Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0017B [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776908
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0017B, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0017B/
Project(s):
Coverage:
Latitude: 27.791712 * Longitude: 126.911960
Minimum DEPTH, sediment/rock: 9.460 m * Maximum DEPTH, sediment/rock: 18.445 m
Event(s):
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Expedition 331 Scientists | DSDP/ODP/IODP sample designation | ||
2 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
3 | Depth, top/min | Depth top | m | Expedition 331 Scientists | [m CSF-B] Top Core depth (below sea floor) | |
4 | Comment | Comment | Expedition 331 Scientists | Sample comment | ||
5 | Conductivity, thermal | k | W/m/K | Expedition 331 Scientists | Quick Thermal Conductivity Meter QTM-500 | Average |
6 | Comment | Comment | Expedition 331 Scientists | Horizon comment | ||
7 | Number | No | Expedition 331 Scientists | Number of runs | ||
8 | Conductivity, thermal | k | W/m/K | Expedition 331 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 1 |
9 | Comment | Comment | Expedition 331 Scientists | Run 1 comment | ||
10 | Time Stamp | Time Stamp | Expedition 331 Scientists | Registration |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
128 data points
Data
1 Sample label (DSDP/ODP/IODP sample designation) | 2 Depth sed [m] | 3 Depth top [m] ([m CSF-B] Top Core depth (bel...) | 4 Comment (Sample comment) | 5 k [W/m/K] (Average, Quick Thermal Conduc...) | 6 Comment (Horizon comment) | 7 No (Number of runs) | 8 k [W/m/K] (Run 1, Quick Thermal Conducti...) | 9 Comment (Run 1 comment) | 10 Time Stamp (Registration) |
---|---|---|---|---|---|---|---|---|---|
331-C0017B-1H-1,66.0 | 9.460 | 9.446 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.112 | 1 | 1.112 | 1570 | 2010-09-28T23:44:17 | |
331-C0017B-1H-1,118.0 | 9.980 | 9.955 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.176 | TC was corrected because LET was lower than 4. | 1 | 1.176 | INTERVAL = 118 CM | 2010-10-22T03:50:49 |
331-C0017B-1H-2,25.0 | 10.455 | 10.419 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.992 | 1 | 0.992 | INTERVAL = 25 CM | 2010-09-28T23:48:14 | |
331-C0017B-1H-2,120.0 | 11.405 | 11.349 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.025 | TC was corrected because LET was lower than 4. | 1 | 1.025 | INTERVAL = 120 CM | 2010-10-22T03:52:05 |
331-C0017B-1H-3,30.0 | 11.925 | 11.857 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.023 | 1 | 1.023 | INTERVAL = 30 CM | 2010-09-28T23:50:38 | |
331-C0017B-1H-3,105.0 | 12.675 | 12.591 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.046 | TC was corrected because LET was lower than 4. | 1 | 1.046 | INTERVAL = 105 CM | 2010-10-22T03:53:09 |
331-C0017B-1H-4,43.0 | 13.465 | 13.364 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.068 | 1 | 1.068 | INTERVAL = 43 CM | 2010-10-22T04:41:36 | |
331-C0017B-1H-4,126.0 | 14.295 | 14.176 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.079 | TC was corrected because LET was lower than 4. | 1 | 1.079 | INTERVAL = 126 CM | 2010-10-22T03:55:06 |
331-C0017B-1H-5,25.0 | 14.685 | 14.558 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.110 | 1 | 1.110 | INTERVAL = 25 CM | 2010-09-28T23:53:12 | |
331-C0017B-1H-5,105.0 | 15.485 | 15.340 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.115 | TC was corrected because LET was lower than 4. | 1 | 1.115 | INTERVAL = 105 CM | 2010-10-22T03:56:12 |
331-C0017B-1H-6,29.0 | 16.145 | 15.986 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.989 | 1 | 0.989 | INTERVAL = 29 CM | 2010-09-28T23:54:29 | |
331-C0017B-1H-6,110.0 | 16.955 | 16.779 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.119 | TC was corrected because LET was lower than 4. | 1 | 1.119 | INTERVAL = 110 CM | 2010-10-22T03:57:05 |
331-C0017B-1H-7,20.0 | 17.465 | 17.278 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.134 | 1 | 1.134 | INTERVAL = 20 CM | 2010-09-28T23:55:45 | |
331-C0017B-1H-7,80.0 | 18.065 | 17.865 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.092 | TC was corrected because LET was lower than 4. | 1 | 1.092 | INTERVAL = 80 CM | 2010-10-22T03:59:06 |
331-C0017B-1H-CC,15.0 | 18.445 | 18.236 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.936 | TC was corrected because LET was lower than 4. | 1 | 0.936 | INTERVAL = 15 CM | 2010-10-22T04:02:09 |