Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2012): Thermal conductivity of IODP Hole 316-C0007D [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.782720
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Project(s):
Coverage:
Latitude: 33.021945 * Longitude: 136.798120
Date/Time Start: 2008-01-19T00:00:00 * Date/Time End: 2008-01-19T00:00:00
Minimum DEPTH, sediment/rock: 190.620 m * Maximum DEPTH, sediment/rock: 408.870 m
Event(s):
316-C0007D * Latitude: 33.021945 * Longitude: 136.798120 * Date/Time: 2008-01-19T00:00:00 * Elevation: -4049.0 m * Recovery: 87.93 m * Campaign: Exp316 (NanTroSEIZE Stage 1: Shallow Megaslay and Frontal Thrusts) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 35 cores; 318.5 m cored; 27.61 % recovery; 493.5 m drilled; 493.5 m penetrated
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Expedition 314/315/316 Scientists | DSDP/ODP/IODP sample designation | ||
2 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
3 | Depth, top/min | Depth top | m | Expedition 314/315/316 Scientists | [m CSF-B] Top Core depth (below sea floor) | |
4 | Comment | Comment | Expedition 314/315/316 Scientists | Probe type | ||
5 | Comment | Comment | Expedition 314/315/316 Scientists | Probe comment | ||
6 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Average |
7 | Comment | Comment | Expedition 314/315/316 Scientists | Horizonal measurement comment | ||
8 | Number | No | Expedition 314/315/316 Scientists | Number of runs | ||
9 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 1 |
10 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 2 |
11 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 3 |
12 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 4 |
13 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 5 |
14 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 6 |
15 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 7 |
16 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 8 |
17 | Conductivity, thermal | k | W/m/K | Expedition 314/315/316 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 9 |
18 | Name | Name | Expedition 314/315/316 Scientists | Probe number | ||
19 | Comment | Comment | Expedition 314/315/316 Scientists | Comments for run 1 to 10 | ||
20 | Time Stamp | Time Stamp | Expedition 314/315/316 Scientists | Registration |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
238 data points
Data
1 Sample label (DSDP/ODP/IODP sample designation) | 2 Depth sed [m] | 3 Depth top [m] ([m CSF-B] Top Core depth (bel...) | 4 Comment (Probe type) | 5 Comment (Probe comment) | 6 k [W/m/K] (Average, Quick Thermal Conduc...) | 7 Comment (Horizonal measurement comment) | 8 No (Number of runs) | 9 k [W/m/K] (Run 1, Quick Thermal Conducti...) | 10 k [W/m/K] (Run 2, Quick Thermal Conducti...) | 11 k [W/m/K] (Run 3, Quick Thermal Conducti...) | 12 k [W/m/K] (Run 4, Quick Thermal Conducti...) | 13 k [W/m/K] (Run 5, Quick Thermal Conducti...) | 14 k [W/m/K] (Run 6, Quick Thermal Conducti...) | 15 k [W/m/K] (Run 7, Quick Thermal Conducti...) | 16 k [W/m/K] (Run 8, Quick Thermal Conducti...) | 17 k [W/m/K] (Run 9, Quick Thermal Conducti...) | 18 Name (Probe number) | 19 Comment (Comments for run 1 to 10) | 20 Time Stamp (Registration) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
316-C0007D-3R-1,62.0 | 190.620 | 190.620 | VLQ 70 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.194 | 62 cm | 2008-01-20T00:20:11 | ||||||||||||
316-C0007D-3R-3,40.0 | 192.160 | 192.160 | VLQ 70 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.251 | 40 cm | 3 | 1.258 | 1.246 | 1.249 | V10305 | 40 cm | 2008-01-20T00:21:05 | ||||||
316-C0007D-4R-1,30.0 | 199.800 | 199.800 | VLQ 70 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.076 | 30 cm | 3 | 1.093 | 1.070 | 1.067 | V10305 | 30 cm | 2008-01-20T00:21:47 | ||||||
