Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Fulthorpe, Craig S; Hoyanagi, Koichi; Blum, Peter; Expedition 317 Scientists (2012): Core-section summary from IODP Hole 317-U1354B [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.778780

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Fulthorpe, Craig S; Hoyanagi, Koichi; Blum, Peter; Expedition 317 Scientists (2011): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 317, https://doi.org/10.2204/iodp.proc.317.2011
IODP/USIO (2012): LIMS Database. Ocean Drilling Programm, Texas A&M University, College station TX 77845-9547, USA, https://web.iodp.tamu.edu/LORE/
Coverage:
Latitude: -44.847270 * Longitude: 171.786780
Date/Time Start: 2009-12-29T23:00:00 * Date/Time End: 2009-12-30T12:45:00
Minimum Elevation: -113.4 m * Maximum Elevation: -113.4 m
Event(s):
317-U1354B * Latitude: -44.847270 * Longitude: 171.786780 * Date/Time Start: 2009-12-29T23:00:00 * Date/Time End: 2009-12-30T12:45:00 * Elevation: -113.4 m * Penetration: 77.2 m * Recovery: 77.5 m * Campaign: Exp317 (Canterbury Basin) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 15 cores; 77.2 m cored; 100 % recovered; 0 m drilled; 77.2 m penetrated
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 317 ScientistsDSDP/ODP/IODP sample designation
Section Top in meters below surfaceTopmbsfExpedition 317 Scientists[m CSF-A]
Section Bot in meters below surfaceBotmbsfExpedition 317 Scientists[m CSF-A]
Record lengthLengthmExpedition 317 Scientists
Curated LengthCLmExpedition 317 Scientists
NumberNoExpedition 317 ScientistsOf catwalk samples
NumberNoExpedition 317 ScientistsOf section half samples
CommentCommentExpedition 317 Scientists
Size:
532 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Top [mbsf]
([m CSF-A])

Bot [mbsf]
([m CSF-A])

Length [m]

CL [m]

No
(Of catwalk samples)

No
(Of section half samples)

Comment
317-U1354B-1H-10.001.501.501.50747
317-U1354B-1H-21.503.001.501.50041
317-U1354B-1H-33.004.061.061.06041
317-U1354B-1H-CC4.064.140.080.0810All to PAL
317-U1354B-2H-14.105.601.501.50040
317-U1354B-2H-25.607.101.501.50017
317-U1354B-2H-37.108.601.501.50122
317-U1354B-2H-48.609.921.321.32121
317-U1354B-2H-59.9211.141.221.22024
317-U1354B-2H-611.1411.680.540.5409
317-U1354B-2H-CC11.6811.730.050.0510All to PAL
317-U1354B-3H-111.7012.080.380.3802
317-U1354B-3H-CC12.0812.130.050.0510All to PAL
317-U1354B-4H-112.1013.601.501.50117
317-U1354B-4H-213.6015.101.501.50021
317-U1354B-4H-315.1016.601.501.50024
317-U1354B-4H-416.6017.641.041.04021
317-U1354B-4H-CC17.6417.690.050.0520All to PAL
317-U1354B-5H-117.7019.201.501.50126
317-U1354B-5H-219.2020.311.111.11024
317-U1354B-5H-CC20.3120.370.060.0611All to PAL
317-U1354B-6H-120.4020.880.480.4806
317-U1354B-6H-CC20.8820.930.050.0510All to PAL
317-U1354B-7H-120.9021.880.980.98114
317-U1354B-7H-221.8822.991.111.11015
317-U1354B-7H-322.9924.321.331.33014
317-U1354B-7H-424.3225.561.241.24019
317-U1354B-7H-525.5626.500.940.94012
317-U1354B-7H-CC26.5026.550.050.0510All to PAL
317-U1354B-8H-126.6028.101.501.50011
317-U1354B-8H-228.1029.601.501.50122
317-U1354B-8H-329.6031.101.501.50022
317-U1354B-8H-431.1032.601.501.50014
317-U1354B-8H-532.6033.240.640.64011
317-U1354B-8H-CC33.2433.500.260.2611
317-U1354B-9H-133.5035.001.501.50019
317-U1354B-9H-235.0036.501.501.50017
317-U1354B-9H-336.5038.001.501.50116
317-U1354B-9H-438.0039.501.501.50015
317-U1354B-9H-539.5040.601.101.10015
317-U1354B-9H-640.6041.200.600.6008
317-U1354B-9H-CC41.2041.510.310.3111
317-U1354B-10H-141.5043.001.501.50016
317-U1354B-10H-243.0044.501.501.50018
317-U1354B-10H-344.5046.001.501.50119
317-U1354B-10H-446.0047.501.501.50018
317-U1354B-10H-547.5049.001.501.50019
317-U1354B-10H-649.0050.071.071.07024
317-U1354B-10H-CC50.0750.340.270.2712
317-U1354B-11H-150.5052.001.501.50022
317-U1354B-11H-252.0053.501.501.50016
317-U1354B-11H-353.5055.001.501.50120
317-U1354B-11H-455.0056.501.501.50019
317-U1354B-11H-556.5057.470.970.97014
317-U1354B-11H-CC57.4757.780.310.3113
317-U1354B-12H-157.5058.420.920.92014
317-U1354B-12H-258.4259.921.501.50121
317-U1354B-12H-359.9261.421.501.50022
317-U1354B-12H-461.4262.170.750.75014
317-U1354B-12H-CC62.1762.490.320.3213
317-U1354B-13H-162.5064.001.501.50023
317-U1354B-13H-264.0065.501.501.50033
317-U1354B-13H-365.5067.001.501.50121
317-U1354B-13H-467.0068.501.501.50018
317-U1354B-13H-568.5069.591.091.09016
317-U1354B-13H-669.5970.200.610.61012
317-U1354B-13H-CC70.2070.450.250.2511
317-U1354B-14H-170.5072.001.501.50117
317-U1354B-14H-272.0073.391.391.39123
317-U1354B-14H-CC73.3973.610.220.2211
317-U1354B-15H-173.5074.741.241.24030
317-U1354B-15H-274.7475.480.740.74015
317-U1354B-15H-375.4875.990.510.51013
317-U1354B-15H-475.9977.251.261.2611
317-U1354B-15H-CC77.2577.300.050.0510