Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Electrical conductivity from IODP Hole 331-C0014G [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776758

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Coverage:
Latitude: 27.790275 * Longitude: 126.900772
Minimum DEPTH, sediment/rock: 0.140 m * Maximum DEPTH, sediment/rock: 114.270 m
Event(s):
331-C0014G * Latitude: 27.790275 * Longitude: 126.900772 * Elevation: -1059.8 m * Recovery: 74.4 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
Formation factorFExpedition 331 ScientistsImpedance analysisSection half, working
Time StampTime StampExpedition 331 ScientistsRegistration
Size:
372 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

F

Time Stamp
331-C0014G-1H-1,14.00.1400.1362.062010-09-26T21:15:54
331-C0014G-1H-1,84.00.8400.8132.182010-09-26T21:15:54
331-C0014G-1H-1,129.01.2901.2492.112010-09-26T21:15:54
331-C0014G-1H-2,11.01.5301.4822.232010-09-24T03:15:24
331-C0014G-1H-2,81.02.2302.1602.322010-09-24T03:15:24
331-C0014G-1H-2,136.02.7802.6922.382010-09-24T03:15:24
331-C0014G-1H-3,19.03.0202.9252.432010-09-24T03:15:25
331-C0014G-1H-3,77.03.6003.4862.222010-09-24T03:15:25
331-C0014G-1H-3,134.04.1704.0382.442010-09-24T03:15:25
331-C0014G-1H-4,35.04.5754.4312.612010-09-24T03:15:25
331-C0014G-1H-4,123.05.4555.2832.482010-09-24T03:15:25
331-C0014G-1H-5,18.05.8205.6362.462010-09-26T21:15:54
331-C0014G-1H-5,75.06.3906.1882.562010-09-26T21:15:54
331-C0014G-1H-6,85.07.9007.6503.122010-09-24T03:15:25
331-C0014G-1H-7,14.08.6008.3283.102010-09-24T03:15:25
331-C0014G-2H-4,54.013.93013.7672.402010-09-24T03:15:26
331-C0014G-2H-4,95.014.34014.1622.392010-09-24T03:15:26
331-C0014G-2H-5,33.015.12514.9201.932010-09-24T03:15:26
331-C0014G-2H-6,85.017.06516.7934.552010-09-24T03:15:26
331-C0014G-2H-6,121.017.42517.1414.672010-09-24T03:15:26
331-C0014G-2H-7,4.017.70017.4064.052010-09-24T03:15:26
331-C0014G-2H-7,100.018.66018.3334.312010-09-24T03:15:26
331-C0014G-2H-CC,24.018.95018.6133.932010-09-24T03:15:26
331-C0014G-3H-1,12.018.82018.8117.862010-09-24T03:15:26
331-C0014G-3H-2,34.019.68019.6032.432010-09-24T03:15:26
331-C0014G-3H-2,117.020.51020.3684.842010-09-24T03:15:26
331-C0014G-3H-3,5.020.80020.6352.482010-09-24T03:15:26
331-C0014G-3H-3,35.021.10020.9113.472010-09-24T03:15:26
331-C0014G-3H-4,22.021.39021.1792.422010-09-24T03:15:26
331-C0014G-3H-4,101.022.18021.9073.752010-09-24T03:15:26
331-C0014G-3H-5,11.022.69022.3764.372010-09-26T21:15:54
331-C0014G-3H-5,101.023.59023.2064.862010-09-26T21:15:54
331-C0014G-3H-5,134.023.92023.5104.642010-09-26T21:15:54
331-C0014G-3H-6,17.024.15023.7225.002010-09-24T03:15:26
331-C0014G-3H-7,9.024.56024.1007.482010-09-26T21:15:54
331-C0014G-3H-7,52.024.99024.49612.672010-09-26T21:15:54
331-C0014G-3H-8,50.025.69525.1457.212010-09-24T03:15:27
331-C0014G-3H-8,117.026.36525.76310.752010-09-24T03:15:27
331-C0014G-3H-9,38.027.03526.3804.002010-09-24T03:15:27
331-C0014G-3H-9,92.027.57526.8784.082010-09-24T03:15:27
331-C0014G-3H-10,19.027.85527.1367.152010-09-24T03:15:26
