Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0014G [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776789
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0014G, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0014G/
Project(s):
Coverage:
Latitude: 27.790275 * Longitude: 126.900772
Minimum DEPTH, sediment/rock: 1.000 m * Maximum DEPTH, sediment/rock: 113.870 m
Event(s):
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Expedition 331 Scientists | DSDP/ODP/IODP sample designation | ||
2 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
3 | Depth, top/min | Depth top | m | Expedition 331 Scientists | [m CSF-B] Top Core depth (below sea floor) | |
4 | Comment | Comment | Expedition 331 Scientists | Sample comment | ||
5 | Conductivity, thermal | k | W/m/K | Expedition 331 Scientists | Quick Thermal Conductivity Meter QTM-500 | Average |
6 | Comment | Comment | Expedition 331 Scientists | Horizon comment | ||
7 | Number | No | Expedition 331 Scientists | Number of runs | ||
8 | Conductivity, thermal | k | W/m/K | Expedition 331 Scientists | Quick Thermal Conductivity Meter QTM-500 | Run 1 |
9 | Comment | Comment | Expedition 331 Scientists | Run 1 comment | ||
10 | Time Stamp | Time Stamp | Expedition 331 Scientists | Registration |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
539 data points
Data
1 Sample label (DSDP/ODP/IODP sample designation) | 2 Depth sed [m] | 3 Depth top [m] ([m CSF-B] Top Core depth (bel...) | 4 Comment (Sample comment) | 5 k [W/m/K] (Average, Quick Thermal Conduc...) | 6 Comment (Horizon comment) | 7 No (Number of runs) | 8 k [W/m/K] (Run 1, Quick Thermal Conducti...) | 9 Comment (Run 1 comment) | 10 Time Stamp (Registration) |
---|---|---|---|---|---|---|---|---|---|
331-C0014G-1H-1,100.0 | 1.000 | 0.968 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.977 | TC was corrected because LET was lower than 4. | 1 | 0.977 | INTERVAL = 100 CM | 2010-10-22T02:22:54 |
331-C0014G-1H-2,100.0 | 2.420 | 2.344 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.974 | TC was corrected because LET was lower than 4. | 1 | 0.974 | INTERVAL = 100 CM | 2010-10-22T02:24:10 |
331-C0014G-1H-3,50.0 | 3.330 | 3.225 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.995 | TC was corrected because LET was lower than 4. | 1 | 0.995 | INTERVAL = 50 CM | 2010-10-22T02:25:15 |
331-C0014G-1H-4,50.0 | 4.725 | 4.576 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.878 | TC was corrected because LET was lower than 4. | 1 | 0.878 | INTERVAL = 50 CM | 2010-10-22T02:26:25 |
331-C0014G-1H-5,10.0 | 5.740 | 5.559 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.039 | TC was corrected because LET was lower than 4. | 1 | 1.039 | INTERVAL = 10 CM | 2010-10-22T02:27:35 |
331-C0014G-1H-5,80.0 | 6.440 | 6.237 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.770 | TC was corrected because LET was lower than 4. | 1 | 0.770 | INTERVAL = 80 CM | 2010-10-22T02:28:49 |
331-C0014G-2H-4,61.0 | 14.000 | 13.834 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.902 | TC was corrected because LET was lower than 4. | 1 | 0.902 | HEAT PWR = 3; INTERVAL = 61 cm | 2010-10-22T02:30:13 |
331-C0014G-2H-5,48.0 | 15.275 | 15.065 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.699 | TC was corrected because LET was lower than 4. | 1 | 0.699 | HEAT PWR = 3; INTERVAL = 48 CM | 2010-10-22T02:35:56 |
