Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Other version:
IODP Hole 315-C0002C, snapshot taken on 2010-11-09, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/315/C0002C/
Coverage:
Latitude: 33.300043 * Longitude: 136.636448
Minimum DEPTH, sediment/rock: 1.485 m * Maximum DEPTH, sediment/rock: 14.285 m
Event(s):
315-C0002C * Latitude: 33.300043 * Longitude: 136.636448 * Elevation: -1936.6 m * Campaign: Exp315 (NanTroSEIZE Stage 1: Megasplay Riser Pilot) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 2 HPCS cores; 13.8 m cored; 99.8 % recovered; 13.77 m drilled;
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor).Standard VLQ laboratory probe, source length is 70 mm and source diameter 2 mm. Measuring range 0.1 - 10 Wm-1K-1.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 314/315/316 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 314/315/316 Scientists[m CSF-B] Top Core depth (below sea floor)
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Average
NumberNoExpedition 314/315/316 ScientistsNumber of runs
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 1
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 2
Conductivity, thermalkW/m/KExpedition 314/315/316 ScientistsQuick Thermal Conductivity Meter QTM-500Run 3
Time StampTime StampExpedition 314/315/316 ScientistsRegistration
Size:
48 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

k [W/m/K]
(Average, Quick Thermal Conduc...)

No
(Number of runs)

k [W/m/K]
(Run 1, Quick Thermal Conducti...)

k [W/m/K]
(Run 2, Quick Thermal Conducti...)

k [W/m/K]
(Run 3, Quick Thermal Conducti...)

Time Stamp
(Registration)
315-C0002C-1H-2,30.01.4851.4850.97830.9720.9790.9842008-02-26T03:51:41
315-C0002C-1H-4,30.04.2974.2971.06431.0721.0621.0602007-12-18T06:57:27
315-C0002C-2H-2,51.08.8508.5811.00730.9971.0061.0182007-12-18T06:58:02
315-C0002C-2H-4,119.012.35011.5981.08131.0631.0811.1002010-09-29T10:04:47
315-C0002C-2H-5,119.013.76512.8180.92630.8671.1000.8122007-12-18T06:37:02
315-C0002C-2H-6,30.014.28513.2660.99531.0000.9900.9972010-09-29T10:07:21