Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Moisture and density (MAD) measured on IODP Hole 331-C0014B [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776235

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0014B, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0014B/
Coverage:
Latitude: 27.790218 * Longitude: 126.900747
Minimum DEPTH, sediment/rock: 0.110 m * Maximum DEPTH, sediment/rock: 45.150 m
Event(s):
331-C0014B * Latitude: 27.790218 * Longitude: 126.900747 * Elevation: -1059.0 m * Recovery: 45.01 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designationSample top
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
Sample code/label 2Sample label 2Expedition 331 ScientistsDSDP/ODP/IODP sample designationSample bottom
Depth, bottom/maxDepth botmExpedition 331 Scientists[m CSF-A] Bottom Core depth (below sea floor)
Depth, bottom/maxDepth botmExpedition 331 Scientists[m CSF-B] Bottom Core depth (below sea floor)
Sample volumeSamp volcm3Expedition 331 Scientists
Time StampTime StampExpedition 331 ScientistsOf sampling
Wet massWet mgExpedition 331 ScientistsCalculated
10 Volume, wet sampleVol wet samplecm3Expedition 331 ScientistsCalculated
11 Sample, dry massSamp dmgExpedition 331 ScientistsCalculated
12 Volume, dry sampleVol dry samplecm3Expedition 331 ScientistsIODP Method C (Blum, 1997)
13 Mass, porewaterMass pwgExpedition 331 ScientistsIODP Method C (Blum, 1997)
14 Salt contentSaltgExpedition 331 ScientistsIODP Method C (Blum, 1997)
15 Mass, solidsMass solidsgExpedition 331 ScientistsIODP Method C (Blum, 1997)
16 Water content, wet massWater wm%Expedition 331 ScientistsCalculated
17 Water content, dry massWater dm%Expedition 331 ScientistsCalculated
18 Volume, porewaterVol pwcm3Expedition 331 ScientistsIODP Method C (Blum, 1997)
19 Volume, saltVol saltcm3Expedition 331 ScientistsIODP Method C (Blum, 1997)
20 Volume, solidsVol solidscm3Expedition 331 ScientistsIODP Method C (Blum, 1997)
21 Porosity, fractionalPoros fracExpedition 331 ScientistsIODP Method C (Blum, 1997)
22 Void Ratio descriptionVoid RatioExpedition 331 ScientistsCalculated (Blum, 1997)
23 DensityDensityg/cm3Expedition 331 ScientistsCalculated (Blum, 1997)
24 Density, dry bulkDBDg/cm3Expedition 331 ScientistsCalculated (Blum, 1997)
25 Density, grainDensity graing/cm3Expedition 331 ScientistsCalculated (Blum, 1997)
26 Time StampTime StampExpedition 331 ScientistsOf analysing
Size:
1650 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(Sample top, DSDP/ODP/IODP sam...)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Sample label 2
(Sample bottom, DSDP/ODP/IODP ...)

Depth bot [m]
([m CSF-A] Bottom Core depth (...)

Depth bot [m]
([m CSF-B] Bottom Core depth (...)

Samp vol [cm3]

Time Stamp
(Of sampling)

Wet m [g]
(Calculated)
10 
Vol wet sample [cm3]
(Calculated)
11 
Samp dm [g]
(Calculated)
12 
Vol dry sample [cm3]
(IODP Method C (Blum, 1997))
13 
Mass pw [g]
(IODP Method C (Blum, 1997))
14 
Salt [g]
(IODP Method C (Blum, 1997))
15 
Mass solids [g]
(IODP Method C (Blum, 1997))
16 
Water wm [%]
(Calculated)
17 
Water dm [%]
(Calculated)
18 
Vol pw [cm3]
(IODP Method C (Blum, 1997))
19 
Vol salt [cm3]
(IODP Method C (Blum, 1997))
20 
Vol solids [cm3]
(IODP Method C (Blum, 1997))
21 
Poros frac
(IODP Method C (Blum, 1997))
22 
Void Ratio
(Calculated (Blum, 1997))
23 
Density [g/cm3]
(Calculated (Blum, 1997))
24 
DBD [g/cm3]
(Calculated (Blum, 1997))
25 
Density grain [g/cm3]
(Calculated (Blum, 1997))
26 
Time Stamp
(Of analysing)
331-C0014B-1H-1,11.00.1100.103331-C0014B-1H-1,13.00.1300.121102010-09-16T23:22:336.49884.71852.84741.08303.78380.13242.71500.58221.39373.69510.05961.02340.78313.61061.37730.57542.65292010-09-18T12:17:36
331-C0014B-1H-1,77.00.7700.718331-C0014B-1H-1,79.00.7900.737102010-09-16T23:22:536.44834.32583.27841.16973.28490.11503.16340.50941.03843.20790.05181.11790.74162.86961.49070.73132.82982010-09-18T12:17:36
331-C0014B-1H-2,72.02.1401.996331-C0014B-1H-2,74.02.1602.014102010-09-16T23:23:145.50153.64952.94971.10882.64440.09262.85710.48070.92562.58240.04171.06710.70762.421.50750.78292.67742010-09-18T12:17:36
331-C0014B-1H-2,128.02.7002.518331-C0014B-1H-2,130.02.7202.537102010-09-16T23:23:565.77963.74393.11121.08712.76520.09683.01440.47840.91732.70040.04361.04350.72132.58781.54370.80512.88872010-09-18T12:17:37
331-C0014B-1H-3,34.03.1502.938331-C0014B-1H-3,36.03.1702.956102010-09-16T23:24:136.85534.54273.64651.34783.32520.11643.53010.48510.94203.24730.05241.29540.71482.50681.50910.77712.72512010-09-18T12:17:37
331-C0014B-1H-4,49.04.7204.402331-C0014B-1H-4,51.04.7404.420102010-09-16T23:24:376.87804.39643.85141.38303.13640.10983.74160.45600.83833.06290.04951.33350.69672.29691.56450.85112.80582010-09-18T12:17:37
331-C0014B-1H-5,29.05.9305.530331-C0014B-1H-5,31.05.9505.549102010-09-16T23:25:146.46414.04273.75421.34462.80820.09833.65590.43440.76812.74240.04431.30030.67842.10911.59900.90432.81162010-09-18T12:17:37
331-C0014B-1H-CC,5.06.7606.304331-C0014B-1H-CC,7.06.7806.323102010-09-16T23:25:365.30513.39113.04501.14082.34210.08202.96300.44150.79042.28720.03691.10390.67452.07191.56440.87382.68412010-09-18T12:17:37
331-C0014B-2H-1,77.07.2707.191331-C0014B-2H-1,79.07.2907.209102010-09-17T02:35:594.67593.03932.64641.01872.10310.07362.57280.44980.81742.05380.03320.98550.67572.0841.53850.84652.61072010-09-18T12:17:37
331-C0014B-2H-2,34.08.2108.034331-C0014B-2H-2,36.08.2308.052102010-09-17T02:36:274.17252.60432.39510.83471.84190.06452.33060.44140.79031.79870.02910.80560.69072.23271.60220.89492.89302010-09-18T12:17:37
331-C0014B-2H-2,59.08.4608.258331-C0014B-2H-2,61.08.4808.276102010-09-17T02:36:425.50563.57333.24551.32302.34210.08203.16350.42540.74042.28720.03691.28610.64011.77841.54080.88532.45982010-09-18T12:17:37
331-C0014B-2H-3,131.09.8809.532331-C0014B-2H-3,133.09.9009.550102010-09-17T02:37:032.77022.00911.17050.41641.65770.05801.11250.59841.49011.61880.02610.39030.80574.14761.37880.55372.85042010-09-18T12:17:37
331-C0014B-2H-4,39.010.3709.972331-C0014B-2H-4,41.010.3909.990102010-09-17T02:37:244.99343.41302.57511.00522.50600.08772.48740.50191.00752.44730.03950.96570.71712.53421.46310.72882.57572010-09-18T12:17:37
331-C0014B-2H-5,35.011.08010.609331-C0014B-2H-5,37.011.10010.627102010-09-17T02:37:494.40583.10582.06920.77942.42130.08471.98450.54961.22012.36460.03820.74120.76133.19021.41860.63902.67742010-09-18T12:17:37
331-C0014B-2H-5,92.011.65011.120331-C0014B-2H-5,94.011.67011.138102010-09-17T02:38:144.30532.84162.22100.76642.15990.07562.14540.50171.00682.10930.03410.73230.74232.88041.51510.75502.92972010-09-18T12:17:37
331-C0014B-2H-6,41.012.18011.595331-C0014B-2H-6,43.012.20011.613102010-09-17T02:58:384.82463.16332.49110.84002.41810.08462.40650.50121.00482.36140.03810.80190.74652.94481.52520.76083.00102010-09-18T12:17:37
331-C0014B-2H-6,58.012.35011.748331-C0014B-2H-6,60.012.37011.766102010-09-17T02:38:365.05473.79522.01210.76583.15300.11041.90170.62381.65803.07910.04970.71610.81134.29981.33190.50112.65562010-09-18T12:17:37
331-C0014B-2H-7,8.012.47011.856331-C0014B-2H-7,10.012.49011.87352010-09-17T05:27:164.14423.04081.88280.78922.34340.08201.80080.56551.30132.28850.03690.75230.75263.0421.36290.59222.39372010-09-18T12:17:37
331-C0014B-2H-7,74.013.13012.448331-C0014B-2H-7,76.013.15012.46552010-09-17T05:27:364.23093.00381.92660.70962.38790.08361.84300.56441.29572.33190.03770.67190.77633.47061.40850.61362.74302010-09-18T12:17:38
331-C0014B-2H-8,5.013.41012.699331-C0014B-2H-8,7.013.43012.71752010-09-17T05:27:576.71474.96292.71900.98464.14060.14492.57410.61661.60864.04360.06530.91930.81484.39861.35300.51872.80012010-09-18T12:17:38
331-C0014B-2H-8,38.013.74012.995331-C0014B-2H-8,40.013.76013.01352010-09-17T05:28:157.90635.33124.08861.53013.95620.13853.95010.50041.00153.86350.06241.46770.72472.63231.48300.74092.69142010-09-18T12:17:38
331-C0014B-2H-9,26.014.13513.349331-C0014B-2H-9,28.014.15513.36752010-09-17T05:28:367.79614.69854.80881.72433.09560.10834.70050.39710.65863.02300.04881.67550.64341.80421.65931.00042.80542010-09-18T12:17:38
331-C0014B-2H-9,90.014.77513.923331-C0014B-2H-9,91.014.78513.93252010-09-17T05:28:526.50114.52613.05761.09763.56840.12492.93270.54891.21683.48480.05631.04130.76993.34661.43640.64802.81642010-09-18T12:17:38
331-C0014B-2H-10,11.015.03514.156331-C0014B-2H-10,13.015.05514.17552010-09-17T05:29:147.37264.64914.29831.58823.18580.11154.18680.43210.76093.11110.05021.53800.66922.02281.58580.90062.72222010-09-18T12:17:38
331-C0014B-2H-11,10.015.46514.542331-C0014B-2H-11,12.015.48514.56052010-09-17T05:30:067.39275.19203.34421.16114.19530.14683.19740.56751.31214.09700.06611.09500.78913.74161.42390.61582.92002010-09-18T12:17:38
331-C0014B-2H-11,65.016.01515.036331-C0014B-2H-11,67.016.03515.05452010-09-17T05:30:227.27105.33563.01481.09794.41060.15442.86040.60661.54204.30720.06951.02840.80734.18831.36270.53612.78142010-09-18T12:17:38
331-C0014B-2H-12,20.016.32515.314331-C0014B-2H-12,22.016.34515.33252010-09-17T05:30:446.46654.59032.84320.98283.75470.13142.71180.58061.38463.66670.05920.92360.79883.971.40870.59082.93612010-09-18T12:17:38
331-C0014B-2H-CC,14.016.87515.807331-C0014B-2H-CC,16.016.89515.82552010-09-17T05:31:005.03613.60202.06750.64633.07630.10771.95980.61081.56973.00420.04850.59780.83405.02541.39810.54413.27842010-09-18T12:17:38
331-C0014B-3H-1,23.016.23016.190331-C0014B-3H-1,25.016.25016.20652010-09-17T12:28:445.73354.17682.39750.85533.45700.12102.27650.60291.51863.37600.05450.80080.80834.21581.37270.54502.84282010-09-19T06:15:02
331-C0014B-3H-2,35.017.19016.983331-C0014B-3H-2,37.017.21017.00052010-09-17T12:29:027.42965.24293.35531.18644.22210.14783.20750.56831.31634.12310.06661.11980.78643.6821.41710.61182.86442010-09-19T06:15:02
331-C0014B-3H-3,50.018.11017.743331-C0014B-3H-3,52.018.13017.76052010-09-17T12:29:235.76334.29922.33400.88483.55370.12442.20960.61661.60833.47040.05600.82880.80724.18731.34060.51402.66602010-09-19T06:15:02
331-C0014B-3H-4,8.018.70018.230331-C0014B-3H-4,10.018.72018.24752010-09-17T12:29:525.41703.75542.49680.84793.02610.10592.39090.55861.26572.95520.04770.80020.78693.69311.44250.63672.98792010-09-19T06:15:02
331-C0014B-3H-5,35.020.20519.474331-C0014B-3H-5,37.020.22519.49052010-09-17T12:30:205.79464.43412.13310.78853.79430.13282.00030.65481.89693.70540.05980.72870.83575.08491.30680.45112.74502010-09-19T06:15:03
331-C0014B-3H-5,114.020.99520.126331-C0014B-3H-5,116.021.01520.14352010-09-17T12:30:374.48863.34811.58110.45323.01300.10551.47560.67132.04192.94240.04750.40570.87887.25261.34060.44073.63722010-09-19T06:15:03
331-C0014B-3H-6,51.021.75520.754331-C0014B-3H-6,53.021.77520.77152010-09-17T12:30:544.06502.79901.92520.66862.21740.07761.84760.54551.20022.16540.03500.63360.77363.41761.45230.66012.91602010-09-19T06:15:03
331-C0014B-3H-7,9.021.96520.928331-C0014B-3H-7,11.021.98520.94452010-09-17T12:31:296.02744.55282.27950.82123.88380.13592.14360.64441.81183.79280.06120.76000.83314.99051.32390.47082.82052010-09-19T06:15:03
331-C0014B-3H-7,44.022.31521.217331-C0014B-3H-7,46.022.33521.23352010-09-17T12:31:427.99014.83125.03861.89263.05850.10704.93160.38280.62022.98680.04821.84440.61821.61941.65391.02082.67382010-09-19T06:15:03
331-C0014B-3H-8,9.023.15521.911331-C0014B-3H-8,11.023.17521.92752010-09-17T12:32:046.23494.66792.44990.89933.92230.13732.31260.62911.69613.83040.06180.83750.82064.57361.33570.49542.76132010-09-19T06:15:03
