Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2012): Moisture and density (MAD) measured on IODP Hole 316-C0007B [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.773976

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2012-01-13DOI registered: 2012-07-05

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Other version:
IODP Hole 316-C0007B, snapshot taken on 2010-11-09, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/316/C0007B/
Coverage:
Latitude: 33.020543 * Longitude: 136.799142
Date/Time Start: 2008-01-14T00:00:00 * Date/Time End: 2008-01-14T00:00:00
Minimum DEPTH, sediment/rock: 3.340 m * Maximum DEPTH, sediment/rock: 12.580 m
Event(s):
316-C0007B * Latitude: 33.020543 * Longitude: 136.799142 * Date/Time: 2008-01-14T00:00:00 * Elevation: -4081.0 m * Recovery: 10.03 m * Campaign: Exp316 (NanTroSEIZE Stage 1: Shallow Megaslay and Frontal Thrusts) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 1 cores; 9.5 m cored; 105.58 % recovery; 12.6 m drilled; 12.64 m penetrated
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 314/315/316 ScientistsDSDP/ODP/IODP sample designationSample top
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 314/315/316 Scientists[m CSF-B] Top Core depth (below sea floor)
Sample code/label 2Sample label 2Expedition 314/315/316 ScientistsDSDP/ODP/IODP sample designationSample bottom
Depth, bottom/maxDepth botmExpedition 314/315/316 Scientists[m CSF-A] Bottom Core depth (below sea floor)
Depth, bottom/maxDepth botmExpedition 314/315/316 Scientists[m CSF-B] Bottom Core depth (below sea floor)
Sample volumeSamp volcm3Expedition 314/315/316 Scientists
Time StampTime StampExpedition 314/315/316 ScientistsOf sampling
Wet massWet mgExpedition 314/315/316 ScientistsCalculated
10 Volume, wet sampleVol wet samplecm3Expedition 314/315/316 ScientistsCalculated
11 Sample, dry massSamp dmgExpedition 314/315/316 ScientistsCalculated
12 Volume, dry sampleVol dry samplecm3Expedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
13 Mass, porewaterMass pwgExpedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
14 Salt contentSaltgExpedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
15 Mass, solidsMass solidsgExpedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
16 Water content, wet massWater wm%Expedition 314/315/316 ScientistsCalculated
17 Water content, dry massWater dm%Expedition 314/315/316 ScientistsCalculated
18 Volume, porewaterVol pwcm3Expedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
19 Volume, saltVol saltcm3Expedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
20 Volume, solidsVol solidscm3Expedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
21 Porosity, fractionalPoros fracExpedition 314/315/316 ScientistsIODP Method C (Blum, 1997)
22 Void Ratio descriptionVoid RatioExpedition 314/315/316 ScientistsCalculated (Blum, 1997)
23 DensityDensityg/cm3Expedition 314/315/316 ScientistsCalculated (Blum, 1997)
24 Density, dry bulkDBDg/cm3Expedition 314/315/316 ScientistsCalculated (Blum, 1997)
25 Density, grainDensity graing/cm3Expedition 314/315/316 ScientistsCalculated (Blum, 1997)
26 Time StampTime StampExpedition 314/315/316 ScientistsOf analysing
Size:
375 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(Sample top, DSDP/ODP/IODP sam...)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Sample label 2
(Sample bottom, DSDP/ODP/IODP ...)

Depth bot [m]
([m CSF-A] Bottom Core depth (...)

Depth bot [m]
([m CSF-B] Bottom Core depth (...)

Samp vol [cm3]

Time Stamp
(Of sampling)

