Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0017D [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.777018

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Coverage:
Latitude: 27.791748 * Longitude: 126.912028
Minimum DEPTH, sediment/rock: 66.135 m * Maximum DEPTH, sediment/rock: 144.630 m
Event(s):
331-C0017D * Latitude: 27.791748 * Longitude: 126.912028 * Elevation: -1129.5 m * Recovery: 50.59 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
CommentCommentExpedition 331 ScientistsSample comment
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Average
CommentCommentExpedition 331 ScientistsHorizon comment
NumberNoExpedition 331 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
CommentCommentExpedition 331 ScientistsRun 1 comment
10 Time StampTime StampExpedition 331 ScientistsRegistration
Size:
390 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Comment
(Sample comment)

k [W/m/K]
(Average, Quick Thermal Conduc...)

Comment
(Horizon comment)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

Comment
(Run 1 comment)
10 
Time Stamp
(Registration)
331-C0017D-1H-5,50.066.13565.992VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.71310.713INTERVAL = 50 CM2010-09-29T03:42:37
331-C0017D-1H-5,120.066.83566.675VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.616TC was corrected because LET was lower than 4.10.616INTERVAL = 120 CM2010-10-22T04:11:23
331-C0017D-1H-6,50.067.54567.369VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.88410.884INTERVAL = 50 CM2010-09-29T03:45:44
331-C0017D-1H-7,30.068.76068.555Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.96410.964INTERVAL = 30 CM2010-10-02T19:55:32
331-C0017D-2H-1,122.070.42070.405Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.534TC was corrected because LET was lower than 4.10.534INTERVAL = 122 CM2010-10-22T04:13:52
331-C0017D-2H-2,105.071.66071.629VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.69810.698INTERVAL = 105 CM2010-09-29T04:06:03
331-C0017D-2H-3,65.072.67572.632Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.13111.131INTERVAL = 65 CM2010-09-29T04:07:26
331-C0017D-2H-4,122.074.65574.587VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.060TC was corrected because LET was lower than 4.11.060INTERVAL = 122 CM2010-10-22T04:14:51
331-C0017D-2H-5,5.074.89574.824Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.76110.761INTERVAL = 5 CM2010-09-30T03:46:18
331-C0017D-2H-5,70.075.54575.466VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.774TC was corrected because LET was lower than 4.10.774INTERVAL = 70 CM2010-10-22T04:16:38
331-C0017D-2H-6,49.076.74076.646VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.147TC was corrected because LET was lower than 4.11.147INTERVAL = 49 CM2010-10-22T04:17:59
331-C0017D-2H-7,31.077.97077.861Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.558TC was corrected because LET was lower than 4.10.558INTERVAL = 31 CM; HEATING PWR = 22010-10-22T04:19:47
331-C0017D-6X-1,30.094.50094.500Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.264TC was corrected because LET was lower than 4.11.264INTERVAL = 30 CM; HEATING PWR = 32010-10-22T04:20:40
331-C0017D-6X-2,15.095.63095.630VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.36111.361INTERVAL = 15 CM2010-09-30T03:55:09
331-C0017D-6X-CC,23.096.02596.025VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.26711.267INTERVAL = 23 CM2010-09-30T03:56:00
331-C0017D-7H-2,50.0105.610105.512Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.522TC was corrected because LET was lower than 4.11.522INTERVAL = 50 CM; HEATING PWR = 32010-10-22T04:21:40
331-C0017D-7H-3,50.0107.020106.850Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.351TC was corrected because LET was lower than 4.11.351INTERVAL = 50 CM; HEATING PWR = 32010-10-22T04:22:40
331-C0017D-7H-4,30.0108.220107.988VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.28411.284INTERVAL = 30 CM2010-09-30T03:59:26
331-C0017D-7H-4,100.0108.920108.652VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.189TC was corrected because LET was lower than 4.11.189INTERVAL = 100 CM2010-10-22T04:23:43