331-C0014G-2H-6,43.0 | 16.645 | 16.388 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.034 | 1 | 1.034 | HEAT PWR = 3, INTERVAL=43cm | 2010-09-23T04:21:04 | |
331-C0014G-2H-6,118.0 | 17.395 | 17.112 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.171 | TC was corrected because LET was lower than 4. | 1 | 1.171 | HEATING PWR=4; INTERVAL=118 CM | 2010-10-22T02:39:08 |
331-C0014G-2H-7,7.0 | 17.730 | 17.435 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.046 | TC was corrected because LET was lower than 4. | 1 | 1.046 | INTERVAL = 7 CM | 2010-10-22T02:41:47 |
331-C0014G-2H-7,60.0 | 18.260 | 17.947 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.883 | 1 | 0.883 | HEATING PWR=4; INTERVAL = 60 CM | 2010-10-22T04:40:20 | |
331-C0014G-2H-7,92.0 | 18.580 | 18.256 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.214 | TC was corrected because LET was lower than 4. | 1 | 1.214 | HEATING PWR=3; INTERVAL = 92 CM | 2010-10-22T02:45:04 |
331-C0014G-2H-CC,16.0 | 18.870 | 18.536 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.194 | TC was corrected because LET was lower than 4. | 1 | 1.194 | HEAT PWR = 3; INTERVAL = 16 CM | 2010-10-22T02:47:15 |
331-C0014G-3H-1,7.0 | 18.770 | 18.764 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.595 | 1 | 1.595 | HEAT PWR = 3, INTERVAL=7cm | 2010-09-23T04:30:25 | |
331-C0014G-3H-1,53.0 | 19.230 | 19.188 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.986 | TC was corrected because LET was lower than 4. | 1 | 0.986 | HEATING PWR=3; INTERVAL = 53 CM | 2010-10-22T02:52:29 |
331-C0014G-3H-2,27.0 | 19.610 | 19.538 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.913 | TC was corrected because LET was lower than 4. | 1 | 0.913 | HEAT PWR = 3; INTERVAL=27 CM | 2010-10-22T02:55:39 |
331-C0014G-3H-2,111.0 | 20.450 | 20.313 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.037 | TC was corrected because LET was lower than 4. | 1 | 1.037 | HEATING PWR=3; INTERVAL = 111 CM | 2010-10-22T02:58:12 |
331-C0014G-3H-3,7.0 | 20.820 | 20.653 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.988 | 1 | 0.988 | HEAT PWR = 3, INTERVAL=7cm | 2010-09-23T04:35:20 | |
331-C0014G-3H-4,29.0 | 21.460 | 21.243 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.873 | TC was corrected because LET was lower than 4. | 1 | 0.873 | HEAT PWR = 3; INTERVAL = 29 CM | 2010-10-22T02:59:26 |
331-C0014G-3H-4,111.0 | 22.280 | 21.999 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.121 | TC was corrected because LET was lower than 4. | 1 | 1.121 | HEATING PWR=3; INTERVAL = 111 CM | 2010-10-22T03:00:50 |
331-C0014G-3H-5,18.0 | 22.760 | 22.441 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.125 | TC was corrected because LET was lower than 4. | 1 | 1.125 | HEAT PWR = 3; INTERVAL = 18 CM | 2010-10-22T03:02:25 |
331-C0014G-3H-5,87.0 | 23.450 | 23.077 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.867 | TC was corrected because LET was lower than 4. | 1 | 0.867 | HEATING PWR=3; INTERVAL = 87 CM | 2010-10-22T03:04:20 |
331-C0014G-3H-6,32.0 | 24.300 | 23.860 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.017 | TC was corrected because LET was lower than 4. | 1 | 1.017 | HEAT PWR = 3; INTERVAL= 32 CM | 2010-10-22T03:28:21 |
331-C0014G-3H-7,12.0 | 24.590 | 24.127 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.759 | 1 | 0.759 | HEATING PWR=3, INTERVAL=12cm | 2010-09-23T04:41:14 | |
