Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): Headspace-gas measurements from IODP Hole 333-C0018A [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.783489

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Other version:
IODP Hole 333-C0018A, snapshot taken on 2012-05-08, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/333/C0018A/
Coverage:
Latitude: 33.156992 * Longitude: 136.681480
Minimum DEPTH, sediment/rock: 0.750 m * Maximum DEPTH, sediment/rock: 305.730 m
Event(s):
333-C0018A * Latitude: 33.156992 * Longitude: 136.681480 * Elevation: -3084.3 m * Recovery: 271.44 m * Campaign: Exp333 (NanTroSEIZE Stage 2: Subduction Inputs 2 and Heat Flow) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 333 ScientistsDSDP/ODP/IODP sample designationSample top
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 333 Scientists[m CSF-B] Top Core depth (below sea floor)
Sample code/label 2Sample label 2Expedition 333 ScientistsDSDP/ODP/IODP sample designationSample bottom
Depth, bottom/maxDepth botmExpedition 333 Scientists[m CSF-A] Bottom Core depth (below sea floor)
Depth, bottom/maxDepth botmExpedition 333 Scientists[m CSF-B] Bottom Core depth (below sea floor)
Sample volumeSamp volcm3Expedition 333 Scientists
Time StampTime StampExpedition 333 ScientistsOf sampling
EthaneC2H6relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
10 EtheneC2H4relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
11 MethaneCH4relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
12 PropaneC3H8relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
13 PropeneC3H6relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
14 Isobutanei-C4H10relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
15 n-Butanen-C4H10relative unitsExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)
16 Time StampTime StampExpedition 333 ScientistsGas chromatography - Flame Ionization Detection (GC-FID)GC FID compound registration time-stamp
Size:
450 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(Sample top, DSDP/ODP/IODP sam...)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Sample label 2
(Sample bottom, DSDP/ODP/IODP ...)

Depth bot [m]
([m CSF-A] Bottom Core depth (...)

Depth bot [m]
([m CSF-B] Bottom Core depth (...)

Samp vol [cm3]

Time Stamp
(Of sampling)

