Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0014G [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776789

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0014G, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0014G/
Coverage:
Latitude: 27.790275 * Longitude: 126.900772
Minimum DEPTH, sediment/rock: 1.000 m * Maximum DEPTH, sediment/rock: 113.870 m
Event(s):
331-C0014G * Latitude: 27.790275 * Longitude: 126.900772 * Elevation: -1059.8 m * Recovery: 74.4 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
CommentCommentExpedition 331 ScientistsSample comment
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Average
CommentCommentExpedition 331 ScientistsHorizon comment
NumberNoExpedition 331 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
CommentCommentExpedition 331 ScientistsRun 1 comment
10 Time StampTime StampExpedition 331 ScientistsRegistration
Size:
539 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Comment
(Sample comment)

k [W/m/K]
(Average, Quick Thermal Conduc...)

Comment
(Horizon comment)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

Comment
(Run 1 comment)
10 
Time Stamp
(Registration)
331-C0014G-1H-1,100.01.0000.968Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.977TC was corrected because LET was lower than 4.10.977INTERVAL = 100 CM2010-10-22T02:22:54
331-C0014G-1H-2,100.02.4202.344VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.974TC was corrected because LET was lower than 4.10.974INTERVAL = 100 CM2010-10-22T02:24:10
331-C0014G-1H-3,50.03.3303.225Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.995TC was corrected because LET was lower than 4.10.995INTERVAL = 50 CM2010-10-22T02:25:15
331-C0014G-1H-4,50.04.7254.576VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.878TC was corrected because LET was lower than 4.10.878INTERVAL = 50 CM2010-10-22T02:26:25
331-C0014G-1H-5,10.05.7405.559Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.039TC was corrected because LET was lower than 4.11.039INTERVAL = 10 CM2010-10-22T02:27:35
331-C0014G-1H-5,80.06.4406.237VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.770TC was corrected because LET was lower than 4.10.770INTERVAL = 80 CM2010-10-22T02:28:49
331-C0014G-2H-4,61.014.00013.834Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.902TC was corrected because LET was lower than 4.10.902HEAT PWR = 3; INTERVAL = 61 cm2010-10-22T02:30:13
331-C0014G-2H-5,48.015.27515.065Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.699TC was corrected because LET was lower than 4.10.699HEAT PWR = 3; INTERVAL = 48 CM2010-10-22T02:35:56
331-C0014G-2H-6,43.016.64516.388Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.03411.034HEAT PWR = 3, INTERVAL=43cm2010-09-23T04:21:04
331-C0014G-2H-6,118.017.39517.112VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.171TC was corrected because LET was lower than 4.11.171HEATING PWR=4; INTERVAL=118 CM2010-10-22T02:39:08
331-C0014G-2H-7,7.017.73017.435Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.046TC was corrected because LET was lower than 4.11.046INTERVAL = 7 CM2010-10-22T02:41:47
331-C0014G-2H-7,60.018.26017.947VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.88310.883HEATING PWR=4; INTERVAL = 60 CM2010-10-22T04:40:20
331-C0014G-2H-7,92.018.58018.256VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.214TC was corrected because LET was lower than 4.11.214HEATING PWR=3; INTERVAL = 92 CM2010-10-22T02:45:04
331-C0014G-2H-CC,16.018.87018.536Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.194TC was corrected because LET was lower than 4.11.194HEAT PWR = 3; INTERVAL = 16 CM2010-10-22T02:47:15
331-C0014G-3H-1,7.018.77018.764Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.59511.595HEAT PWR = 3, INTERVAL=7cm2010-09-23T04:30:25
331-C0014G-3H-1,53.019.23019.188VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.986TC was corrected because LET was lower than 4.10.986HEATING PWR=3; INTERVAL = 53 CM2010-10-22T02:52:29
331-C0014G-3H-2,27.019.61019.538Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.913TC was corrected because LET was lower than 4.10.913HEAT PWR = 3; INTERVAL=27 CM2010-10-22T02:55:39
331-C0014G-3H-2,111.020.45020.313VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.037TC was corrected because LET was lower than 4.11.037HEATING PWR=3; INTERVAL = 111 CM2010-10-22T02:58:12
331-C0014G-3H-3,7.020.82020.653Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.98810.988HEAT PWR = 3, INTERVAL=7cm2010-09-23T04:35:20
331-C0014G-3H-4,29.021.46021.243Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.873TC was corrected because LET was lower than 4.10.873HEAT PWR = 3; INTERVAL = 29 CM2010-10-22T02:59:26
331-C0014G-3H-4,111.022.28021.999VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.121TC was corrected because LET was lower than 4.11.121HEATING PWR=3; INTERVAL = 111 CM2010-10-22T03:00:50
331-C0014G-3H-5,18.022.76022.441Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.125TC was corrected because LET was lower than 4.11.125HEAT PWR = 3; INTERVAL = 18 CM2010-10-22T03:02:25
331-C0014G-3H-5,87.023.45023.077VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.867TC was corrected because LET was lower than 4.10.867HEATING PWR=3; INTERVAL = 87 CM2010-10-22T03:04:20
331-C0014G-3H-6,32.024.30023.860Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.017TC was corrected because LET was lower than 4.11.017HEAT PWR = 3; INTERVAL= 32 CM2010-10-22T03:28:21
331-C0014G-3H-7,12.024.59024.127VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.75910.759HEATING PWR=3, INTERVAL=12cm2010-09-23T04:41:14
331-C0014G-3H-8,45.025.64525.099Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.69511.695HEAT PWR = 3, INTERVAL= 45 cm2010-09-23T04:43:30