331-C0014G-3H-8,45.0 | 25.645 | 25.099 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.695 | 1 | 1.695 | HEAT PWR = 3, INTERVAL= 45 cm | 2010-09-23T04:43:30 | |
331-C0014G-3H-8,115.0 | 26.345 | 25.744 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.938 | 1 | 1.938 | HEATING PWR=3, INTERVAL=115 cm | 2010-09-23T17:12:28 | |
331-C0014G-3H-9,25.0 | 26.905 | 26.260 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2.184 | 1 | 2.184 | HEAT PWR = 3, INTERVAL= 25 cm | 2010-09-23T17:13:13 | |
331-C0014G-3H-9,90.0 | 27.555 | 26.859 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.942 | TC was corrected because LET was lower than 4. | 1 | 0.942 | HEAT PWR = 3; INTERVAL= 90 CM | 2010-10-22T03:29:45 |
331-C0014G-3H-10,20.0 | 27.865 | 27.145 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.751 | 1 | 1.751 | HEATING PWR=3, INTERVAL= 20 cm | 2010-09-23T17:16:56 | |
331-C0014G-3H-CC,17.0 | 28.380 | 27.619 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.708 | TC was corrected because LET was lower than 4. | 1 | 0.708 | HEAT PWR = 3; INTERVAL=17cm | 2010-10-22T03:30:48 |
331-C0014G-4H-1,36.0 | 28.560 | 28.560 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.033 | 1 | 1.033 | HEATING PWR=3, INTERVAL= 36 cm | 2010-09-23T17:23:31 | |
331-C0014G-4H-2,63.0 | 29.515 | 29.515 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.996 | TC was corrected because LET was lower than 4. | 1 | 0.996 | INTERVAL = 63 CM | 2010-10-22T03:32:04 |
331-C0014G-4H-6,50.0 | 31.915 | 31.915 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.200 | TC was corrected because LET was lower than 4. | 1 | 1.200 | INTERVAL = 50 CM | 2010-10-22T03:33:46 |
331-C0014G-4H-7,30.0 | 32.725 | 32.725 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.060 | TC was corrected because LET was lower than 4. | 1 | 1.060 | INTERVAL = 30 CM | 2010-10-22T03:35:10 |
331-C0014G-4H-10,40.0 | 35.850 | 35.850 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.153 | TC was corrected because LET was lower than 4. | 1 | 1.153 | INTERVAL = 40 CM | 2010-10-22T03:36:14 |
331-C0014G-4H-11,30.0 | 36.755 | 36.755 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.054 | TC was corrected because LET was lower than 4. | 1 | 1.054 | INTERVAL = 30 CM | 2010-10-22T03:37:47 |
331-C0014G-5H-3,50.0 | 38.535 | 38.535 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.985 | TC was corrected because LET was lower than 4. | 1 | 0.985 | INTERVAL = 50 CM | 2010-10-22T07:02:58 |
331-C0014G-6H-4,40.0 | 49.755 | 48.353 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.492 | TC was corrected because LET was lower than 4. | 1 | 1.492 | INTERVAL = 40 CM | 2010-10-22T03:42:32 |
331-C0014G-9X-1,100.0 | 55.200 | 55.200 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.450 | TC was corrected because LET was lower than 4. | 1 | 1.450 | INTERVAL = 100 CM | 2010-10-22T03:58:03 |
331-C0014G-13T-1,31.0 | 67.010 | 67.010 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.346 | 1 | 1.346 | INTERVAL =31 CM | 2010-09-23T17:32:34 | |
331-C0014G-13T-1,95.0 | 67.650 | 67.650 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2.786 | 1 | 2.786 | INTERVAL = 95 CM | 2010-09-23T17:33:13 | |
331-C0014G-13T-2,42.0 | 68.120 | 68.120 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.573 | 1 | 1.573 | INTERVAL =42 CM | 2010-09-23T17:34:09 | |