C2H6 [relative units]
(Gas chromatography - Flame Io...)
10 
C2H4 [relative units]
(Gas chromatography - Flame Io...)
11 
CH4 [relative units]
(Gas chromatography - Flame Io...)
12 
C3H8 [relative units]
(Gas chromatography - Flame Io...)
13 
C3H6 [relative units]
(Gas chromatography - Flame Io...)
14 
i-C4H10 [relative units]
(Gas chromatography - Flame Io...)
15 
n-C4H10 [relative units]
(Gas chromatography - Flame Io...)
16 
Time Stamp
(GC FID compound registration ...)
333-C0018A-1H-1,75.00.7500.729333-C0018A-1H-1,79.00.7900.76852010-12-11T18:03:550.00000000000.00000000000002010-12-12T13:29:24
333-C0018A-2H-1,124.07.8907.816333-C0018A-2H-1,128.07.9307.85452010-12-12T03:22:300.00000000006.70134794100002010-12-12T13:30:07
333-C0018A-3H-1,137.017.52017.431333-C0018A-3H-1,141.017.56017.46852010-12-12T05:18:350.000000000012093.58911000000002010-12-12T13:30:50
333-C0018A-4H-1,146.027.11026.986333-C0018A-4H-1,150.027.15027.02352010-12-12T09:41:390.00000000007769.13748000000002010-12-12T13:31:32
333-C0018A-5H-1,137.536.52536.431333-C0018A-5H-1,141.536.56536.46852010-12-12T10:44:271.389364575018073.14798000000002010-12-12T13:32:40
333-C0018A-6H-1,136.546.01545.877333-C0018A-6H-1,140.546.05545.91352010-12-12T11:57:441.385488710015255.01086000000002010-12-12T13:33:20
333-C0018A-7H-1,136.055.51055.381333-C0018A-7H-1,140.055.55055.41752010-12-12T14:03:360.00000000007666.69741300000002010-12-12T15:13:42
333-C0018A-8H-2,142.565.33065.170333-C0018A-8H-2,146.565.37065.20652010-12-12T15:51:370.00000000005961.85879400000002010-12-13T11:07:04
333-C0018A-10H-2,137.082.04581.818333-C0018A-10H-2,141.082.08581.85452010-12-12T22:03:510.00000000005552.10785000000002010-12-13T11:08:24
333-C0018A-11H-2,132.091.61591.339333-C0018A-11H-2,136.091.65591.37452010-12-13T00:51:500.00000000004843.47753600000002010-12-13T11:09:01
333-C0018A-12H-2,119.5101.025100.893333-C0018A-12H-2,123.5101.065100.93052010-12-13T02:48:200.00000000004332.38854800000002010-12-13T11:09:59
333-C0018A-13H-3,136.0110.625110.290333-C0018A-13H-3,140.0110.665110.32352010-12-13T06:58:190.00000000003281.60433900000002010-12-13T11:10:43
333-C0018A-14H-2,135.5119.710119.708333-C0018A-14H-2,139.5119.750119.74852010-12-13T10:39:130.00000000005101.02858500000002010-12-13T11:11:14
333-C0018A-15H-2,114.5127.900127.747333-C0018A-15H-2,118.5127.940127.78352010-12-13T12:33:440.00000000002823.90999100000002010-12-14T18:15:24
333-C0018A-17H-1,136.5146.015145.918333-C0018A-17H-1,140.5146.055145.95552010-12-13T20:41:100.00000000005503.79988600000002010-12-15T05:17:07
333-C0018A-18H-1,124.0154.890154.816333-C0018A-18H-1,128.0154.930154.85452010-12-14T00:17:240.00000000004428.30185100000002010-12-15T05:19:49
333-C0018A-19H-1,133.5160.985160.774333-C0018A-19H-1,137.5161.025160.80752010-12-14T02:54:430.00000000005583.06655500000002010-12-14T18:13:35
333-C0018A-20H-2,125.5166.210166.141333-C0018A-20H-2,129.5166.250166.17952010-12-14T08:01:560.0000000000919.42640070000002010-12-14T18:21:13
333-C0018A-21H-1,136.5175.515175.432333-C0018A-21H-1,140.5175.555175.46952010-12-14T09:41:160.00000000004270.08106300000002010-12-14T18:17:18
333-C0018A-22H-1,42.0178.870178.870333-C0018A-22H-1,46.0178.910178.91052010-12-14T13:58:061.60773011107729.83951200000002010-12-14T18:22:34
333-C0018A-24T-1,136.5192.015192.015333-C0018A-24T-1,140.5192.055192.05552010-12-14T19:47:580.00000000002309.80810400000002010-12-15T02:31:49
333-C0018A-25T-1,137.0201.520201.520333-C0018A-25T-1,141.0201.560201.56052010-12-14T23:50:541.621508133019338.67092000000002010-12-15T02:37:05
333-C0018A-27T-2,142.5220.885220.885333-C0018A-27T-2,146.5220.925220.92552010-12-15T07:38:290.00000000006522.12470600000002010-12-15T17:20:46
333-C0018A-29T-1,134.5239.495239.495333-C0018A-29T-1,138.5239.535239.53552010-12-15T16:11:111.417280833014496.40482000000002010-12-15T17:24:07
333-C0018A-30T-1,137.5249.025249.025333-C0018A-30T-1,141.5249.065249.06552010-12-15T19:02:520.00000000005693.56179300000002010-12-15T21:03:20
333-C0018A-31X-1,113.5258.285258.285333-C0018A-31X-1,117.5258.325258.32552010-12-15T22:04:370.00000000009916.65084300000002010-12-17T12:14:08
333-C0018A-33X-4,0.0278.925278.925333-C0018A-33X-4,4.0278.965278.96552010-12-16T04:49:560.00000000007904.28741900000002010-12-17T12:19:04
333-C0018A-34X-3,33.5288.635288.635333-C0018A-34X-3,37.5288.675288.67552010-12-16T07:52:070.00000000008328.33718700000002010-12-17T12:21:32
333-C0018A-35X-2,134.0297.595297.390333-C0018A-35X-2,138.0297.635297.42752010-12-16T10:38:281.42291833605888.77738900000002010-12-17T12:23:39
333-C0018A-36X-2,81.0305.730305.730333-C0018A-36X-2,85.0305.770305.77052010-12-16T13:12:580.00000000006891.94423900000002010-12-17T12:24:43