Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0013F [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776376

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0013F, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0013F/
Coverage:
Latitude: 27.790203 * Longitude: 126.897668
Minimum DEPTH, sediment/rock: 0.255 m * Maximum DEPTH, sediment/rock: 8.640 m
Event(s):
331-C0013F * Latitude: 27.790203 * Longitude: 126.897668 * Elevation: -1035.1 m * Recovery: 9.5 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
CommentCommentExpedition 331 ScientistsOf sampling
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Average
NumberNoExpedition 331 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
CommentCommentExpedition 331 ScientistsRun 1 comment
Time StampTime StampExpedition 331 ScientistsRegistration
Size:
80 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Comment
(Of sampling)

k [W/m/K]
(Average, Quick Thermal Conduc...)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

Comment
(Run 1 comment)

Time Stamp
(Registration)
331-C0013F-1H-2,7.00.2550.217Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.83010.830INTERVAL = 7 CM2010-09-25T18:00:58
331-C0013F-1H-3,24.01.4251.213Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.87810.878INTERVAL = 24 CM2010-09-25T18:02:06
331-C0013F-1H-3,74.01.9251.639VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.05111.051INTERVAL = 74 CM2010-09-25T18:25:44
331-C0013F-1H-4,50.02.6852.286Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.99310.993INTERVAL = 50 CM2010-09-25T18:03:18
331-C0013F-1H-5,50.03.6553.112Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.67112.671INTERVAL = 50 CM2010-09-25T18:04:44
331-C0013F-1H-6,30.04.4553.793Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.08011.080INTERVAL = 30 CM2010-09-25T18:05:53
331-C0013F-1H-6,88.05.0354.286VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.96310.963INTERVAL = 88 CM2010-09-25T18:28:40
331-C0013F-1H-8,20.06.3705.423Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.88810.888INTERVAL = 20 CM2010-09-25T18:07:00
331-C0013F-1H-8,66.06.8305.814VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.69510.695INTERVAL = 66 CM2010-09-25T18:29:24
331-C0013F-1H-CC,46.08.6407.355Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.08011.080INTERVAL = 46 CM2010-09-25T18:07:45