Stemmann, Lars; Picheral, Marc; Gorsky, G (2000): Vertical distribution of suspended aggregates at time series station DYNAPROC [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.738720, Supplement to: Stemmann, L et al. (2000): Diel variation in the vertical distribution of particulate matter (>0.15 mm) in the NW Mediterranean Sea investigated with the Underwater Video Profiler. Deep Sea Research Part I: Oceanographic Research Papers, 47(1), 505-531, https://doi.org/10.1016/S0967-0637(99)00100-4
Always quote citation above when using data! You can download the citation in several formats below.
Abstract:
Day/night variations in the size distribution of the particulate matter >0.15 mm (PM) were studied in May 1995 during the DYNAPROC time-series cruise in the northwestern Mediterranean Sea. Data on vertical distributions of PM (>0.15 mm) and zooplankton were collected with the Underwater Video Profiler (UVP). The comparisons of the UVP data with plankton net data and POC data from water bottles indicated that more than 97% of the particles detected by the UVP were non-living particles (0.15 mm) and that the PM contributed 4-34% of the total dry weight measured on GF/F filters. Comparison of seven pairs of day and night vertical profiles performed during the cruise showed that in the upper 800 m, the mean size and the volume of particles was higher at night than during the day. During the night, the integrated volume of the PM increased on average by 32±20%. This increase corresponded to a shift of smaller size classes (<0.5 mm) towards the larger ones (>0.5 mm). During the day, the pattern was reversed, and the quantity of PM >0.5 mm decreased. During the study period, the standing stock of PM (60-800 m) decreased from 7.5 to less than 2 g m?2 but the diel variations persisted, except for two short periods in the superficial layer following a wind event. The cyclic feeding activity induced by the diel vertical migration of zooplankton could be the best candidate to explain the observed diel fluctuations in the size classes of PM in the water column. However, our results also suggest that in the upper layer additional driving forces such as the increase of the level of turbulence after a wind event or the modification of the zoo- and phytoplankton community can influence the PM temporal evolution.
Project(s):
Funding:
Sixth Framework Programme (FP6), grant/award no. 36949: Southern European Seas: Assessing and Modelling Ecosystem Changes
Coverage:
Median Latitude: 43.251631 * Median Longitude: 7.517960 * South-bound Latitude: 43.247700 * West-bound Longitude: 7.512000 * North-bound Latitude: 43.254600 * East-bound Longitude: 7.521500
Date/Time Start: 1995-05-10T14:00:00 * Date/Time End: 1995-05-31T16:50:00
Event(s):
DYNAPROC_PVM01 * Latitude: 43.251000 * Longitude: 7.518300 * Date/Time: 1995-05-10T14:00:00 * Campaign: DYNAPROC * Basis: Le Suroît * Method/Device: Underwater video profiler (UVP)
DYNAPROC_PVM07 * Latitude: 43.250500 * Longitude: 7.518200 * Date/Time: 1995-05-12T01:20:00 * Campaign: DYNAPROC * Basis: Le Suroît * Method/Device: Underwater video profiler (UVP)
DYNAPROC_PVM08 * Latitude: 43.251500 * Longitude: 7.515900 * Date/Time: 1995-05-12T16:46:00 * Campaign: DYNAPROC * Basis: Le Suroît * Method/Device: Underwater video profiler (UVP)
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
45 datasets
Download Data
Datasets listed in this publication series
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM01. https://doi.org/10.1594/PANGAEA.185053
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM01. https://doi.org/10.1594/PANGAEA.185079
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM07. https://doi.org/10.1594/PANGAEA.185054
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM07. https://doi.org/10.1594/PANGAEA.185080
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM08. https://doi.org/10.1594/PANGAEA.185081
- Stemmann, L; Picheral, M; Gorsky, G (2005): Number of particles at station DYNAPROC_PVM09. https://doi.org/10.1594/PANGAEA.185056
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM09. https://doi.org/10.1594/PANGAEA.185082
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM10. https://doi.org/10.1594/PANGAEA.185057
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM10. https://doi.org/10.1594/PANGAEA.185083
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM11. https://doi.org/10.1594/PANGAEA.185058
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM11. https://doi.org/10.1594/PANGAEA.185084
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM12. https://doi.org/10.1594/PANGAEA.185059
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM12. https://doi.org/10.1594/PANGAEA.185085
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM17. https://doi.org/10.1594/PANGAEA.185060
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM17. https://doi.org/10.1594/PANGAEA.185086
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM18. https://doi.org/10.1594/PANGAEA.185061
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM18. https://doi.org/10.1594/PANGAEA.185087
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM20. https://doi.org/10.1594/PANGAEA.185062
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM20. https://doi.org/10.1594/PANGAEA.185088
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM21. https://doi.org/10.1594/PANGAEA.185063
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM21. https://doi.org/10.1594/PANGAEA.185089
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM24. https://doi.org/10.1594/PANGAEA.185064
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM24. https://doi.org/10.1594/PANGAEA.185090
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM25. https://doi.org/10.1594/PANGAEA.185065
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM25. https://doi.org/10.1594/PANGAEA.185091
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM26. https://doi.org/10.1594/PANGAEA.185066
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM26. https://doi.org/10.1594/PANGAEA.185092
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM27. https://doi.org/10.1594/PANGAEA.185067
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM27. https://doi.org/10.1594/PANGAEA.185093
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM28. https://doi.org/10.1594/PANGAEA.185068
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM28. https://doi.org/10.1594/PANGAEA.185094
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM29. https://doi.org/10.1594/PANGAEA.185095
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM32. https://doi.org/10.1594/PANGAEA.185070
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM32. https://doi.org/10.1594/PANGAEA.185096
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM33. https://doi.org/10.1594/PANGAEA.185071
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM33. https://doi.org/10.1594/PANGAEA.185097
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM35. https://doi.org/10.1594/PANGAEA.185072
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM35. https://doi.org/10.1594/PANGAEA.185098
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM36. https://doi.org/10.1594/PANGAEA.185073
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM36. https://doi.org/10.1594/PANGAEA.185099
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM37. https://doi.org/10.1594/PANGAEA.185100
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM38. https://doi.org/10.1594/PANGAEA.185075
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM38. https://doi.org/10.1594/PANGAEA.185101
- Stemmann, L; Picheral, M; Gorsky, G (2000): Number of particles at station DYNAPROC_PVM39. https://doi.org/10.1594/PANGAEA.185076
- Stemmann, L; Picheral, M; Gorsky, G (2000): Vertical distribution of suspended aggregates at station DYNAPROC_PVM39. https://doi.org/10.1594/PANGAEA.185102