Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Katz, Barry J (1988): (Table 2) Elemental and isotope analyses of isolated kerogens for ODP Hole 101-635B [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.743273, In supplement to: Katz, BJ (1988): Organic-geochemical character and hydrocarbon-source potential of Site 635. In: Austin, JA Jr.; Schlager, W; et al. (eds.), Proceedings of the Ocean Drilling Program, Scientific Results, College Station, TX (Ocean Drilling Program), 101, 381-388, https://doi.org/10.2973/odp.proc.sr.101.159.1988

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 25.419700 * Longitude: -77.333000
Date/Time Start: 1985-03-09T17:03:00 * Date/Time End: 1985-03-11T19:00:00
Minimum DEPTH, sediment/rock: 61.53 m * Maximum DEPTH, sediment/rock: 116.87 m
Event(s):
101-635B * Latitude: 25.419700 * Longitude: -77.333000 * Date/Time Start: 1985-03-09T17:03:00 * Date/Time End: 1985-03-11T19:00:00 * Elevation: -3483.0 m * Penetration: 117.7 m * Recovery: 31.3 m * Location: South Atlantic Ocean * Campaign: Leg101 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 14 cores; 117.7 m cored; 0 m drilled; 26.6 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelKatz, Barry JDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
HydrogenH%Katz, Barry J
CarbonC%Katz, Barry J
Oxygen, gasO2%Katz, Barry J
Nitrogen, totalTN%Katz, Barry J
Ash, volcanicVolc ash%Katz, Barry J
Hydrogen/Carbon ratioH/CKatz, Barry J
Oxygen/Carbon ratioO/CKatz, Barry J
10 δ13Cδ13C‰ PDBKatz, Barry Jper mil PDB
Size:
180 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

H [%]

C [%]

O2 [%]

TN [%]

Volc ash [%]

H/C

O/C
10 
δ13C [‰ PDB]
101-635B-8R-1,53-5761.535.2959.6214.512.318.731.060.183-26.79
101-635B-8R-1,115-11862.1559.63-27.07
101-635B-8R-CC,3-670.534.1848.444.251.8210.311.030.066-26.69
101-635B-9R-1,40-4371.005.1957.6210.681.9914.511.070.139-26.63
101-635B-9R-1,87-9071.475.7063.7912.022.666.221.070.141-26.40
101-635B-10R-1,15-1880.3538.39-26.29
101-635B-10R-2,56-6082.265.4763.8512.372.196.831.020.146-25.89
101-635B-10R-2,73-7782.435.2759.789.522.306.331.050.120-26.41
101-635B-10R-3,67-7083.875.2258.8313.332.496.841.060.170-26.64
101-635B-10R-3,83-8684.035.1358.3412.082.160.361.050.155-26.21
101-635B-10R-CC,0-589.404.2051.1611.411.8521.630.980.167-26.56
101-635B-11R-1,61-6490.215.0160.0110.363.103.221.000.130-26.64
101-635B-11R-1,88-9290.485.1259.529.773.215.641.020.123-26.38
101-635B-11R-2,26-3091.363.7545.0310.342.102.690.990.172-26.51
101-635B-11R-3,5-992.654.6658.1610.075.5022.040.950.130-26.49
101-635B-12R-1,60-6299.705.2356.704.750.6614.661.100.063-26.46
101-635B-12R-2,30-32100.903.0435.006.060.005.051.040.130-26.41
101-635B-12R-3,12-15102.223.8844.347.310.0020.431.050.124-25.62
101-635B-13R-1,11-13108.4138.71-25.56
101-635B-13R-2,7-10109.872.9141.169.220.0013.780.840.168-25.59
101-635B-13R-2,105-109110.854.3957.5012.190.2729.200.910.159-25.60
101-635B-14R-3, 145-149116.873.2750.8010.830.0021.770.770.160-25.67