Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0017A [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776895

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0017A, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0017A/
Coverage:
Latitude: 27.791717 * Longitude: 126.911960
Minimum DEPTH, sediment/rock: 0.500 m * Maximum DEPTH, sediment/rock: 8.455 m
Event(s):
331-C0017A * Latitude: 27.791717 * Longitude: 126.911960 * Elevation: -1129.0 m * Recovery: 8.8 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
CommentCommentExpedition 331 ScientistsSample comment
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Average
CommentCommentExpedition 331 ScientistsHorizon comment
NumberNoExpedition 331 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
CommentCommentExpedition 331 ScientistsRun 1 comment
10 Time StampTime StampExpedition 331 ScientistsRegistration
Size:
115 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Comment
(Sample comment)

k [W/m/K]
(Average, Quick Thermal Conduc...)

Comment
(Horizon comment)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

Comment
(Run 1 comment)
10 
Time Stamp
(Registration)
331-C0017A-1H-1,50.00.5000.500Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.916TC was corrected because LET was lower than 4.10.916INTERVAL = 50 CM2010-10-22T03:02:37
331-C0017A-1H-1,109.01.0901.090VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.939TC was corrected because LET was lower than 4.10.939INTERVAL = 109 CM2010-10-22T03:31:00
331-C0017A-1H-2,30.01.7001.700Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.000TC was corrected because LET was lower than 4.11.000INTERVAL = 30 CM2010-10-22T05:04:44
331-C0017A-1H-2,110.02.5002.500VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.036TC was corrected because LET was lower than 4.11.036INTERVAL = 110 CM2010-10-22T03:34:36
331-C0017A-1H-3,15.02.9602.960Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.027TC was corrected because LET was lower than 4.11.027INTERVAL = 15 CM2010-10-22T03:35:46
331-C0017A-1H-3,100.03.8103.810VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.82710.827INTERVAL = 100 CM2010-09-28T22:05:56
331-C0017A-1H-4,15.04.3704.370Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.997TC was corrected because LET was lower than 4.10.997INTERVAL = 15 CM2010-10-22T03:37:00
331-C0017A-1H-4,100.05.2205.220VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.789TC was corrected because LET was lower than 4.10.789INTERVAL = 100 CM2010-10-22T03:39:20
331-C0017A-1H-5,40.06.0406.040Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.918TC was corrected because LET was lower than 4.10.918INTERVAL = 40 CM2010-10-22T03:40:25
331-C0017A-1H-5,115.06.7906.790VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.020TC was corrected because LET was lower than 4.11.020INTERVAL = 115 CM2010-10-22T03:46:53
331-C0017A-1H-6,25.07.2857.285Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.978TC was corrected because LET was lower than 4.10.978INTERVAL = 25 CM2010-10-22T03:48:40
331-C0017A-1H-6,110.08.1358.135VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.984TC was corrected because LET was lower than 4.10.984INTERVAL = 110 CM2010-10-22T03:49:35
331-C0017A-1H-CC,3.08.4558.455Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.77510.775INTERVAL = 3 CM2010-09-28T22:12:49