Wet m [g]
(Calculated)
10 
Vol wet sample [cm3]
(Calculated)
11 
Samp dm [g]
(Calculated)
12 
Vol dry sample [cm3]
(IODP Method C (Blum, 1997))
13 
Mass pw [g]
(IODP Method C (Blum, 1997))
14 
Salt [g]
(IODP Method C (Blum, 1997))
15 
Mass solids [g]
(IODP Method C (Blum, 1997))
16 
Water wm [%]
(Calculated)
17 
Water dm [%]
(Calculated)
18 
Vol pw [cm3]
(IODP Method C (Blum, 1997))
19 
Vol salt [cm3]
(IODP Method C (Blum, 1997))
20 
Vol solids [cm3]
(IODP Method C (Blum, 1997))
21 
Poros frac
(IODP Method C (Blum, 1997))
22 
Void Ratio
(Calculated (Blum, 1997))
23 
Density [g/cm3]
(Calculated (Blum, 1997))
24 
DBD [g/cm3]
(Calculated (Blum, 1997))
25 
Density grain [g/cm3]
(Calculated (Blum, 1997))
26 
Time Stamp
(Of analysing)
316-C0007B-1H-1,20.03.3403.328316-C0007B-1H-1,22.03.3603.34652008-01-16T06:05:078.6404.9235165.7742.07002.9699480.103948305.6700520.34374400.52379562.9003400.046823542.0231760.58907901.4335581.7548431.1516262.8025492008-01-26T13:18:11
316-C0007B-1H-1,66.03.8003.759316-C0007B-1H-1,67.53.8153.77382008-01-15T10:27:026.5293.7749534.4061.66122.2000000.077000064.3290000.33695820.50820062.1484370.034684711.6265150.56912961.3208841.7295581.1467692.6615182008-01-26T13:18:17
316-C0007B-1H-2,20.04.7454.645316-C0007B-1H-2,22.04.7654.66452008-01-16T06:05:075.9673.4007154.0651.50701.9709850.068984513.9960160.33031410.49323741.9247890.031074101.4759260.56599551.3041231.7546311.1750512.7074642008-01-26T13:18:12
316-C0007B-1H-3,0.05.7305.569316-C0007B-1H-3,1.55.7455.58382008-01-14T19:08:508.1714.2520846.1242.21402.1212440.074243586.0497570.25960640.35063292.0715270.033443052.1805570.48717920.9499991.9216461.4227752.7744092008-01-18T18:16:56
316-C0007B-1H-4,20.06.1655.977316-C0007B-1H-4,22.06.1855.99652008-01-16T06:05:088.4854.3586666.3422.22502.2207250.077725456.2642750.26172370.35450642.1686770.035011462.1899890.49755530.99026871.9466971.4372002.8604142008-01-26T13:18:12
316-C0007B-1H-4,100.06.9656.727316-C0007B-1H-4,102.06.9856.74652008-01-16T06:05:087.8504.3546815.4811.99602.4549220.085922355.3950780.31272900.45503002.3973850.038703761.9572960.55053051.2248451.8026581.2389142.7563932008-01-26T13:18:12
316-C0007B-1H-5,20.07.5707.294316-C0007B-1H-5,22.07.5907.31352008-01-16T06:05:087.2433.8108855.3801.95601.9305700.067570005.3124300.26654290.36340621.8853220.030436941.9255630.49472030.97910181.9006081.3940152.7588972008-01-26T13:18:13
316-C0007B-1H-5,114.08.5108.176316-C0007B-1H-5,116.08.5308.19552008-01-16T06:05:097.7724.3872855.3121.93802.5492230.089222875.2227770.32800090.48809722.4894750.040190481.8978100.56742961.3117621.7714831.1904352.7520032008-01-26T13:18:13
316-C0007B-1H-6,15.08.9208.561316-C0007B-1H-6,16.58.9358.57582008-01-15T11:31:358.2334.1164306.4952.38601.8010360.063036326.4319640.21875820.28001341.7588240.028394742.3576050.42726940.74602162.0000341.5625102.7281772008-01-26T13:18:16
316-C0007B-1H-6,97.09.7409.330316-C0007B-1H-6,99.09.7609.34852008-01-16T06:05:097.6064.2327555.2541.89102.4373060.085305775.1686940.32044510.47155162.3801810.038426021.8525740.56232431.2847971.7969381.2211182.7900072008-01-26T13:18:13
316-C0007B-1H-7,0.09.7709.358316-C0007B-1H-7,1.59.7859.37282008-01-14T19:32:388.1934.5284725.7762.12202.5046630.087663285.6883370.30570770.44031562.4459600.039487962.0825120.54012921.1745241.8092191.2561272.7314782008-01-18T18:16:56
316-C0007B-1H-9,23.010.4509.995316-C0007B-1H-9,25.010.47010.01452008-01-16T06:05:096.6653.6844154.6941.72202.0424870.071487104.6225130.30644970.44185651.9946160.032201401.6897990.54136581.1803871.8089711.2546122.7355412008-01-26T13:18:14
316-C0007B-1H-9,95.011.17010.671316-C0007B-1H-9,97.011.19010.68952008-01-16T06:05:098.6374.3225416.6952.38902.0124350.070435296.6245650.23300170.30378381.9652690.031727612.3572720.45465590.83370461.9981301.5325632.8102672008-01-26T13:18:14
316-C0007B-1H-10,19.011.82011.280316-C0007B-1H-10,21.011.84011.29952008-01-16T06:05:107.6363.8255825.9332.13001.7647670.061766895.8712330.23111140.30057861.7234050.027822922.1021770.45049490.81981921.9960361.5347292.7929302008-01-26T13:18:14
316-C0007B-1H-10,95.012.58011.993316-C0007B-1H-10,97.012.60012.01252008-01-16T06:05:107.8863.8309576.2692.22101.6756480.058647716.2103520.21248390.26981521.6363750.026417892.1945820.42714520.74564292.0584941.6210972.8298562008-01-26T13:18:15