Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Schlosser, Christian (2012): Trace metal concentration from water samples during Maria S. Merian cruise MSM10/1 [dataset]. IFM-GEOMAR Leibniz-Institute of Marine Sciences, Kiel University, PANGAEA, https://doi.org/10.1594/PANGAEA.775062

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2012-01-31DOI registered: 2016-05-10

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Related to:
Visbeck, Martin (2008): Short Cruise Report MSM10/1, Ponta Delgada-Mindelo, 31.12.2008-06.12.2008. Leibniz Institute of Marine Sciences, IFM-GEOMAR at the University of Kiel, Germany, 15 pp, https://doi.org/10.3289/scr_msm10_1
Funding:
German Research Foundation (DFG), grant/award no. 27542298: Climate - Biogeochemistry Interactions in the Tropical Ocean
Coverage:
Median Latitude: 9.505466 * Median Longitude: -23.450666 * South-bound Latitude: 6.000167 * West-bound Longitude: -27.500000 * North-bound Latitude: 13.500000 * East-bound Longitude: -21.003167
Date/Time Start: 2008-11-06T05:07:00 * Date/Time End: 2008-11-24T20:56:00
Minimum DEPTH, water: 50 m * Maximum DEPTH, water: 800 m
Event(s):
MSM10/1-GO-FLO4  * Latitude: 13.500000 * Longitude: -27.500000 * Date/Time: 2008-11-06T05:07:00 * Campaign: MSM10/1 * Basis: Maria S. Merian * Method/Device: Go-Flo bottles (GOFLO)
MSM10/1-GO-FLO21  * Latitude: 7.500500 * Longitude: -24.999833 * Date/Time: 2008-11-08T21:48:00 * Campaign: MSM10/1 * Basis: Maria S. Merian * Method/Device: Go-Flo bottles (GOFLO)
MSM10/1-GO-FLO72  * Latitude: 6.000167 * Longitude: -22.250000 * Date/Time: 2008-11-14T15:50:00 * Campaign: MSM10/1 * Basis: Maria S. Merian * Method/Device: Go-Flo bottles (GOFLO)
Comment:
Sampling:Subsurface seawater samples were collected with 4 GO-FLO bottles that were deployed on the kevlar cable of the Maria S. Merian.Sample treatment at sea:Samples were filtered through a 0.2 µm Sartorius cartridge filter into acid cleaned 1 L LDPE bottles. After filtration, trace metal samples were acidified with Q-HCl (3 ml into 1 ml SW), below pH 2. Filtered samples for ligand measurements (FeL, ZnL, CdL) were filled in 0.5 L HDPE bottles and frozen prior analysis on board.All ligand measurements were performed at sea.All work was performed under clean air conditions in a clean container (University of Bremen).Measurement:Trace metal concentrations were measured at Kiel by GF-AAS and a method adopted from Grasshoff et al. (1999). Iron ligand concentrations were measured by voltammetry (CLE-ACSV) and a method adopted from Croot and Johansson (2000).Quality Flag:WOCE converted to internal format, see hdl:10013/epic.31518.d001.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Event labelEvent
Date/Time of eventDate/Time
Latitude of eventLatitude
Longitude of eventLongitude
DEPTH, waterDepth watermGeocode
Sample code/labelSample labelSchlosser, Christian
Bottle numberBottleSchlosser, Christian
CadmiumCdnmol/lSchlosser, Christian
CobaltConmol/lSchlosser, Christian
10 CopperCunmol/lSchlosser, Christian
11 IronFenmol/lSchlosser, Christian
12 NickelNinmol/lSchlosser, Christian
13 LeadPbnmol/lSchlosser, Christian
14 ZincZnnmol/lSchlosser, Christian
15 Iron-binding ligand, dissolvedFeL dissnmol/lSchlosser, Christian
16 Iron, dissolved, conditional complex stabilityFe LogK´ dissSchlosser, Christian
Size:
436 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Event

Date/Time

Latitude

Longitude

Depth water [m]

Sample label

Bottle

Cd [nmol/l]

