Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Fulthorpe, Craig S; Hoyanagi, Koichi; Blum, Peter; Expedition 317 Scientists (2012): Interstitial water analysis from IODP Hole 317-U1354C [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.779102

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Fulthorpe, Craig S; Hoyanagi, Koichi; Blum, Peter; Expedition 317 Scientists (2011): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 317, https://doi.org/10.2204/iodp.proc.317.2011
IODP/USIO (2012): LIMS Database. Ocean Drilling Programm, Texas A&M University, College station TX 77845-9547, USA, https://web.iodp.tamu.edu/LORE/
Coverage:
Latitude: -44.847470 * Longitude: 171.786800
Date/Time Start: 2009-12-30T12:45:00 * Date/Time End: 2010-02-01T12:00:00
Minimum DEPTH, sediment/rock: 82.50 m * Maximum DEPTH, sediment/rock: 318.19 m
Event(s):
317-U1354C * Latitude: -44.847470 * Longitude: 171.786800 * Date/Time Start: 2009-12-30T12:45:00 * Date/Time End: 2010-02-01T12:00:00 * Elevation: -113.4 m * Penetration: 384.2 m * Recovery: 133.4 m * Campaign: Exp317 (Canterbury Basin) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 36 cores; 319.2 m cored; 42 % recovered; 65 m drilled; 384.2 m penetrated
Comment:
Geocode = Top depth CSF-A (m)
Chemical methods for interstitial water analysis aboard JOIDES Resolution; ODP Technical Note 15: http://www-odp.tamu.edu/publications/tnotes/tn15/technote15.pdf
Analysis of major and trace elements in rocks, sediments, and interstitial waters by ICP-AES; ODP Technical Note 29 : http://www-odp.tamu.edu/publications/tnotes/tn29/TNOTE_29.PDF
Introduction to shipboard organic geochemistry on the JOIDES Resolution; ODP Technical Note 30: http://www-odp.tamu.edu/publications/tnotes/tn30/TNOTE_30.PDF
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 317 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 317 ScientistsTop depth CSF-B (m)
Depth, bottom/maxDepth botmExpedition 317 ScientistsBottom depth CSF-A (m)
Depth, bottom/maxDepth botmExpedition 317 ScientistsBottom depth CSF-B (m)
Alkalinity, totalATmmol(eq)/lExpedition 317 ScientistsTitration
CalciumCammol/lExpedition 317 ScientistsIon chromatography
ChlorideCl-mmol/lExpedition 317 ScientistsIon chromatography
MagnesiumMgmmol/lExpedition 317 ScientistsIon chromatography
10 pHpHExpedition 317 ScientistspH, Electrode
11 Phosphate[PO4]3-mmol/lExpedition 317 ScientistsDiscrete Analyzer (DA)
12 PotassiumKmmol/lExpedition 317 ScientistsIon chromatography
13 SalinitySalExpedition 317 ScientistsRefractometer
14 SodiumNammol/lExpedition 317 ScientistsIon chromatography
15 Sulfate[SO4]2-mmol/lExpedition 317 ScientistsIon chromatography
Size:
270 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
(Top depth CSF-B (m))

Depth bot [m]
(Bottom depth CSF-A (m))

Depth bot [m]
(Bottom depth CSF-B (m))

AT [mmol(eq)/l]
(Titration)

Ca [mmol/l]
(Ion chromatography)

Cl- [mmol/l]
(Ion chromatography)

Mg [mmol/l]
(Ion chromatography)
10 
pH
(pH, Electrode)
11 
[PO4]3- [mmol/l]
(Discrete Analyzer (DA))
12 
K [mmol/l]
(Ion chromatography)
13 
Sal
(Refractometer)
14 
Na [mmol/l]
(Ion chromatography)
15 
[SO4]2- [mmol/l]
(Ion chromatography)
317-U1354C-4X-3,14082.5081.0282.5081.025.1608.868599.68232.7847.2301.3954.60736526.2225.187
317-U1354C-5X-3,11486.4486.4486.4486.445.0589.993638.28535.2357.4981.4884.80235561.6146.816
317-U1354C-6X-4,8797.2797.2797.2797.274.6699.681587.67133.4897.5081.2724.43635516.2497.862
317-U1354C-7X-2,140104.40104.40104.40104.403.4569.464586.75233.8317.5891.0024.19335517.1698.014
317-U1354C-8X-3,110110.60110.60110.60110.604.07810.540618.16236.1947.3310.5943.93035545.2139.172
317-U1354C-9X-3,140120.50120.50120.50120.503.98410.451589.10535.0747.5750.7333.52735520.2369.115
317-U1354C-9X-3,140120.50120.50120.50120.500.817
317-U1354C-10X-4,140131.50131.50131.50131.503.21010.881607.63736.5397.5353.39835534.45010.437
317-U1354C-11X-5,140142.50142.28142.50142.282.85011.122602.82937.4467.3960.7873.05335531.02611.476
317-U1354C-12X-5,90151.60151.60151.60151.602.94211.316582.54536.9957.5010.6633.14636510.89312.511
317-U1354C-13X-4,140160.20160.20160.20160.202.65411.822599.51738.9567.5230.5483.15135524.23513.992
317-U1354C-14X-1,132165.22165.22165.22165.222.55313.001619.85541.7827.4890.7714.21636541.47316.245
317-U1354C-15X-3,140177.90177.90177.90177.902.36413.096610.32841.1427.4740.4863.51436530.97816.412
317-U1354C-18X-2,140205.20205.20205.20205.203.7769.306620.92537.6737.3840.8642.82235538.0513.586
317-U1354C-19X-2,140214.70214.70214.70214.704.2498.614625.68036.8057.6440.7022.87535541.9800.000
317-U1354C-21X-3,140235.40235.25235.40235.253.00811.569624.00035.0957.3660.4942.85236534.9120.000
317-U1354C-22X-3,140244.90244.90244.90244.902.61212.446635.73435.8997.5010.4473.00037548.8880.000
317-U1354C-27X-2,135291.35291.35291.35291.352.20714.327638.61136.0737.2090.4323.35738545.0090.000
317-U1354C-28X-1,112299.22299.22299.22299.222.07415.139682.48237.3017.4120.4324.26138580.6150.000
317-U1354C-30X-1,119318.19318.19318.19318.192.17115.623694.28437.2057.6660.5324.71038590.8980.000