331-C0014G-13T-3,50.0 | 69.205 | 69.205 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.338 | 1 | 1.338 | INTERVAL = 50 CM | 2010-09-23T17:34:50 | |
331-C0014G-13T-4,27.0 | 69.975 | 69.975 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.655 | 1 | 1.655 | INTERVAL = 27 CM | 2010-09-23T17:36:16 | |
331-C0014G-13T-CC,5.0 | 70.120 | 70.120 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2.113 | 1 | 2.113 | INTERVAL =5CM | 2010-09-23T17:39:04 | |
331-C0014G-14T-1,16.0 | 71.360 | 71.360 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.464 | 1 | 1.464 | INTERVAL =16CM | 2010-09-23T17:51:11 | |
331-C0014G-14T-2,64.0 | 72.315 | 72.315 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.624 | 1 | 1.624 | INTERVAL = 64 CM | 2010-09-23T17:52:22 | |
331-C0014G-14T-3,12.0 | 72.810 | 72.810 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.387 | TC was corrected because LET was lower than 4. | 1 | 1.387 | INTERVAL = 12CM | 2010-10-22T04:00:09 |
331-C0014G-16T-1,20.0 | 76.100 | 76.100 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.495 | 1 | 1.495 | INTERVAL = 20 CM | 2010-09-23T18:05:06 | |
331-C0014G-16T-2,54.0 | 77.225 | 77.225 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2.148 | 1 | 2.148 | INTERVAL =54 CM | 2010-09-23T18:03:15 | |
331-C0014G-16T-CC,26.0 | 77.945 | 77.945 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 0.542 | TC was corrected because LET was lower than 4. | 1 | 0.542 | INTERVAL = 26 CM | 2010-10-22T04:01:10 |
331-C0014G-17T-1,20.0 | 80.400 | 80.400 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.059 | 1 | 1.059 | INTERVAL =20 CM | 2010-09-23T19:14:55 | |
331-C0014G-17T-2,50.0 | 81.110 | 81.110 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.211 | TC was corrected because LET was lower than 4. | 1 | 1.211 | INTERVAL = 50 CM | 2010-10-22T04:02:03 |
331-C0014G-17T-4,50.0 | 83.125 | 83.125 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.226 | 1 | 1.226 | INTERVAL = 50 CM | 2010-09-23T19:16:59 | |
331-C0014G-18T-2,50.0 | 85.515 | 85.515 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.061 | 1 | 1.061 | INTERVAL = 50 CM | 2010-09-23T19:18:02 | |
331-C0014G-18T-3,50.0 | 86.515 | 86.515 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.136 | TC was corrected because LET was lower than 4. | 1 | 1.136 | INTERVAL = 50 CM | 2010-10-22T04:03:16 |
331-C0014G-18T-4,50.0 | 87.520 | 87.520 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.110 | TC was corrected because LET was lower than 4. | 1 | 1.110 | INTERVAL = 50 CM | 2010-10-22T04:04:06 |
331-C0014G-24T-2,79.0 | 110.490 | 110.490 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 2.099 | 1 | 2.099 | INTERVAL = 79 CM | 2010-09-23T19:21:48 | |
331-C0014G-24T-3,20.0 | 110.900 | 110.900 | VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.738 | 1 | 1.738 | INTERVAL = 20 CM | 2010-09-23T19:22:17 | |
331-C0014G-24T-CC,28.0 | 113.070 | 113.070 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.714 | 1 | 1.714 | INTERVAL = 28 CM | 2010-09-23T19:23:00 | |
331-C0014G-24T-CC,40.0 | 113.190 | 113.190 | Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1. | 4.500 | 1 | 4.500 | INTERVAL = 40 CM | 2010-09-23T19:23:31 | |
331-C0014G-25T-1,17.0 | 113.870 | 113.870 | Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1. | 1.710 | 1 | 1.710 | INTERVAL = 17 CM | 2010-09-23T19:24:00 |