 0.712 | TC was replaced to the highest value. | 1 | 0.712 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:27:04 | ||
333-C0011D-47X-2,30.0 | 351.180 | 350.773 | 1.050 | 1 | 1.050 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:27:45 | |||
333-C0011D-47X-2,80.0 | 351.680 | 351.151 | 1.134 | TC was replaced to the highest value. | 1 | 1.134 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:28:08 | ||
333-C0011D-47X-3,32.0 | 352.210 | 351.553 | 1.097 | 1 | 1.097 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:28:30 | |||
333-C0011D-47X-4,30.0 | 352.590 | 351.841 | 1.036 | TC was replaced to the highest value. | 1 | 1.036 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:28:55 | ||
333-C0011D-47X-5,20.0 | 353.055 | 352.193 | 1.094 | TC was replaced to the highest value. | 1 | 1.094 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:30:18 | ||
333-C0011D-47X-6,30.0 | 353.555 | 352.572 | 1.038 | TC was replaced to the highest value. | 1 | 1.038 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:30:42 | ||
333-C0011D-47X-6,100.0 | 354.255 | 353.102 | 1.049 | 1 | 1.049 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:31:02 | |||
333-C0011D-47X-7,18.0 | 354.840 | 353.546 | 1.100 | 1 | 1.100 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:31:30 | |||
333-C0011D-47X-7,106.0 | 355.720 | 354.212 | 1.396 | 1 | 1.396 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:31:56 | |||
333-C0011D-48X-1,30.0 | 354.800 | 354.748 | 1.317 | 1 | 1.317 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:32:39 | |||
333-C0011D-48X-1,102.0 | 355.520 | 355.344 | 1.242 | 1 | 1.242 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:33:05 | |||
333-C0011D-48X-2,25.0 | 356.140 | 355.858 | 1.234 | 1 | 1.234 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:33:37 | |||
333-C0011D-48X-2,50.0 | 356.390 | 356.065 | 1.250 | 1 | 1.250 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:33:59 | |||
333-C0011D-48X-4,23.0 | 357.535 | 357.012 | 1.188 | HLQ | 1 | 1.188 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2010-12-29T07:32:39 | ||
333-C0011D-48X-4,28.0 | 357.585 | 357.054 | 1.111 | 1 | 1.111 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:34:24 | |||
333-C0011D-48X-5,35.0 | 358.065 | 357.451 | 1.322 | TC was replaced to the highest value. | 1 | 1.322 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:35:06 | ||
333-C0011D-48X-5,100.0 | 358.715 | 357.989 | 1.303 | 1 | 1.303 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:39:04 | |||
333-C0011D-48X-6,20.0 | 359.315 | 358.486 | 1.267 | 1 | 1.267 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:42:13 | |||
333-C0011D-49X-1,30.0 | 359.800 | 359.743 | 1.079 | 1 | 1.079 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:42:35 | |||
333-C0011D-49X-2,30.0 | 361.190 | 360.871 | 1.174 | TC was replaced to the highest value. | 1 | 1.174 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:43:00 | ||
333-C0011D-49X-2,96.0 | 361.850 | 361.406 | 1.200 | 1 | 1.200 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2011-01-04T07:16:12 | |||
333-C0011D-49X-2,100.0 | 361.890 | 361.439 | 0.998 | 1 | 0.998 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:43:23 | |||
333-C0011D-49X-4,17.0 | 362.955 | 362.303 | 0.921 | 1 | 0.921 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:43:48 | |||
333-C0011D-49X-5,105.0 | 365.245 | 364.160 | 0.990 | 1 | 0.990 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:44:42 | |||
333-C0011D-49X-5,125.0 | 365.445 | 364.323 | 1.033 | 1 | 1.033 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:45:32 | |||
333-C0011D-49X-6,20.0 | 365.805 | 364.615 | 1.049 | 1 | 1.049 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:45:59 | |||
333-C0011D-50X-1,20.0 | 365.200 | 365.174 | 0.943 | 1 | 0.943 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:46:23 | |||
333-C0011D-50X-1,100.0 | 366.000 | 365.873 | 1.085 | 1 | 1.085 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:46:48 | |||
333-C0011D-50X-2,103.0 | 367.430 | 367.120 | 0.616 | 1 | 0.616 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:47:29 | |||
333-C0011D-50X-3,28.0 | 368.090 | 367.696 | 0.903 | 1 | 0.903 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:49:20 | |||
333-C0011D-50X-4,30.0 | 369.525 | 368.948 | 1.290 | 1 | 1.290 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:48:04 | |||
333-C0011D-50X-4,97.0 | 370.195 | 369.533 | 1.306 | 1 | 1.306 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:48:37 | |||
333-C0011D-51X-1,30.0 | 370.300 | 370.300 | 1.409 | 1 | 1.409 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:49:49 | |||
333-C0011D-51X-1,100.0 | 371.000 | 371.000 | 1.323 | 1 | 1.323 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:50:14 | |||
333-C0011D-51X-2,30.0 | 371.675 | 371.675 | 1.274 | 1 | 1.274 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:50:56 | |||
333-C0011D-51X-2,72.0 | 372.095 | 372.095 | 1.214 | 1 | 1.214 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:51:21 | |||
333-C0011D-51X-3,22.0 | 373.010 | 373.010 | 1.179 | 1 | 1.179 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:51:48 | |||
333-C0011D-52X-1,30.0 | 375.300 | 375.300 | 1.280 | 1 | 1.280 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:52:17 | |||
333-C0011D-52X-1,113.0 | 376.130 | 376.130 | 1.108 | 1 | 1.108 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:52:39 | |||
333-C0011D-52X-2,4.0 | 376.435 | 376.435 | 1.176 | HLQ | 2 | 1.193 | 1.160 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 2011-01-04T13:25:01 | |
333-C0011D-52X-2,30.0 | 376.695 | 376.695 | 1.152 | TC was replaced to the highest value. | 1 | 1.152 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-27T07:52:03 | ||
333-C0011D-52X-2,101.0 | 377.405 | 377.405 | 1.231 | 1 | 1.231 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:53:28 | |||
333-C0011D-52X-3,25.0 | 378.060 | 378.060 | 1.203 | 1 | 1.203 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:54:02 | |||
333-C0011D-52X-5,32.0 | 379.270 | 379.270 | 1.250 | 1 | 1.250 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:54:27 | |||
333-C0011D-52X-CC,18.0 | 379.760 | 379.760 | 1.112 | 1 | 1.112 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2010-12-25T15:54:51 |