Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0016B [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776856

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0016B, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0016B/
Coverage:
Latitude: 27.790897 * Longitude: 126.896433
Minimum DEPTH, sediment/rock: 0.36 m * Maximum DEPTH, sediment/rock: 27.62 m
Event(s):
331-C0016B * Latitude: 27.790897 * Longitude: 126.896433 * Elevation: -995.0 m * Recovery: 1.74 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
CommentCommentExpedition 331 ScientistsSample comment
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Average
NumberNoExpedition 331 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
CommentCommentExpedition 331 ScientistsRun 1 comment
Time StampTime StampExpedition 331 ScientistsRegistration
Size:
32 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Comment
(Sample comment)

k [W/m/K]
(Average, Quick Thermal Conduc...)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

Comment
(Run 1 comment)

Time Stamp
(Registration)
331-C0016B-1L-1,36.00.360.36Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1.7.44417.444INTERVAL = 36-43 CM2010-10-22T04:05:00
331-C0016B-2L-CC,22.09.229.22Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1.3.68013.680INTERVAL=21.5-30cm2010-10-22T07:03:48
331-C0016B-3L-1,10.027.1027.10Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1.3.31313.313INTERVAL = 10-14 CM2010-10-22T04:06:18
331-C0016B-3L-CC,3.027.6227.62Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1.10.180110.189INTERVAL = 3-7 CM2010-10-22T04:06:54