331-C0017D-7H-5,50.0109.835109.520Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.24111.241INTERVAL = 50 CM, HEATING PWR = 32010-09-30T04:00:48
331-C0017D-7H-5,120.0110.535110.184Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.41311.413INTERVAL = 120 CM, HEATING PWR = 32010-09-30T04:02:10
331-C0017D-7H-6,100.0111.750111.337VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.23211.232INTERVAL = 100 CM2010-09-30T04:02:42
331-C0017D-7H-7,20.0112.045111.617Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.19711.197INTERVAL = 20 CM, HEATING PWR = 32010-09-30T04:03:18
331-C0017D-7H-CC,15.0112.355111.911VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.28011.280INTERVAL = 15 CM2010-09-30T04:01:25
331-C0017D-9X-1,5.0121.750121.745Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.35511.355INTERVAL = 5 CM, HEATING PWR = 32010-09-30T04:03:56
331-C0017D-9X-2,50.0122.310122.251VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.21611.216INTERVAL = 50 CM2010-09-30T04:04:43
331-C0017D-9X-2,90.0122.710122.612VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.27111.271INTERVAL = 90 CM2010-09-30T04:05:14
331-C0017D-9X-3,50.0123.630123.442Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.60211.602INTERVAL = 50 CM, HEATING PWR = 32010-09-30T04:05:45
331-C0017D-9X-4,50.0124.970124.652Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.498TC was corrected because LET was lower than 4.11.498INTERVAL = 50 CM; HEATING PWR = 32010-10-22T04:24:44
331-C0017D-9X-5,10.0125.980125.564VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.70911.709INTERVAL = 10 CM2010-10-02T19:59:14
331-C0017D-9X-5,100.0126.880126.376VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.59911.599INTERVAL = 100 CM2010-09-30T04:11:09
331-C0017D-9X-6,50.0127.790127.198Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.63911.639INTERVAL = 50 CM, HEATING PWR = 32010-09-30T04:11:38
331-C0017D-9X-7,50.0129.200128.470Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.501TC was corrected because LET was lower than 4.11.501INTERVAL = 50 CM; HEATING PWR = 32010-10-22T04:25:40
331-C0017D-9X-8,50.0130.605129.739VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.62811.628INTERVAL = 50 CM2010-09-30T04:13:13
331-C0017D-9X-CC,20.0131.415130.470VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.54511.545INTERVAL = 20 CM2010-09-30T04:14:29
331-C0017D-10X-1,50.0131.200131.200Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.33811.338INTERVAL = 50 CM, HEATING PWR = 32010-09-30T04:15:13
331-C0017D-10X-2,50.0132.615132.615VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.58311.583INTERVAL = 50 CM2010-09-30T04:15:42
331-C0017D-10X-3,50.0134.025134.025Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.165TC was corrected because LET was lower than 4.11.165INTERVAL = 50 CM; HEATING PWR = 32010-10-22T04:26:45
331-C0017D-10X-4,50.0135.435135.435VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.55611.556INTERVAL = 50 CM2010-09-30T04:17:02
331-C0017D-10X-5,20.0136.545136.545Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.94711.947INTERVAL = 20 CM, HEATING PWR = 32010-10-02T20:00:43
331-C0017D-10X-CC,50.0137.220137.220VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.38111.381INTERVAL = 50 CM2010-09-30T04:18:09
331-C0017D-11X-1,60.0140.800140.800Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.54611.546INTERVAL = 60 CM2010-09-30T04:19:55
331-C0017D-11X-1,128.0141.480141.480VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.37011.370INTERVAL = 128 CM2010-09-30T04:20:42
331-C0017D-11X-2,60.0142.205142.205VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.39611.396INTERVAL = 60 CM2010-09-30T04:21:14
331-C0017D-11X-3,36.0143.370143.370Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.26711.267INTERVAL = 36 CM2010-09-30T04:21:50
331-C0017D-11X-3,111.0144.120144.120Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.990TC was corrected because LET was lower than 4.10.990INTERVAL = 111 CM2010-10-22T04:28:08
331-C0017D-11X-CC,29.0144.630144.630VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.93610.936INTERVAL = 29 CM2010-09-30T04:23:06