Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Weihe, Ellen; Abele, Doris; Stölting, Ilse (2010): Physiological measurements in the gill tissue of subtidal Antarctic limpets (Nacella concinna) from Potter Cove, King George Island, West Antarctic Peninsula in 2005 [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.753760

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Weihe, Ellen; Abele, Doris (2008): Differences in the physiological response of inter- and subtidal Antarctic limpets Nacella concinna to aerial exposure. Aquatic Biology, 4, 155-166, https://doi.org/10.3354/ab00103
Weihe, Ellen; Kriews, Michael; Abele, Doris (2010): Differences in heavy metal concentrations and in the response of the antioxidant system to hypoxia and air exposure in the Antarctic limpet Nacella concinna. Marine Environmental Research, 69(3), 127-135, https://doi.org/10.1016/j.marenvres.2009.09.003
Coverage:
Latitude: -62.233300 * Longitude: -58.716700
Event(s):
PotterCove_Nacella * Latitude: -62.233300 * Longitude: -58.716700 * Location: Potter Cove, King George Island, Antarctic Peninsula * Campaign: Jubany_Dallmann * Basis: Carlini/Jubany Station * Method/Device: Biology (BIO)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Sample code/labelSample labelWeihe, Ellen
2IronFeµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry259.9 nm
3AluminiumAlµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry396.1 nm
4CalciumCaµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry315.8 nm
5CalciumCaµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry317.9 nm
6PotassiumKµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry766.4 nm
7MagnesiumMgµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry279.5 nm
8MagnesiumMgµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry285.2 nm
9SodiumNaµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry589.5 nm
10ZincZnµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry206.2 nm
11ZincZnµg/gStölting, IlseICP-OES, Inductively coupled plasma - optical emission spectrometry213.8 nm
12CadmiumCdµg/gStölting, IlseGraphite furnace atomic absorption spectrometer (GF-AAS)
13Glutathione, reduced, per wet massGSHnmol/gWeihe, EllenHigh Performance Liquid Chromatography (HPLC)
14Glutathione, oxidized, per wet massGSSGnmol/gWeihe, EllenHigh Performance Liquid Chromatography (HPLC)
15Glutathione, total, reduced, per wet massTGSHnmol/gWeihe, EllenCalculated
16Glutathione oxidized/Glutathione reduced, ratioGSSG/GSH ratioWeihe, EllenCalculated
17Oxidation reduction (RedOx) potentialEhmVWeihe, EllenIon selective probe
18pHpHWeihe, Ellen
Size:
115 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML