Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2012): Thermal conductivity of IODP Hole 331-C0013E [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.776204

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Takai, Ken; Mottl, Michael J; Nielsen, Simon Harder Holm; Expedition 331 Scientists (2010): Integrated Ocean Drilling Program Expedition 331 Preliminary Report. Deep Hot Biosphere. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 331, https://doi.org/10.2204/iodp.pr.331.2010
Other version:
IODP Hole 331-C0013E, snapshot taken on 2011-10-03, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/331/C0013E/
Coverage:
Latitude: 27.790262 * Longitude: 126.897577
Minimum DEPTH, sediment/rock: 0.090 m * Maximum DEPTH, sediment/rock: 28.075 m
Event(s):
331-C0013E * Latitude: 27.790262 * Longitude: 126.897577 * Elevation: -1034.0 m * Recovery: 11.59 m * Campaign: Exp331 (Deep Hot Biosphere) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 331 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 331 Scientists[m CSF-B] Top Core depth (below sea floor)
CommentCommentExpedition 331 ScientistsOf sampling
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Average
CommentCommentExpedition 331 ScientistsHorizon comment
NumberNoExpedition 331 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 331 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
CommentCommentExpedition 331 ScientistsRun 1 comment
10 Time StampTime StampExpedition 331 ScientistsRegistration
Size:
149 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Comment
(Of sampling)

k [W/m/K]
(Average, Quick Thermal Conduc...)

Comment
(Horizon comment)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

Comment
(Run 1 comment)
10 
Time Stamp
(Registration)
331-C0013E-1H-1,9.00.0900.090VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.79612.796Interval = 9 CM2010-09-12T19:48:57
331-C0013E-1H-2,70.00.8600.860VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.35712.357Interval = 70 CM2010-09-12T19:50:54
331-C0013E-1H-2,120.01.3601.360VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.129TC was corrected because LET was lower than 4.12.129Interval = 120CM2010-10-22T01:04:12
331-C0013E-1H-3,19.01.7601.760VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.793TC was corrected because LET was lower than 4.12.793Interval = 19 CM2010-10-22T01:04:57
331-C0013E-1H-4,7.02.0752.075VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.2.418TC was corrected because LET was lower than 4.12.418Interval = 7 CM2010-10-22T01:06:10
331-C0013E-1H-4,60.02.6052.605VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.61611.616Interval = 60 CM2010-09-12T19:53:17
331-C0013E-1H-4,120.03.2053.205VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.3.76913.769Interval = 120 CM2010-09-12T19:52:41
331-C0013E-1H-5,21.03.6003.600VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.3.33513.335Interval = 21 CM2010-09-12T19:54:52
331-C0013E-1H-5,70.04.0904.090VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.84111.841Interval = 70 CM2010-09-12T19:55:26
331-C0013E-1H-5,110.04.4904.490VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.41311.413Interval = 110 CM2010-09-12T19:54:23
331-C0013E-1H-6,55.05.2555.255VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.0.98510.985Interval = 55 CM, Heating power = 22010-09-12T19:56:52
331-C0013E-1H-6,105.05.7555.755VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.87811.878Interval = 105 CM2010-09-12T19:55:58
331-C0013E-2H-1,71.09.2109.198VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.6.27516.275Interval = 71.5 CM2010-09-12T19:57:51
331-C0013E-2H-CC,14.09.6359.616VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.86911.869Interval = 14 CM2010-09-12T19:58:24
331-C0013E-5H-1,57.016.57016.570VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.62011.620Interval = 57 CM2010-09-12T20:03:01
331-C0013E-5H-1,122.017.22017.220VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.1.428TC was corrected because LET was lower than 4.11.428Interval = 122 CM2010-10-22T01:09:22
331-C0013E-6X-CC,9.023.09023.090VLQ laboratory probe, source length is 60 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.3.09613.096Interval = 9 CM2010-10-02T19:52:02
331-C0013E-7L-CC,23.028.07528.075Standard HLQ laboratory probe, probe body is 88 mm in diameter and 30 mm in height, source length is 70 mm and source diameter 2 mm. Measuring range 0.3 - 10 Wm-1K-1.3.211TC was corrected because LET was lower than 4.13.211INTERVAL = 23 CM2010-10-22T01:13:12