Binns, Raymond A (2006): (Table T2) Geochemistry of massive and semimassive sulfides of ODP Site 193-1189 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.779235, In supplement to: Binns, RA (2006): Data report: Geochemistry of massive and semimassive sulfides from Site 1189, Ocean Drilling Program Leg 193. In: Barriga, FJAS; Binns, RA; Miller, DJ; Herzig, PM (eds.) Proceedings of the Ocean Drilling Program, Scientific Results, College Station, TX (Ocean Drilling Program), 193, 1-22, https://doi.org/10.2973/odp.proc.sr.193.206.2006
Always quote citation above when using data! You can download the citation in several formats below.
Project(s):
Ocean Drilling Program (ODP)
Coverage:
Median Latitude: -3.720650 * Median Longitude: 151.675000 * South-bound Latitude: -3.720700 * West-bound Longitude: 151.674900 * North-bound Latitude: -3.720600 * East-bound Longitude: 151.675100
Date/Time Start: 2000-11-22T08:30:00 * Date/Time End: 2000-12-26T17:00:00
Minimum DEPTH, sediment/rock: 31.00 m * Maximum DEPTH, sediment/rock: 107.70 m
Event(s):
193-1189A * Latitude: -3.720700 * Longitude: 151.674900 * Date/Time Start: 2000-11-22T08:30:00 * Date/Time End: 2000-11-23T20:45:00 * Elevation: -1690.2 m * Penetration: 125.8 m * Recovery: 8.58 m * Location: Bismarck Sea * Campaign: Leg193 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 13 cores; 125.8 m cored; 0 m drilled; 6.8 % recovery
193-1189B * Latitude: -3.720600 * Longitude: 151.675100 * Date/Time Start: 2000-12-22T07:45:00 * Date/Time End: 2000-12-26T17:00:00 * Elevation: -1681.7 m * Penetration: 206 m * Recovery: 13.69 m * Location: Bismarck Sea * Campaign: Leg193 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 18 cores; 175 m cored; 31 m drilled; 7.8 % recovery
Comment:
Curated sediment depth is given in mbsf.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | ||||
2 | Sample code/label | Sample label | Binns, Raymond A | DSDP/ODP/IODP sample designation | ||
3 | Piece | Piece | Binns, Raymond A | |||
4 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
5 | Sample code/label 2 | Sample label 2 | Binns, Raymond A | CSIRO no. | ||
6 | Lithium | Li | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
7 | Beryllium | Be | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 2 mg/kg |
8 | Sodium | Na | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
9 | Sodium | Na | % | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.01 % |
10 | Magnesium | Mg2+ | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
11 | Aluminium | Al | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
12 | Silicon | Si | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | closed-vessel dissolution |
13 | Phosphorus | P | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 50 mg/kg |
14 | Sulfur, total | TS | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
15 | Potassium | K | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 50 mg/kg |
16 | Potassium | K | % | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.2 % |
17 | Calcium | Ca2+ | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
18 | Calcium | Ca | % | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.5 % |
19 | Scandium | Sc | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
20 | Scandium | Sc | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | detection limit = 0.1 mg/kg |
21 | Scandium | Sc | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.1 mg/kg |
22 | Titanium | Ti | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
23 | Vanadium | V | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
24 | Vanadium | V | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
25 | Chromium | Cr | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
26 | Chromium | Cr | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
27 | Chromium | Cr | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 10 mg/kg |
28 | Manganese | Mn | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
29 | Iron | Fe | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
30 | Iron | Fe | % | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | |
31 | Cobalt | Co | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
32 | Cobalt | Co | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | #999 = over detection range |
33 | Cobalt | Co | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | |
34 | Nickel | Ni | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 10 mg/kg |
35 | Nickel | Ni | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
36 | Copper | Cu | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
37 | Zinc | Zn | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
38 | Zinc | Zn | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 100 mg/kg |
39 | Gallium | Ga | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
40 | Germanium | Ge | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
41 | Arsenic | As | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
42 | Arsenic | As | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | #999 = over detection range |
43 | Arsenic | As | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | |
44 | Selenium | Se | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | |
45 | Bromine | Br | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 1 mg/kg |
46 | Rubidium | Rb | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
47 | Rubidium | Rb | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 20 mg/kg |
48 | Strontium | Sr | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
49 | Yttrium | Y | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 2 mg/kg |
50 | Yttrium | Y | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
51 | Zirconium | Zr | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
52 | Zirconium | Zr | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 500 mg/kg |
53 | Molybdenum | Mo | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
54 | Molybdenum | Mo | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
55 | Molybdenum | Mo | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | |
56 | Silver | Ag | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
57 | Silver | Ag | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 5 mg/kg |
58 | Cadmium | Cd | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 5 mg/kg |
59 | Cadmium | Cd | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
60 | Cadmium | Cd | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 20 mg/kg |
61 | Indium | In | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
62 | Antimony | Sb | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 50 mg/kg |
63 | Antimony | Sb | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
64 | Antimony | Sb | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.2 mg/kg |
65 | Tellurium | Te | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | detection limit = 0.09 mg/kg |
66 | Tellurium | Te | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 10 mg/kg |
67 | Caesium | Cs | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | detection limit = 0.01 mg/kg |
68 | Caesium | Cs | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 2 mg/kg |
69 | Barium | Ba | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
70 | Barium | Ba | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 100 mg/kg |
71 | Lanthanum | La | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
72 | Lanthanum | La | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
73 | Lanthanum | La | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.5 mg/kg |
74 | Cerium | Ce | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
75 | Cerium | Ce | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 2 mg/kg |
76 | Praseodymium | Pr | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
77 | Neodymium | Nd | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
78 | Samarium | Sm | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
79 | Samarium | Sm | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | |
80 | Europium | Eu | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
81 | Europium | Eu | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.5 mg/kg |
82 | Gadolinium | Gd | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
83 | Terbium | Tb | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
84 | Dysprosium | Dy | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
85 | Holmium | Ho | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
86 | Erbium | Er | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
87 | Thulium | Tm | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
88 | Ytterbium | Yb | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | detection limit = 2 mg/kg |
89 | Ytterbium | Yb | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
90 | Ytterbium | Yb | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.5 mg/kg |
91 | Lutetium | Lu | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
92 | Lutetium | Lu | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.2 mg/kg |
93 | Hafnium | Hf | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 1 mg/kg |
94 | Tantalum | Ta | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 1 mg/kg |
95 | Tungsten | W | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 2 mg/kg |
96 | Iridium | Ir | ng/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 20000 ng/kg |
97 | Gold | Au | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.005 mg/kg |
98 | Mercury | Hg | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 5 mg/kg |
99 | Thallium | Tl | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
100 | Lead | Pb | mg/kg | Binns, Raymond A | Inductively coupled plasma atomic emission spectroscope (ICP-AES) | |
101 | Lead | Pb | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
102 | Bismuth | Bi | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
103 | Thorium | Th | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | detection limit = 0.005 mg/kg |
104 | Thorium | Th | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 0.5 mg/kg |
105 | Uranium | U | mg/kg | Binns, Raymond A | Inductively coupled plasma - mass spectrometry (ICP-MS) | |
106 | Uranium | U | mg/kg | Binns, Raymond A | Instrumental neutron activation analysis (INAA) | detection limit = 2 mg/kg |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
235 data points