Co [nmol/l]
10 
Cu [nmol/l]
11 
Fe [nmol/l]
12 
Ni [nmol/l]
13 
Pb [nmol/l]
14 
Zn [nmol/l]
15 
FeL diss [nmol/l]
16 
Fe LogK´ diss
MSM10/1-GO-FLO4 2008-11-06T05:0713.5000-27.50005010271240.0070.0240.5651.1501.7200.208?5.320?2.161?11.82
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.500010010271360.0930.0420.7080.6732.7800.0690.8410.745
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.5000150102714120.2100.0580.7301.2903.6000.0230.7691.92811.68
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.500020010271580.0200.031?6.1501.1101.9100.166?4.420?0.963
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.500030010271640.2140.0460.5520.5002.3700.0622.600?0.742?13.27
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.500040010271760.2980.0490.8101.2003.4800.0491.6701.641?12.54
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.5000600102718120.3970.0490.8801.2304.2100.0291.3901.304?13.56
MSM10/1-GO-FLO42008-11-06T05:0713.5000-27.500080010271980.4470.0531.0801.3204.8900.0372.8601.456?13.50
MSM10/1-GO-FLO21 2008-11-08T21:487.5005-24.99985010278140.0060.0100.4590.4031.6000.1201.2701.402?12.33
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.999810010278260.0650.0270.6800.6682.4400.0590.9600.971?13.07
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.9998150102783120.1450.0480.5931.1402.6800.0251.0201.805?11.80
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.999820010278480.1610.0420.6401.1303.0300.0300.8301.878?12.19
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.999835010278540.2860.0480.6471.1503.3700.0391.2001.993?12.35
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.999850010278660.3830.0590.7851.3904.0700.0161.2401.768?13.01
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.9998600102787120.3840.0510.7411.2303.4100.0241.4101.316
MSM10/1-GO-FLO212008-11-08T21:487.5005-24.999880010278880.4490.0390.7770.9883.8500.0191.4300.794
MSM10/1-GO-FLO72 2008-11-14T15:506.0002-22.25005010278940.0020.0100.5351.1001.6900.0990.5311.80812.34
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.250010010279060.0070.0120.5261.1302.3700.0150.9472.07412.70
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.2500150102791120.1230.0320.3300.7322.1100.0190.5021.75712.00
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.250020010279280.1410.0250.3130.6281.8900.0090.291?0.35412.72
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.250026010279340.2310.1000.521?3.5303.4600.0381.770?3.938?13.09
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.250040010279460.3110.0410.7551.2202.8800.0140.9681.70212.95
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.2500600102795120.4730.0460.8641.6005.0600.0191.3301.92412.54
MSM10/1-GO-FLO722008-11-14T15:506.0002-22.250080010279680.4020.0310.8530.9273.7100.0201.8201.18912.78
MSM10/1-GO-FLO107 2008-11-17T15:119.4993-21.50035010517140.0290.0270.6670.7162.9000.056?2.2302.43411.41
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.500310010517260.1970.0390.5551.1703.4200.0290.5901.80512.57
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.5003150105173120.2140.0370.7031.4803.7700.0220.8202.43612.73
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.500320010517480.2370.0460.4611.1003.0500.0230.8891.46413.16
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.500330010517540.3060.0480.7681.4904.0600.0292.1901.81513.18
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.500341010517660.3640.0610.8211.5504.2600.0361.4501.88813.02
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.5003600105177120.4780.0370.7191.6304.7900.0241.6802.17713.35
MSM10/1-GO-FLO1072008-11-17T15:119.4993-21.500380010517880.5070.0480.8471.4105.2500.0211.9401.70413.21
MSM10/1-GO-FLO155 2008-11-24T20:5611.0273-21.00325010517940.0050.0220.4590.6322.1300.0580.9681.35313.06
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.003210010518060.1060.0440.5320.5941.8100.0140.5461.31812.42
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.0032150105181120.1940.0370.5931.2603.4400.0290.6901.48913.56
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.003220010518280.1650.0410.6920.6451.7900.0210.7831.14912.20
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.003230010518340.2050.0360.4190.7322.3200.0490.8780.91512.79
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.003240010518460.3620.0590.6441.1803.8800.0300.6811.90612.43
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.0032600105185120.4210.0510.6531.2203.7000.0201.0801.82712.42
MSM10/1-GO-FLO1552008-11-24T20:5611.0273-21.003280010518680.4960.0460.8701.4605.2500.0091.9702.25112.48