316-C0007D-5R-2,56.0 | 210.965 | 210.965 | VLQ 70 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.068 | 56 cm | 3 | 1.058 | 1.078 | 1.068 | V10305 | 56 cm | 2008-01-21T21:35:56 | ||||||
316-C0007D-8R-1,53.0 | 238.030 | 238.030 | VLQ 70 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.308 | 53 cm | 3 | 1.324 | 1.279 | 1.321 | V10305 | 53 cm | 2008-01-21T21:36:29 | ||||||
316-C0007D-8R-2,9.0 | 239.000 | 239.000 | VLQ 70 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.087 | 9 cm | 2 | 1.109 | 1.066 | V10305 | 9 cm | 2008-01-21T21:37:02 | |||||||
316-C0007D-19R-2,100.0 | 343.910 | 343.910 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.293 | probe oriented parallel to long axis | 2008-01-24T00:02:05 | ||||||||||||
316-C0007D-21R-1,95.0 | 361.450 | 361.450 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.037 | probe oriented parallel to long axis | 2008-01-24T00:05:52 | ||||||||||||
316-C0007D-22R-1,65.0 | 370.650 | 370.650 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.302 | probe oriented parallel to long axis | 5 | 1.311 | 1.304 | 1.299 | 1.303 | 1.296 | H10304 | 65-76 cm probe oriented parallel to long axis | 2008-01-24T00:07:17 | ||||
316-C0007D-22R-1,66.0 | 370.660 | 370.660 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.227 | probe oriented perpendicular to core axis | 9 | 1.237 | 1.215 | 1.226 | 1.224 | 1.238 | 1.230 | 1.236 | 1.223 | 1.219 | H10304 | 65-76 cm probe oriented perpendicular to core axis | 2008-01-24T00:08:16 |
316-C0007D-22R-4,37.0 | 374.630 | 374.630 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.326 | probe oriented parallel to core axis | 2008-01-24T00:09:21 | ||||||||||||
316-C0007D-22R-4,38.0 | 374.640 | 374.640 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.281 | probe oriented perpendicular to core axis | 5 | 1.276 | 1.284 | 1.275 | 1.269 | 1.302 | H10304 | 37-57 cm probe oriented perpendicular to core axis | 2010-09-29T07:41:10 | ||||
316-C0007D-23R-2,0.0 | 380.905 | 380.905 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.293 | probe oriented parallel to core axis | 2008-01-24T00:12:08 | ||||||||||||
316-C0007D-23R-2,1.0 | 380.915 | 380.915 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.315 | probe oriented perpendicular to core axis | 2008-01-24T00:13:19 | ||||||||||||
316-C0007D-23R-4,18.0 | 383.925 | 383.925 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.272 | probe parallel to core axis | 2008-01-24T00:14:27 | ||||||||||||
316-C0007D-23R-4,19.0 | 383.935 | 383.935 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.172 | probe perpendicular to core axis | 4 | 1.187 | 1.165 | 1.177 | 1.161 | H10304 | 18-47 cm, probe perpendicular to core axis | 2008-01-24T00:15:28 | |||||
316-C0007D-24R-1,65.0 | 389.650 | 389.650 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.321 | probe parallel to core axis | 9 | 1.389 | 1.320 | 1.250 | 1.319 | 1.317 | 1.318 | 1.323 | 1.321 | 1.336 | H10304 | 65-75 cm, probe parallel to core axis | 2008-01-24T00:16:23 |
316-C0007D-24R-1,66.0 | 389.660 | 389.660 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.010 | probe perpendicular to core axis | 2008-01-24T00:17:13 | ||||||||||||
316-C0007D-26R-1,86.0 | 408.860 | 408.860 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.299 | probe parallel to core axis | 7 | 1.262 | 1.306 | 1.302 | 1.294 | 1.307 | 1.315 | 1.309 | H10304 | 86-91 cm, probe parallel to core axis | 2008-01-24T17:04:52 | ||
316-C0007D-26R-1,87.0 | 408.870 | 408.870 | HLQ 88 | Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1. | 1.271 | probe perpendicular to core axis | 9 | 1.268 | 1.251 | 1.254 | 1.276 | 1.266 | 1.279 | 1.300 | 1.284 | 1.261 | H10304 | 86-91 cm, probe perpendicular to core axis | 2008-01-24T17:05:41 |