Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science
Related to:
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Kinoshita, Masataka; Tobin, Harold; Ashi, Juichiro; Kimura, Gaku; Lallemant, Siegfried J; Screaton, Elizabeth J; Curewitz, Daniel; Masago, Hideki; Moe, Kyaw Thu; Expedition 314/315/316 Scientists (2009): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 314/315/316, https://doi.org/10.2204/iodp.proc.314315316.133.2009
Other version:
IODP Hole 315-C0002B, snapshot taken on 2011-04-14, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/315/C0002B/
Coverage:
Latitude: 33.299880 * Longitude: 136.636715
Minimum DEPTH, sediment/rock: 477.355 m * Maximum DEPTH, sediment/rock: 641.215 m
Event(s):
315-C0002B * Latitude: 33.299880 * Longitude: 136.636715 * Elevation: -1937.5 m * Campaign: Exp315 (NanTroSEIZE Stage 1: Megasplay Riser Pilot) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 66 RCB cores; 582 m cored; 35.8 % recovered; 1057 m drilled;
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 314/315/316 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 314/315/316 Scientists[m CSF-B] Top Core depth (below sea floor)
Penetration strengthPenetr strengthkPaExpedition 314/315/316 ScientistsFall cone penetration test
Time StampTime StampExpedition 314/315/316 ScientistsRegistration
Size:
116 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

Penetr strength [kPa]

Time Stamp
315-C0002B-1R-3,61.5477.355477.35598.12008-02-26T02:12:57
315-C0002B-1R-3,116.5477.905477.905147.22008-02-26T02:12:57
315-C0002B-2R-1,29.5484.795484.79536.82008-02-26T02:12:57
315-C0002B-3R-1,93.0494.930494.93036.82008-02-26T02:12:57
315-C0002B-4R-1,78.0504.280504.28029.42008-02-26T02:12:58
315-C0002B-4R-3,26.0505.180505.18039.22008-02-26T02:12:58
315-C0002B-5R-1,52.0508.520508.52044.12008-02-26T02:12:58
315-C0002B-7R-1,16.0523.660523.660103.02008-02-26T02:12:58
315-C0002B-8R-1,97.5533.975533.97593.22008-02-26T02:12:59
315-C0002B-8R-3,51.0535.235535.235103.02008-02-26T02:12:59
315-C0002B-9R-1,108.5543.585543.585107.92008-02-26T02:12:59
315-C0002B-9R-4,26.5545.570545.570107.92008-02-26T02:12:59
315-C0002B-10R-1,90.5552.905552.905206.02008-02-26T02:12:52
315-C0002B-10R-3,94.5554.665554.66544.12008-02-26T02:12:53
315-C0002B-11R-1,116.0562.660562.66024.52008-02-26T02:12:53
315-C0002B-11R-5,61.0566.332566.33298.12008-02-26T02:12:53
315-C0002B-12R-1,106.5572.065572.06558.92008-02-26T02:12:53
315-C0002B-12R-3,47.0574.290574.290161.92008-02-26T02:12:54
315-C0002B-13R-3,94.0583.170583.17093.22008-02-26T02:12:54
315-C0002B-14R-1,103.0591.030591.030245.32008-02-26T02:12:54
315-C0002B-14R-2,123.0592.645592.645313.92008-02-26T02:12:54
315-C0002B-15R-1,104.0600.540600.540134.92008-02-26T02:12:55
315-C0002B-15R-2,128.0602.190602.190110.42008-02-26T02:12:55
315-C0002B-16R-1,71.0609.710609.71073.62008-02-26T02:12:55
315-C0002B-17R-2,80.0620.715620.715107.92008-02-26T02:12:56
315-C0002B-17R-4,96.5623.690623.690304.12008-02-26T02:12:56
315-C0002B-18R-1,67.5628.675628.67558.92008-02-26T02:12:56
315-C0002B-19R-1,115.5638.655638.65568.72008-02-26T02:12:56
315-C0002B-19R-4,49.0641.215641.215132.42008-02-26T02:12:57