Henkel, Susann; Schwenk, Tilmann; Hanebuth, Till J J; Strasser, Michael; Riedinger, Natascha; Formolo, Michael J; Arnold, Gail Lee; Tomasini, Juan; Krastel, Sebastian; Kasten, Sabine (2012): Sulfate and methane concentrations measured in pore water of sediment core GeoB13809-1 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.773286, In supplement to: Henkel, S et al. (2012): Pore water geochemistry as a tool for identifying and dating young mass-transport deposits. In: Yamada, Y et al. (eds.) Advances in Natural and Technological Hazards Research - Submarine Mass Movements and Their Consequences, 5th International Symposium, Springer, 31(1), 87-97, https://doi.org/10.1007/978-94-007-2162-3_8
Always quote citation above when using data! You can download the citation in several formats below.
Project(s):
Coverage:
Latitude: -36.127833 * Longitude: -52.831667
Date/Time Start: 2009-05-25T19:38:00 * Date/Time End: 2009-05-25T19:38:00
Minimum DEPTH, sediment/rock: 0.10 m * Maximum DEPTH, sediment/rock: 9.42 m
Event(s):
GeoB13809-1 (365) * Latitude: -36.127833 * Longitude: -52.831667 * Date/Time: 2009-05-25T19:38:00 * Elevation: -1400.0 m * Recovery: 9.42 m * Campaign: M78/3A * Basis: Meteor (1986) * Method/Device: Gravity corer (GC)
Comment:
Sulfate measurements were performed onboard the ship using a Sykam solvent delivery system coupled to a Waters 430 conductivity detector at a 1:50 dilution. Daily standard calibrations using seawater provided by the International Association for the Physical Sciences of the Oceans (IAPSO) were performed. The range for the 5-point standard calibration was 10 µM - 400 µM.
For methane, a 3 cm**3 sediment sample was transferred into a 20 mL He flushed headspace vial, filled with 10 mL of a 5 M NaCl solution. All samples were taken immediately after the gravity core was retrieved and cut into 1-m segments. Methane concentrations were measured at the Max Planck Institute for Marine Microbiology with a Hewlett Packard 5890A gas chromatograph using a splitless injector, a stainless steel Porapak-Q column and a flame ionization detector. Chromatographic response on the GC instrument was calibrated against three different standards with variable concentrations of methane. Methane concentrations were corrected for sediment porosity.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
2 | Sulfate | [SO4]2- | mmol/l | Henkel, Susann | Sykam solvent delivery system coupled to a Waters 430 conductivity detector | |
3 | Methane | CH4 | mmol/l | Henkel, Susann | Gas chromatography |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
40 data points
Data
1 Depth sed [m] | 2 [SO4]2- [mmol/l] | 3 CH4 [mmol/l] |
---|---|---|
0.10 | 26.2 | |
0.30 | 25.1 | |
0.51 | 0.01 | |
0.60 | 23.7 | |
0.90 | 19.1 | |
1.20 | 19.3 | |
1.51 | 0.02 | |
1.60 | 15.4 | |
1.90 | 14.2 | |
2.20 | 11.9 | |
2.51 | 0.03 | |
2.60 | 7.5 | |
2.90 | 6.3 | |
3.20 | 3.9 | |
3.51 | 0.09 | |
3.60 | 2.5 | |
3.90 | 0.2 | |
4.20 | 0.0 | |
4.51 | 2.78 | |
4.60 | 0.0 | |
4.90 | 0.0 | |
5.20 | 0.0 | |
5.51 | 4.28 | |
5.60 | 0.0 | |
5.90 | 0.0 | |
6.20 | 0.0 | |
6.51 | 6.65 | |
6.60 | 0.0 | |
6.90 | 0.0 | |
7.20 | 0.0 | |
7.51 | 6.28 | |
7.60 | 0.0 | |
7.90 | 0.0 | |
8.20 | 0.0 | |
8.51 | 14.04 | |
8.60 | 0.0 | |
8.90 | 0.0 | |
9.20 | 0.0 | |
9.33 | 0.0 | |
9.42 | 8.45 |