331-C0014G-3H-8,115.026.34525.744VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.93811.938HEATING PWR=3, INTERVAL=115 cm2010-09-23T17:12:28
331-C0014G-3H-9,25.026.90526.260Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.18412.184HEAT PWR = 3, INTERVAL= 25 cm2010-09-23T17:13:13
331-C0014G-3H-9,90.027.55526.859Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.942TC was corrected because LET was lower than 4.10.942HEAT PWR = 3; INTERVAL= 90 CM2010-10-22T03:29:45
331-C0014G-3H-10,20.027.86527.145VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.75111.751HEATING PWR=3, INTERVAL= 20 cm2010-09-23T17:16:56
331-C0014G-3H-CC,17.028.38027.619Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.708TC was corrected because LET was lower than 4.10.708HEAT PWR = 3; INTERVAL=17cm2010-10-22T03:30:48
331-C0014G-4H-1,36.028.56028.560VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.03311.033HEATING PWR=3, INTERVAL= 36 cm2010-09-23T17:23:31
331-C0014G-4H-2,63.029.51529.515Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.996TC was corrected because LET was lower than 4.10.996INTERVAL = 63 CM2010-10-22T03:32:04
331-C0014G-4H-6,50.031.91531.915Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.200TC was corrected because LET was lower than 4.11.200INTERVAL = 50 CM2010-10-22T03:33:46
331-C0014G-4H-7,30.032.72532.725VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.060TC was corrected because LET was lower than 4.11.060INTERVAL = 30 CM2010-10-22T03:35:10
331-C0014G-4H-10,40.035.85035.850VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.153TC was corrected because LET was lower than 4.11.153INTERVAL = 40 CM2010-10-22T03:36:14
331-C0014G-4H-11,30.036.75536.755Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.054TC was corrected because LET was lower than 4.11.054INTERVAL = 30 CM2010-10-22T03:37:47
331-C0014G-5H-3,50.038.53538.535Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.985TC was corrected because LET was lower than 4.10.985INTERVAL = 50 CM2010-10-22T07:02:58
331-C0014G-6H-4,40.049.75548.353Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.492TC was corrected because LET was lower than 4.11.492INTERVAL = 40 CM2010-10-22T03:42:32
331-C0014G-9X-1,100.055.20055.200Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.450TC was corrected because LET was lower than 4.11.450INTERVAL = 100 CM2010-10-22T03:58:03
331-C0014G-13T-1,31.067.01067.010Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.34611.346INTERVAL =31 CM2010-09-23T17:32:34
331-C0014G-13T-1,95.067.65067.650VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.78612.786INTERVAL = 95 CM2010-09-23T17:33:13
331-C0014G-13T-2,42.068.12068.120Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.57311.573INTERVAL =42 CM2010-09-23T17:34:09
331-C0014G-13T-3,50.069.20569.205VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.33811.338INTERVAL = 50 CM2010-09-23T17:34:50
331-C0014G-13T-4,27.069.97569.975VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.65511.655INTERVAL = 27 CM2010-09-23T17:36:16
331-C0014G-13T-CC,5.070.12070.120Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.11312.113INTERVAL =5CM2010-09-23T17:39:04
331-C0014G-14T-1,16.071.36071.360Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.46411.464INTERVAL =16CM2010-09-23T17:51:11
331-C0014G-14T-2,64.072.31572.315VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.62411.624INTERVAL = 64 CM2010-09-23T17:52:22
331-C0014G-14T-3,12.072.81072.810VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.387TC was corrected because LET was lower than 4.11.387INTERVAL = 12CM2010-10-22T04:00:09
331-C0014G-16T-1,20.076.10076.100VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.49511.495INTERVAL = 20 CM2010-09-23T18:05:06
331-C0014G-16T-2,54.077.22577.225Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.14812.148INTERVAL =54 CM2010-09-23T18:03:15
331-C0014G-16T-CC,26.077.94577.945Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.542TC was corrected because LET was lower than 4.10.542INTERVAL = 26 CM2010-10-22T04:01:10
331-C0014G-17T-1,20.080.40080.400Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.05911.059INTERVAL =20 CM2010-09-23T19:14:55
331-C0014G-17T-2,50.081.11081.110VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.211TC was corrected because LET was lower than 4.11.211INTERVAL = 50 CM2010-10-22T04:02:03
331-C0014G-17T-4,50.083.12583.125VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.22611.226INTERVAL = 50 CM2010-09-23T19:16:59
331-C0014G-18T-2,50.085.51585.515VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.06111.061INTERVAL = 50 CM2010-09-23T19:18:02
331-C0014G-18T-3,50.086.51586.515VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.136TC was corrected because LET was lower than 4.11.136INTERVAL = 50 CM2010-10-22T04:03:16
331-C0014G-18T-4,50.087.52087.520Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.110TC was corrected because LET was lower than 4.11.110INTERVAL = 50 CM2010-10-22T04:04:06
331-C0014G-24T-2,79.0110.490110.490VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.09912.099INTERVAL = 79 CM2010-09-23T19:21:48
331-C0014G-24T-3,20.0110.900110.900VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.73811.738INTERVAL = 20 CM2010-09-23T19:22:17
331-C0014G-24T-CC,28.0113.070113.070Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.71411.714INTERVAL = 28 CM2010-09-23T19:23:00
331-C0014G-24T-CC,40.0113.190113.190Mini HLQ probe, probe body is 50 mm in diameter and 30 mm in height, source length is 45 mm and source diameter 1.2 mm. Use the Mini HLQ for samples too small for the standard HLQ. Measuring range 0.3 - 3 Wm-1K-1.4.50014.500INTERVAL = 40 CM2010-09-23T19:23:31
331-C0014G-25T-1,17.0113.870113.870Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.71011.710INTERVAL = 17 CM2010-09-23T19:24:00