Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Other version:
IODP Hole 316-C0007C, snapshot taken on 2010-11-09, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/316/C0007C/
Coverage:
Latitude: 33.020543 * Longitude: 136.799142
Date/Time Start: 2008-01-14T00:00:00 * Date/Time End: 2008-01-14T00:00:00
Minimum DEPTH, sediment/rock: 13.190 m * Maximum DEPTH, sediment/rock: 130.380 m
Event(s):
316-C0007C * Latitude: 33.020543 * Longitude: 136.799142 * Date/Time: 2008-01-14T00:00:00 * Elevation: -4081.0 m * Recovery: 59.31 m * Campaign: Exp316 (NanTroSEIZE Stage 1: Shallow Megaslay and Frontal Thrusts) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 18 cores; 163.5 m cored; 36.29 % recovery; 176.1 m drilled; 176.09 m penetrated
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor). Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 314/315/316 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 314/315/316 Scientists[m CSF-B] Top Core depth (below sea floor)
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Average
NumberNoExpedition 314/315/316 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 2
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 3
CommentCommentExpedition 314/315/316 Scientists
10 Time StampTime StampExpedition 314/315/316 ScientistsRegistration
Size:
280 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

k [W/m/K]
(Average, Quick Thermal Conduc...)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

k [W/m/K]
(Run 2, Quick Thermal Conducti...)

k [W/m/K]
(Run 3, Quick Thermal Conducti...)

Comment
10 
Time Stamp
(Registration)
316-C0007C-1H-1,55.013.19013.1681.23931.2481.2291.2402008-01-15T23:57:17
316-C0007C-1H-4,50.015.97515.8421.35431.3551.3531.3562008-01-15T23:58:56
316-C0007C-1H-6,40.017.52017.3261.36721.3641.3712008-01-16T00:00:11
316-C0007C-1H-7,30.018.61518.3771.34021.3351.3452008-01-16T00:01:48
316-C0007C-1H-8,25.019.97019.6781.44521.4431.4482008-01-16T00:06:11
316-C0007C-3H-1,40.030.49030.4721.42621.4251.4282008-01-16T00:08:03
316-C0007C-3H-3,50.032.22532.1261.30731.3061.3081.3082008-01-16T00:09:36
316-C0007C-3H-5,50.033.64033.4761.32621.3191.3332008-01-16T00:10:29
316-C0007C-3H-9,110.039.66039.2181.32421.3301.319sections 6-8 only half full, this section 3/4 full2008-01-16T00:11:40
316-C0007C-6X-1,40.052.99052.9901.00831.0400.9841.0002008-01-16T22:42:22
316-C0007C-6X-2,30.054.29554.2951.47131.4651.4741.4742008-01-16T22:43:54
316-C0007C-6X-4,65.056.04556.0451.35431.3411.3601.3612008-01-16T22:45:29
316-C0007C-7X-1,50.062.59062.5901.39431.3951.3891.4002008-01-17T00:01:16
316-C0007C-7X-2,50.063.99563.9951.32531.3261.3301.3212008-01-17T00:02:25
316-C0007C-7X-4,50.065.40565.4051.33131.3301.3291.3352008-01-17T00:03:47
316-C0007C-7X-5,50.066.81566.8151.42321.5551.2922008-01-17T00:05:05
316-C0007C-7X-5,115.067.46567.4651.43731.4391.4461.4282008-01-17T00:06:14
316-C0007C-8X-1,50.072.09072.0901.19831.1901.1811.2242008-01-18T15:39:36
316-C0007C-8X-2,60.073.61073.6101.34731.3511.3481.3442008-01-17T00:23:23
316-C0007C-8X-4,60.075.30575.3051.28531.3071.2751.2742008-01-17T00:24:40
316-C0007C-8X-6,20.077.44577.4451.11131.1191.0961.1202008-01-17T00:26:02
316-C0007C-9X-1,60.081.69081.6691.01430.9931.0051.0462008-01-17T00:46:12
316-C0007C-9X-3,40.084.30084.1861.18831.2011.1841.1802008-01-18T15:40:51
316-C0007C-9X-6,30.087.03586.8241.25531.2511.2761.2402008-01-18T15:41:34
316-C0007C-9X-8,50.090.05089.7321.40131.4001.4101.3942008-01-17T00:49:06
316-C0007C-10X-1,85.091.44091.4401.22431.2221.2271.2232008-01-17T02:14:02
316-C0007C-10X-3,20.092.42092.4201.21421.2281.2002008-01-17T02:15:22
316-C0007C-10X-3,30.092.52092.5201.41031.4041.4141.4142008-01-17T02:19:58
316-C0007C-10X-4,30.093.71093.7101.25831.2691.2581.2482008-01-17T02:22:33
316-C0007C-11X-1,60.0100.690100.6901.39531.4071.3761.4042008-01-17T02:34:21
316-C0007C-11X-2,60.0102.110102.1101.24231.2391.2121.2752008-01-17T02:35:53
316-C0007C-11X-2,100.0102.510102.5101.16431.2141.0961.1822008-01-17T02:37:01
316-C0007C-11X-4,40.0103.335103.3351.39231.3941.3961.3872008-01-17T02:39:06
316-C0007C-12X-1,34.0109.930109.9301.68321.6751.6922008-01-17T02:46:44
316-C0007C-14X-1,80.0129.390129.3901.37131.3521.3441.4192008-01-18T00:47:04
316-C0007C-14X-CC,15.0130.380130.3801.43431.4431.4301.4292008-01-18T00:47:46