Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Other version:
IODP Hole 315-C0001H, snapshot taken on 2011-04-14, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Coverage:
Latitude: 33.238722 * Longitude: 136.711400
Minimum DEPTH, sediment/rock: 241.970 m * Maximum DEPTH, sediment/rock: 439.305 m
Event(s):
315-C0001H * Latitude: 33.238722 * Longitude: 136.711400 * Elevation: -2197.0 m * Campaign: Exp315 (NanTroSEIZE Stage 1: Megasplay Riser Pilot) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 26 RCB cores; 228.6 m cored; 55.2 % recovered; 590.5 m drilled; Hole caving
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 314/315/316 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 314/315/316 Scientists[m CSF-B] Top Core depth (below sea floor)
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsThermal conductivity after M. Kinoshita
Time StampTime StampExpedition 314/315/316 Scientists
Size:
136 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

k [W/m/K]

Time Stamp
315-C0001H-2R-2,106.0241.970241.9701.2712008-06-06T05:32:38
315-C0001H-3R-1,101.5250.015250.0151.0992008-06-06T05:32:38
315-C0001H-3R-3,86.0252.675252.6751.1782008-06-06T05:32:38
315-C0001H-4R-1,125.0259.750259.7501.2712008-06-06T05:32:38
315-C0001H-4R-3,20.5261.530261.5301.2242008-06-06T05:32:38
315-C0001H-4R-6,88.0265.055265.0551.2212008-06-06T05:32:38
315-C0001H-5R-4,80.0271.650271.6501.2192008-06-06T05:32:38
315-C0001H-7R-1,30.0287.300287.3001.2752008-06-06T05:32:38
315-C0001H-7R-2,40.0288.810288.8101.1022008-06-06T05:32:38
315-C0001H-7R-5,126.5292.540292.5401.1812008-06-06T05:32:38
315-C0001H-7R-6,124.0293.930293.9301.2752008-06-06T05:32:38
315-C0001H-10R-3,34.5315.205315.2051.3022008-06-06T05:31:45
315-C0001H-10R-6,133.5319.050319.0501.2032008-06-06T05:32:30
315-C0001H-11R-2,107.5323.995323.9951.2362008-06-06T05:32:37
315-C0001H-11R-6,103.0328.310328.3101.2352008-06-06T05:32:37
315-C0001H-12R-2,21.3332.623332.6231.2002008-06-06T05:32:37
315-C0001H-12R-3,19.5334.020334.0201.2392008-06-06T05:32:37
315-C0001H-12R-5,110.5336.370336.3701.2372008-06-06T05:32:37
315-C0001H-12R-6,46.5337.150337.1501.2792008-06-06T05:32:37
315-C0001H-13R-2,65.5342.560342.5601.2552008-06-06T05:32:37
315-C0001H-13R-3,37.5343.700343.7001.2502008-06-06T05:32:37
315-C0001H-13R-6,15.0346.305346.3051.2162008-06-06T05:32:37
315-C0001H-13R-7,102.0348.585348.5851.2742008-06-06T05:32:37
315-C0001H-14R-1,37.5350.375350.3751.1632008-06-06T05:32:37
315-C0001H-14R-3,87.0353.695353.6951.2702008-06-06T05:32:37
315-C0001H-14R-5,40.0354.660354.6601.2892008-06-06T05:32:37
315-C0001H-14R-6,46.3356.123356.1231.2842008-06-06T05:32:37
315-C0001H-15R-5,80.0364.640364.6401.3152008-06-06T05:32:37
315-C0001H-16R-5,119.0374.445374.4451.2302008-06-06T05:32:38
315-C0001H-21R-1,127.5413.775413.7751.3202008-06-06T05:32:38
315-C0001H-21R-4,92.0416.270416.2701.3592008-06-06T05:32:38
315-C0001H-22R-1,21.0419.710419.7101.2492008-06-06T05:32:38
315-C0001H-22R-2,92.0421.840421.8401.2732008-06-06T05:32:38
315-C0001H-24R-1,80.5439.305439.3051.3142008-06-06T05:32:38