Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Delaney, Margaret Lois; Linn, L J (1993): (Appendix D) Bulk calcite minor element composition for ODP Site 130-806 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.780745, In supplement to: Delaney, ML; Linn, LJ (1993): Interstitial water and bulk calcite chemistry, Leg 130, and calcite recrystallization. In: Berger, WH; Kroenke, LW; Mayer, LA; et al. (eds.), Proceedings of the Ocean Drilling Program, Scientific Results, College Station, TX (Ocean Drilling Program), 130, 561-572, https://doi.org/10.2973/odp.proc.sr.130.038.1993

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 0.318500 * Longitude: 159.361000
Date/Time Start: 1990-02-18T21:00:00 * Date/Time End: 1990-02-25T19:00:00
Minimum DEPTH, sediment/rock: 4.45 m * Maximum DEPTH, sediment/rock: 765.10 m
Event(s):
130-806B  * Latitude: 0.318500 * Longitude: 159.361000 * Date/Time Start: 1990-02-18T21:00:00 * Date/Time End: 1990-02-23T01:30:00 * Elevation: -2519.9 m * Penetration: 743.1 m * Recovery: 666.36 m * Location: North Pacific Ocean * Campaign: Leg130 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 78 cores; 743.1 m cored; 0 m drilled; 89.7 % recovery
130-806C  * Latitude: 0.318500 * Longitude: 159.361000 * Date/Time Start: 1990-02-23T01:30:00 * Date/Time End: 1990-02-25T19:00:00 * Elevation: -2520.8 m * Penetration: 776.4 m * Recovery: 523.62 m * Location: North Pacific Ocean * Campaign: Leg130 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 62 cores; 587.6 m cored; 0 m drilled; 89.1 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Event labelEvent
Sample code/labelSample labelDelaney, Margaret Lois
DEPTH, sediment/rockDepth sedmGeocode – mbsf
AGEAgeka BPGeocode
Strontium/Calcium ratioSr/Cammol/molDelaney, Margaret Loistreated
Magnesium/Calcium ratioMg/Cammol/molDelaney, Margaret Loistreated
Manganese/Calcium ratioMn/Cammol/molDelaney, Margaret Loistreated
Iron/Calcium ratioFe/Cammol/molDelaney, Margaret Loistreated
Strontium/Calcium ratioSr/Cammol/molDelaney, Margaret Loisbulk leach
10 Magnesium/Calcium ratioMg/Cammol/molDelaney, Margaret Loisbulk leach
11 Manganese/Calcium ratioMn/Cammol/molDelaney, Margaret Loisbulk leach
12 Iron/Calcium ratioFe/Cammol/molDelaney, Margaret Loisbulk leach
Size:
270 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Event

Sample label

Depth sed [m]
(mbsf)

Age [ka BP]

Sr/Ca [mmol/mol]
(treated)

Mg/Ca [mmol/mol]
(treated)

Mn/Ca [mmol/mol]
(treated)

Fe/Ca [mmol/mol]
(treated)

Sr/Ca [mmol/mol]
(bulk leach)
10 
Mg/Ca [mmol/mol]
(bulk leach)
11 
Mn/Ca [mmol/mol]
(bulk leach)
12 
Fe/Ca [mmol/mol]
(bulk leach)
130-806B 130-806B-1H-3,145-1504.452001.663.140.6500.0501.715.920.3160.055
130-806B130-806B-2H-4,145-15012.456001.792.120.6320.0471.874.910.6450.050
130-806B130-806B-3H-4,145-15011.9510001.742.290.5790.0311.865.170.5130.041
130-806B130-806B-4H-4,145-15031.4515001.612.780.4970.0541.705.250.5230.062
130-806B130-806B-5H-4,145-15040.9519001.612.670.6290.0321.714.860.4990.038
130-806B130-806B-6H-4,145-15050.4522001.712.600.4360.0391.795.140.4070.034
130-806B130-806B-9H-4,145-15078.9531001.672.620.3540.0211.764.870.2840.031
130-806B130-806B-12H-4,145-150107.4538001.463.490.4380.0411.605.540.3760.028
130-806B130-806B-15H-4,145-150135.9544001.642.960.1980.0131.814.890.1640.014
130-806B130-806B-18H-4,145-150164.4551001.573.160.2290.0391.725.200.1920.094
130-806B130-806B-21H-4,145-150192.9557001.463.830.2560.0171.565.760.1910.023
130-806B130-806B-24H-4,145-150221.4563001.443.700.1580.0131.514.910.1360.014
130-806B130-806B-27H-4,145-150249.9569001.483.310.1490.0131.584.850.1250.010
130-806B130-806B-30H-5,140-150279.9575001.353.800.1850.0161.475.170.1370.013
130-806B130-806B-33H-4,145-150306.9581001.184.480.2030.0141.305.660.2550.027
130-806B130-806B-36X-4,145-150335.6587001.423.580.2070.0171.554.830.1770.022
130-806B130-806B-39X-4,145-150364.7097001.403.200.2860.0231.464.620.2360.022
130-806B130-806B-42X-3,140-150392.30107001.592.870.2410.0321.694.030.2070.031
130-806B130-806B-45X-3,140-150421.30117001.443.620.1650.0301.534.720.1710.034
130-806B130-806B-48X-3,140-150450.20127001.284.140.2360.0471.374.940.1990.055
130-806B130-806B-52X-3,140-150487.00141001.224.540.2920.1621.295.240.2280.175
130-806B130-806B-54X-5,140-150509.30152001.303.980.3060.1351.384.840.2630.138
130-806B130-806B-57X-2,140-150533.80165001.264.150.2040.2501.335.260.2060.240
130-806B130-806B-60X-4,0-7564.40180001.373.940.2870.2631.454.690.2250.242
130-806B130-806B-63X-4,140-150594.90196001.333.870.2370.2461.394.660.2000.227
130-806B130-806B-66X-4,140-150623.80208001.373.670.1740.0961.484.530.1560.099
130-806B130-806B-69X-3,140-150650.90218001.303.550.2480.2701.434.470.1870.264
130-806B130-806B-72X-3,140-150679.90229001.353.400.2340.2261.444.180.1820.224
130-806B130-806B-78X-2,0-10706.00239001.263.240.1810.3051.354.140.1680.261
130-806C 130-806C-61X-4,140-150765.10253001.343.200.2640.2871.403.810.1990.264