331-C0014B-3H-9,4.024.32522.877331-C0014B-3H-9,6.024.34522.89452010-09-17T12:32:227.63784.99304.05901.42983.70860.12983.92920.48560.94393.62170.05851.37130.72542.64111.52970.78692.86532010-09-19T06:15:03
331-C0014B-3H-10,19.025.25023.641331-C0014B-3H-10,21.025.27023.65852010-09-17T12:32:396.81214.77043.09771.07223.84910.13472.96300.56501.29913.75890.06071.01150.78803.71621.42800.62112.92932010-09-19T06:15:03
331-C0014B-3H-11,91.026.53524.703331-C0014B-3H-11,93.026.55524.71952010-09-17T12:33:026.72954.57603.20801.06983.64920.12773.08030.54231.18473.56370.05751.01230.77883.52041.47060.67313.04292010-09-19T06:15:03
331-C0014B-3H-12,27.027.07525.149331-C0014B-3H-12,29.027.09525.16552010-09-17T12:33:185.69873.88932.67980.88353.12840.10952.57030.54901.21713.05510.04930.83420.78553.66231.46520.66093.08122010-09-19T06:15:03
331-C0014B-3H-CC,19.027.35025.376331-C0014B-3H-CC,21.027.37025.39352010-09-17T12:33:346.61214.33883.35211.09303.37820.11823.23390.51091.04463.29900.05321.03980.76033.17271.52390.74533.11012010-09-19T06:15:03
331-C0014B-4H-1,19.025.69025.677331-C0014B-4H-1,21.025.71025.696102010-09-17T18:53:385.34633.36632.91820.94882.51620.08812.83010.47060.88912.45720.03970.90910.72992.70291.58820.84073.11312010-09-19T06:15:03
331-C0014B-4H-1,47.025.97025.938331-C0014B-4H-1,49.025.99025.957102010-09-17T18:54:035.33783.26223.10871.04282.30990.08083.02790.43270.76292.25580.03641.00640.69152.24151.63630.92823.00862010-09-19T06:15:03
331-C0014B-4H-2,79.026.85526.763331-C0014B-4H-2,81.026.87526.782102010-09-17T18:54:254.25882.78402.30930.84292.02020.07072.23860.47440.90241.97290.03180.81110.70872.43241.52970.80412.76002010-09-19T06:15:03
331-C0014B-4H-3,119.028.66028.446331-C0014B-4H-3,121.028.68028.465102010-09-17T18:54:594.07442.53712.41660.88661.71790.06012.35650.42160.72901.67760.02710.85950.66121.95181.60590.92882.74172010-09-19T06:15:03
331-C0014B-4H-4,73.029.61029.332331-C0014B-4H-4,75.029.63029.350102010-09-17T18:55:184.23182.57592.49910.85081.79550.06282.43630.42430.73701.75340.02830.82250.68072.13181.64280.94582.96212010-09-19T06:15:03
331-C0014B-4H-5,15.030.25529.933331-C0014B-4H-5,17.030.27529.952102010-09-17T18:55:405.54923.56063.01051.03302.63080.09212.91840.47410.90152.56910.04150.99150.72152.59111.55850.81962.94342010-09-19T06:15:03
331-C0014B-4H-6,54.031.08030.702331-C0014B-4H-6,56.031.10030.721102010-09-17T18:56:014.88303.16672.69530.98852.26700.07932.61600.46430.86662.21390.03570.95280.69912.32361.54200.82612.74562010-09-19T06:15:04
331-C0014B-4H-7,102.032.95032.445331-C0014B-4H-7,104.032.97032.464102010-09-17T20:30:023.76172.36192.05230.65991.77140.06201.99030.47090.89001.72990.02790.63200.73242.73721.59270.84273.14922010-09-19T06:15:04
331-C0014B-4H-8,63.033.97033.396331-C0014B-4H-8,65.033.99033.415102010-09-17T20:30:264.98253.50082.18160.71212.90250.10162.08000.58251.39542.83450.04580.66630.80974.25411.42320.59413.12172010-09-19T06:15:04
