Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Pringle, Malcolm S (1992): (Table 4) Incremental heating and age determination for whole-rock samples from ODP Hole 129-801C tholeiitic basalts [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.779180, In supplement to: Pringle, MS (1992): Radiometric ages of basaltic basement recovered at Sites 800, 801, and 802, Leg 129, western Pacific Ocean. In: Larson, RL; Lancelot, Y; et al. (eds.), Proceedings of the Ocean Drilling Program, Scientific Results, College Station, TX (Ocean Drilling Program), 129, 389-404, https://doi.org/10.2973/odp.proc.sr.129.130.1992

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 18.642300 * Longitude: 156.359800
Date/Time Start: 1990-01-06T11:48:00 * Date/Time End: 1990-01-16T07:15:00
Minimum Elevation: -5685.0 m * Maximum Elevation: -5685.0 m
Event(s):
129-801C * Latitude: 18.642300 * Longitude: 156.359800 * Date/Time Start: 1990-01-06T11:48:00 * Date/Time End: 1990-01-16T07:15:00 * Elevation: -5685.0 m * Penetration: 594.3 m * Recovery: 60.6 m * Location: North Pacific Ocean * Campaign: Leg129 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 12 cores; 100.6 m cored; 0 m drilled; 60.2 % recovery
Comment:
1100°C = heat each of the previously heated basalt fragments to 1100°C, measure individually. Fuse previously heated basalt fragments, measure in three groups of three fragments each.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelPringle, Malcolm SDSDP/ODP/IODP sample designation
Sample commentSample commentPringle, Malcolm Stemperature of each incremental heating step (°C) using a resistance furnace for heating
Argon-40/Argon-3940Ar/39ArPringle, Malcolm Sdecay corrected
Argon-37/Argon-3937Ar/39ArPringle, Malcolm Sdecay corrected
Argon-36/Argon-3936Ar/39Ar10-3Pringle, Malcolm Sdecay corrected
Argon-4040Ar%Pringle, Malcolm Sradiogenic
Argon-4040Ar%Pringle, Malcolm Spotassium-derived
Argon-3939Ar%Pringle, Malcolm Scalcium-derived
Argon-3636Ar%Pringle, Malcolm Scalcium-derived
10 Potassium/Calcium ratioK/CaPringle, Malcolm Scalcium-derived
11 Argon-3939Ar%Pringle, Malcolm S
12 Age, datedAge datedkaPringle, Malcolm Sapparent; Lambda E = 0.581E-10/yr, Lambda B = 4.692E-10/yr
13 Age, dated standard deviationAge dated std dev±Pringle, Malcolm Sapparent; Lambda E = 0.581E-10/yr, Lambda B = 4.692E-10/yr, Errors are standard deviation of analytical precision
14 CommentCommentPringle, Malcolm S
Size:
262 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Sample comment
(temperature of each increment...)

40Ar/39Ar
(decay corrected)

37Ar/39Ar
(decay corrected)

36Ar/39Ar [10-3]
(decay corrected)

40Ar [%]
(radiogenic)

40Ar [%]
(potassium-derived)

39Ar [%]
(calcium-derived)

36Ar [%]
(calcium-derived)
10 
K/Ca
(calcium-derived)
11 
39Ar [%]
12 
Age dated [ka]
(apparent; Lambda E = 0.581E-1...)
13 
Age dated std dev [±]
(apparent; Lambda E = 0.581E-1...)
14 
Comment
129-801C-10R-5,53-5860033.82027.20046.91065.40.01.815.60.017735.01772001300Basalt core, J = 0.004584, total gas age = 164.1 ± 2.0 Ma
129-801C-10R-5,53-5870024.04046.15026.67082.40.03.146.50.010316.31616004800
129-801C-10R-5,53-5880021.92032.42016.91188.90.02.251.60.014814.01577005600
129-801C-10R-5,53-5890020.81051.73019.57591.90.03.571.10.009122.11568003800
129-801C-10R-5,53-58100018.046280.30080.43091.70.118.893.80.00147.016120011400
129-801C-10R-5,53-58140016.281366.300109.75079.60.124.589.80.00105.613670014500
129-801C-10R-6,21-2660039.26014.85595.27031.30.01.04.20.03307.12109004800Basalt, J = 0.009995, total gas age = 175.8 ± 1.1 Ma
129-801C-10R-6,21-2670016.42220.59022.57069.30.11.424.50.023014.51969001900
129-801C-10R-6,21-261100: #112.64836.18018.79778.80.12.451.80.01324.11753002800
129-801C-10R-6,21-261100: #213.48833.53020.97073.70.12.243.00.01437.31747002100
129-801C-10R-6,21-261100: #311.77345.86018.96283.30.13.165.10.01047.41738002100
129-801C-10R-6,21-261100: #412.72340.68021.06076.40.12.752.00.01179.41718001900
129-801C-10R-6,21-261100: #512.84340.69021.50075.60.12.750.90.01179.31716001900
129-801C-10R-6,21-261100: #612.56344.58022.09076.20.13.054.30.01075.31696002400
129-801C-10R-6,21-261100: #712.52337.82019.95076.90.12.551.00.01268.51698001900
129-801C-10R-6,21-261100: #812.84939.86021.90074.20.12.749.00.01206.21686002200
129-801C-10R-6,21-261100: #913.31639.95023.51071.60.12.745.70.01194.91685002400
129-801C-10R-6,21-26Fuse: #1-#312.329149.55054.49065.80.110.073.80.00294.81556004500
129-801C-10R-6,21-26Fuse: #4-#611.659144.92050.30071.20.19.777.50.00316.11587004200
129-801C-10R-6,21-26Fuse: #7-#911.735176.75059.82069.00.111.879.50.00245.21585005100