Kaneko, Masanori; Shingai, Hiroshi; Pohlman, John W; Naraoka, Hiroshi (2010): (Table 2) Concentration of biomarkers in hydrocarbon fractions from IODP Holes 311-U1327C, 311-U1328B and 311-U1328C [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.763879, In supplement to: Kaneko, M et al. (2010): Chemical and isotopic signature of bulk organic matter and hydrocarbon biomarkers within mid-slope accretionary sediments of the northern Cascadia margin gas hydrate system. Marine Geology, 275(1-4), 166-177, https://doi.org/10.1016/j.margeo.2010.05.010
Always quote citation above when using data! You can download the citation in several formats below.
Project(s):
Coverage:
Median Latitude: 48.677744 * Median Longitude: -126.855633 * South-bound Latitude: 48.667467 * West-bound Longitude: -126.865233 * North-bound Latitude: 48.698150 * East-bound Longitude: -126.850733
Minimum DEPTH, sediment/rock: 3.75 m * Maximum DEPTH, sediment/rock: 297.15 m
Event(s):
311-U1327C * Latitude: 48.698150 * Longitude: -126.865233 * Elevation: -1304.5 m * Recovery: 262.17 m * Campaign: Exp311 (Cascadia Margin Gas Hydrates) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 35 cores; 297 m cored; 88.3 % recovered; 3 m drilled; 300 m penetrated
311-U1328B * Latitude: 48.667467 * Longitude: -126.850933 * Elevation: -1267.8 m * Recovery: 39.65 m * Campaign: Exp311 (Cascadia Margin Gas Hydrates) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 10 cores; 54.5 m cored; 72.8 % recovered; 2 m drilled; 56.5 m penetrated
311-U1328C * Latitude: 48.667617 * Longitude: -126.850733 * Elevation: -1267.7 m * Recovery: 195.64 m * Campaign: Exp311 (Cascadia Margin Gas Hydrates) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 27 cores; 242.5 m cored; 80.7 % recovered; 57.5 m drilled; 300 m penetrated
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | ||||
2 | Sample code/label | Sample label | Kaneko, Masanori | DSDP/ODP/IODP sample designation | ||
3 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
4 | Pristane | Pr | µg/g | Kaneko, Masanori | ||
5 | Phytane | Phy | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) | |
6 | Phytene | Phytene | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) | Phytene I |
7 | Phytene | Phytene | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) | Phytene II |
8 | 2,6,10,15,19-pentamethylicosane | PMI | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) | |
9 | Diploptene | Diploptene | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) | |
10 | Hop-21-ene | Hop-21-ene | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) | |
11 | C37:3-alkene | C37:3-alkene | µg/g | Kaneko, Masanori | Gas chromatography - Flame Ionization Detection (GC-FID) |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
226 data points
Data