331-C0014G-3H-10,44.028.10527.3668.942010-09-24T03:15:26
331-C0014G-4H-2,19.029.07529.0753.252010-09-24T03:15:27
331-C0014G-4H-3,17.029.77029.7704.302010-09-24T03:15:27
331-C0014G-4H-4,46.030.33030.3304.232010-09-24T03:15:27
331-C0014G-4H-5,86.031.27031.2704.262010-09-24T03:15:27
331-C0014G-4H-6,59.032.00532.0055.322010-09-24T03:15:27
331-C0014G-4H-7,60.033.02533.0254.412010-09-26T21:15:54
331-C0014G-4H-8,50.033.93033.9305.742010-09-24T03:15:27
331-C0014G-4H-9,83.035.27535.2755.082010-09-24T03:15:28
331-C0014G-4H-10,42.035.87035.8703.592010-09-24T03:15:27
331-C0014G-4H-11,49.036.94536.9453.142010-09-24T03:15:27
331-C0014G-4H-CC,15.037.60537.6055.582010-09-24T03:15:28
331-C0014G-5H-3,45.038.48538.4857.022010-09-24T03:15:28
331-C0014G-5H-5,76.039.71039.7109.632010-09-26T21:15:54
331-C0014G-6H-2,49.047.82547.4825.422010-09-24T03:15:28
331-C0014G-6H-3,79.049.13048.0713.682010-09-24T03:15:28
331-C0014G-6H-4,40.049.75548.3535.812010-09-24T03:15:28
331-C0014G-6H-6,14.051.50549.1422.212010-09-24T03:15:28
331-C0014G-6H-7,86.052.68049.6722.482010-09-24T03:15:28
331-C0014G-6H-CC,62.053.47050.0296.152010-09-26T21:16:00
331-C0014G-9X-2,101.056.61556.61512.222010-09-24T03:15:28
331-C0014G-12H-3,11.065.26065.2609.012010-09-26T21:15:53
331-C0014G-12H-3,84.065.99065.99012.482010-09-26T21:15:53
331-C0014G-13T-1,25.066.95066.95011.432010-09-26T21:15:53
331-C0014G-13T-2,34.068.04068.0405.662010-09-26T21:15:53
331-C0014G-13T-2,71.068.41068.41016.292010-09-26T21:15:53
331-C0014G-13T-3,22.068.92568.9255.802010-09-26T21:15:53
331-C0014G-13T-3,79.069.49569.4957.252010-09-26T21:15:53
331-C0014G-13T-4,7.069.77569.7758.112010-09-26T21:15:53
331-C0014G-13T-4,18.069.88569.8858.492010-09-26T21:15:53
331-C0014G-14T-1,19.071.39071.3907.902010-09-24T03:15:23
331-C0014G-14T-2,74.072.41572.4158.752010-09-26T21:15:53
331-C0014G-14T-3,38.073.07073.0708.222010-09-26T21:15:54
331-C0014G-14T-3,91.073.60073.6008.742010-09-26T21:15:54
331-C0014G-15T-CC,13.076.03575.82915.352010-09-26T21:15:54
331-C0014G-16T-1,31.076.21076.21014.052010-09-24T03:15:24
331-C0014G-16T-2,69.077.37577.3756.482010-09-24T03:15:24
331-C0014G-17T-1,36.080.56080.56010.262010-09-24T03:15:24
331-C0014G-17T-3,38.081.99581.99511.362010-09-24T03:15:24
331-C0014G-17T-4,34.082.96582.9657.412010-09-24T03:15:24
331-C0014G-18T-2,20.085.21585.2154.752010-09-24T03:15:24
331-C0014G-18T-3,83.086.84586.8455.462010-09-26T21:15:54
331-C0014G-18T-4,48.087.50087.5007.982010-09-24T03:15:24
331-C0014G-20T-1,28.093.98093.9807.272010-09-26T21:15:54
331-C0014G-23X-1,25.0104.950104.9509.782010-09-24T03:15:25
331-C0014G-23X-2,18.0105.485105.48513.332010-09-24T03:15:25
331-C0014G-24T-1,19.0109.390109.3907.772010-09-26T21:15:54
331-C0014G-24T-2,72.0110.420110.4206.712010-09-24T03:15:25
331-C0014G-24T-3,40.0111.100111.1006.162010-09-24T03:15:25
331-C0014G-24T-CC,26.0113.050113.05012.352010-09-24T03:15:25
331-C0014G-25T-1,19.0113.890113.8908.522010-09-26T21:15:54
331-C0014G-25T-1,57.0114.270114.2707.752010-09-26T21:15:54