Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Other version:
IODP Hole 316-C0006C, snapshot taken on 2010-08-31, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/316/C0006C/
Coverage:
Latitude: 33.027430 * Longitude: 136.793803
Date/Time Start: 2007-12-28T00:00:00 * Date/Time End: 2007-12-28T00:00:00
Minimum DEPTH, sediment/rock: 0.200 m * Maximum DEPTH, sediment/rock: 9.395 m
Event(s):
316-C0006C * Latitude: 33.027430 * Longitude: 136.793803 * Date/Time: 2007-12-28T00:00:00 * Elevation: -3880.5 m * Recovery: 10.26 m * Campaign: Exp316 (NanTroSEIZE Stage 1: Shallow Megaslay and Frontal Thrusts) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 1 cores; 9.5 m cored; 108 % recovery; 9.5 m drilled; 9.5 m penetrated
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor). Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 314/315/316 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 314/315/316 Scientists[m CSF-B] Top Core depth (below sea floor)
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Average
NumberNoExpedition 314/315/316 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 2
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 3
Time StampTime StampExpedition 314/315/316 ScientistsRegistration
Size:
38 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

k [W/m/K]
(Average, Quick Thermal Conduc...)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

k [W/m/K]
(Run 2, Quick Thermal Conducti...)

k [W/m/K]
(Run 3, Quick Thermal Conducti...)

Time Stamp
(Registration)
316-C0006C-1H-1,20.00.2000.1750.98530.9860.9860.9852007-12-30T10:27:25
316-C0006C-1H-3,45.01.9301.6881.06731.0531.0641.0852007-12-30T10:28:04
316-C0006C-1H-5,40.04.8554.2471.14731.1731.1951.0752007-12-30T10:28:48
316-C0006C-1H-7,40.06.5855.7601.21821.2081.2292007-12-30T10:29:29
316-C0006C-1H-9,43.09.3958.2191.04721.0051.0902007-12-30T10:30:17