1 Event | 2 Sample label (DSDP/ODP/IODP sample designation) | 3 Depth sed [m] | 4 Pr [µg/g] | 5 Phy [µg/g] (Gas chromatography - Flame Io...) | 6 Phytene [µg/g] (Phytene I, Gas chromatography...) | 7 Phytene [µg/g] (Phytene II, Gas chromatograph...) | 8 PMI [µg/g] (Gas chromatography - Flame Io...) | 9 Diploptene [µg/g] (Gas chromatography - Flame Io...) | 10 Hop-21-ene [µg/g] (Gas chromatography - Flame Io...) | 11 C37:3-alkene [µg/g] (Gas chromatography - Flame Io...) |
---|---|---|---|---|---|---|---|---|---|---|
311-U1327C | 311-U1327C-1H-3,75-80 | 3.75 | 9.8 | 4.9 | 1.5 | 1.5 | 0.9 | 4.9 | 0.0 | |
311-U1327C | 311-U1327C-2H-3,75-80 | 9.85 | 3.7 | 1.9 | 0.5 | 0.7 | 0.6 | 12.5 | 0.0 | |
311-U1327C | 311-U1327C-2H-5,125-130 | 13.35 | 7.5 | 3.2 | 2.6 | 2.1 | 0.7 | 4.8 | 3.4 | 0.0 |
311-U1327C | 311-U1327C-3H-2,135-140 | 18.45 | 1.1 | 0.4 | 0.3 | 0.8 | 0.5 | 2.1 | 0.4 | 0.4 |
311-U1327C | 311-U1327C-7H-2,130-135 | 48.90 | 5.0 | 2.3 | 0.7 | 1.3 | 0.5 | 0.4 | 0.2 | 0.0 |
311-U1327C | 311-U1327C-9H-2,115-120 | 67.75 | 5.5 | 1.7 | 0.8 | 1.4 | 2.3 | 8.1 | 6.7 | 2.1 |
311-U1327C | 311-U1327C-13X-6,23-28 | 109.69 | 1.4 | 0.5 | 0.7 | 0.9 | 0.4 | 1.9 | 5.0 | 10.9 |
311-U1327C | 311-U1327C-20X-4,7-12 | 164.65 | 1.6 | 0.7 | 1.8 | 2.4 | 0.3 | 2.9 | 1.8 | |
311-U1327C | 311-U1327C-25X-2,100-115 | 201.11 | 4.9 | 1.8 | 4.1 | 4.4 | 1.4 | 5.1 | 1.8 | |
311-U1327C | 311-U1327C-28X-3,0-5 | 230.95 | 4.5 | 1.6 | 7.0 | 6.8 | 1.5 | 4.3 | 0.8 | |
311-U1327C | 311-U1327C-35X-2,15-20 | 297.15 | 2.6 | 1.1 | 3.1 | 2.9 | 0.2 | 1.2 | 0.0 | |
311-U1328B | 311-U1328B-1H-5,70-80 | 3.80 | 1.8 | 0.8 | 0.5 | 1.0 | 1.4 | 0.6 | 0.3 | |
311-U1328B | 311-U1328B-5H-2,38-48 | 17.78 | 1.4 | 0.6 | 0.6 | 1.3 | 0.5 | |||
311-U1328B | 311-U1328B-6X-2,30-40 | 19.85 | 1.6 | 0.7 | 0.5 | 1.0 | 1.6 | 0.7 | ||
311-U1328B | 311-U1328B-6X-2,80-90 | 20.35 | 3.5 | 1.6 | 1.9 | 2.2 | 1.8 | 1.5 | ||
311-U1328B | 311-U1328B-9H-4,45-55 | 42.91 | 5.4 | 2.1 | 1.9 | 3.8 | 0.9 | 6.6 | 4.0 | |
311-U1328B | 311-U1328B-10H-4,55-65 | 52.05 | 4.3 | 1.6 | 1.5 | 2.8 | 0.6 | 5.0 | 3.7 | 2.1 |
311-U1328C | 311-U1328C-4X-2,55-65 | 87.05 | 7.3 | 2.0 | 1.4 | 2.4 | 0.6 | 1.7 | ||
311-U1328C | 311-U1328C-6H-7,43-53 | 100.32 | 2.1 | 1.2 | 1.8 | 3.8 | 0.4 | 1.2 | 1.9 | 2.3 |
311-U1328C | 311-U1328C-10X-2,0-22 | 131.10 | 3.1 | 1.7 | 5.0 | 6.7 | 3.3 | 1.3 | 1.7 | 42.0 |
311-U1328C | 311-U1328C-11X-2,11-120 | 141.90 | 1.4 | 0.7 | 2.0 | 3.5 | 0.2 | 1.6 | 1.9 | 6.1 |
311-U1328C | 311-U1328C-13X-2,110-120 | 161.17 | 3.6 | 3.5 | 3.9 | 0.7 | 1.0 | 2.1 | 1.3 | |
311-U1328C | 311-U1328C-14X-4,80-90 | 173.33 | 0.8 | 0.4 | 4.1 | 6.2 | 1.2 | 1.5 | 3.8 | 18.6 |
311-U1328C | 311-U1328C-19X-2,30-40 | 217.23 | 2.3 | 1.2 | 1.3 | 2.2 | 0.5 | 1.7 | 1.0 | |
311-U1328C | 311-U1328C-20X-3,110-120 | 229.45 | 2.5 | 1.4 | 4.1 | 6.0 | 0.9 | 3.1 | 1.7 | |
311-U1328C | 311-U1328C-22X-4,50-60 | 249.31 | 10.5 | 7.6 | 3.6 | 4.4 | 5.0 | 4.0 | ||
311-U1328C | 311-U1328C-24X-3,65-75 | 268.01 | 7.0 | 3.4 | 2.9 | 4.0 | 1.3 | 1.8 | ||
311-U1328C | 311-U1328C-27X-3,70-80 | 297.10 | 2.6 | 1.2 | 1.6 | 1.6 | 0.3 | 1.0 |