331-C0014B-4H-9,16.034.91034.273331-C0014B-4H-9,18.034.93034.292102010-09-17T20:30:455.65393.85032.75130.96033.00790.10532.64600.53201.13682.93740.04740.91290.76293.21771.46840.68722.89852010-09-19T06:15:04
331-C0014B-4H-9,49.035.24034.581331-C0014B-4H-9,51.035.26034.599102010-09-17T20:31:014.49603.18452.05020.74942.53450.08871.96150.56371.29212.47510.04000.70940.77723.4891.41180.61602.76502010-09-19T06:15:04
331-C0014B-5H-1,7.035.07035.065331-C0014B-5H-1,9.035.09035.083102010-09-17T23:37:494.21603.06361.70370.56222.60340.09111.61260.61751.61442.54240.04100.52120.82994.8781.37620.52643.09402010-09-19T06:15:04
331-C0014B-5H-2,29.035.44535.411331-C0014B-5H-2,31.035.46535.42952010-09-19T05:35:306.82154.71033.26391.16823.68660.12903.13490.54041.17603.60020.05811.11010.76433.24311.44820.66552.82402010-09-20T11:42:36
331-C0014B-5H-3,64.036.17036.080331-C0014B-5H-3,66.036.19036.09952010-09-19T05:35:537.08055.01383.19561.14594.02580.14093.05470.56861.31793.93140.06351.08240.78413.63211.41220.60932.82222010-09-20T11:42:36
331-C0014B-5H-4,79.037.28037.105331-C0014B-5H-4,81.037.30037.12352010-09-19T05:36:096.18164.60282.49200.92933.82340.13382.35820.61851.62133.73380.06030.86900.81124.29671.34300.51232.71372010-09-20T11:42:36
331-C0014B-5H-5,64.038.52538.254331-C0014B-5H-5,66.038.54538.27352010-09-19T05:36:277.00854.85913.35351.22003.78760.13263.22090.54041.17593.69880.05971.16030.76123.18781.44230.66292.77592010-09-20T11:42:36
331-C0014B-5H-6,29.039.56039.210331-C0014B-5H-6,31.039.58039.22852010-09-19T05:36:497.41615.28953.42671.31754.13410.14473.28200.55741.25964.03720.06521.25230.76323.22381.40200.62052.62082010-09-20T11:42:36
331-C0014B-5H-11,59.040.29039.884331-C0014B-5H-11,61.040.31039.902102010-09-17T23:38:226.44834.76352.53140.86364.05900.14212.38930.62951.69883.96390.06400.79960.83214.95741.35370.50162.98812010-09-19T06:15:04
331-C0014B-5H-12,29.040.87540.424331-C0014B-5H-12,31.040.89540.442102010-09-17T23:38:413.93822.72911.68400.48462.33600.08181.60220.59321.45802.28130.03680.44780.83595.09451.44300.58713.57792010-09-19T06:15:04
331-C0014B-5H-13,84.042.32541.763331-C0014B-5H-13,86.042.34541.781102010-09-17T23:38:593.81552.34532.28790.82441.58300.05542.23250.41490.70911.54590.02500.79940.65911.93381.62690.95192.79272010-09-19T06:15:04
331-C0014B-5H-14,83.043.41542.769331-C0014B-5H-14,85.043.43542.787102010-09-17T23:39:285.19012.83003.71231.35861.53140.05363.65870.29510.41861.49550.02411.33450.52841.12061.83401.29282.74162010-09-19T06:15:04
331-C0014B-5H-15,49.044.35043.632331-C0014B-5H-15,51.044.37043.651102010-09-17T23:39:495.59793.30533.52891.24532.14400.07503.45390.38300.62072.09380.03381.21150.63351.72831.69361.04502.85092010-09-19T06:15:04
331-C0014B-5H-CC,9.045.15044.371331-C0014B-5H-CC,11.045.17044.389102010-09-17T23:40:124.36402.90932.20940.76412.23270.07812.13130.51161.04762.18040.03520.72890.74952.99141.50000.73262.92402010-09-19T06:15:04