Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Roters, Bastian; Henrich, Rüdiger (2010): Carbonate and organic carbon content of ODP Hole 175-1085A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.738687, In supplement to: Roters, B; Henrich, R (2010): The middle to late Miocene climatic development of Southwest Africa derived from the sedimentological record of ODP Site 1085A. International Journal of Earth Sciences, 99(2), 459-471, https://doi.org/10.1007/s00531-008-0398-9

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: -29.374410 * Longitude: 13.990110
Date/Time Start: 1997-09-26T00:15:00 * Date/Time End: 1997-09-29T18:15:00
Minimum DEPTH, sediment/rock: 518.30 m * Maximum DEPTH, sediment/rock: 594.18 m
Event(s):
175-1085A * Latitude: -29.374410 * Longitude: 13.990110 * Date/Time Start: 1997-09-26T00:15:00 * Date/Time End: 1997-09-29T18:15:00 * Elevation: -1713.2 m * Penetration: 604 m * Recovery: 594.39 m * Location: Benguela Current, South Atlantic Ocean * Campaign: Leg175 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 64 cores; 604 m cored; 0 m drilled; 98.4 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelRoters, BastianDSDP/ODP/IODP sample designation
AGEAgeka BPGeocode
DEPTH, sediment/rockDepth sedmGeocode
Depth, compositeDepth compmcdRoters, BastianIntercore correlation
Calcium carbonateCaCO3%Roters, BastianCalculated, CaCO3=(TC-TOC)*8.333Total carbonate clay fraction
Calcium carbonateCaCO3%Roters, BastianCalculated, CaCO3=(TC-TOC)*8.333Total carbonate silt fraction
Calcium carbonateCaCO3%Roters, BastianCalculated, CaCO3=(TC-TOC)*8.333Total carbonate sand fraction
Calcium carbonateCaCO3%Roters, BastianCalculated, CaCO3=(TC-TOC)*8.333Total carbonate bulk fraction
Carbon, organic, totalTOC%Roters, BastianElement analyser CS, LECO CS-200Total organic carbon bulk fraction
Size:
204 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Age [ka BP]

Depth sed [m]

Depth comp [mcd]
(Intercore correlation)

CaCO3 [%]
(Total carbonate clay fraction...)

CaCO3 [%]
(Total carbonate silt fraction...)

CaCO3 [%]
(Total carbonate sand fraction...)

CaCO3 [%]
(Total carbonate bulk fraction...)

TOC [%]
(Total organic carbon bulk fra...)
175-1085A-56X-02,110-11210975.0518.30546.4644.5087.19100.0063.400.43
175-1085A-56X-06,126-12811123.0526.96552.6246.7883.94100.0059.740.71
175-1085A-57X-03,32-3411201.0530.22556.8130.9676.39100.0049.150.43
175-1085A-57X-06,58-6011302.0534.98561.4631.0184.08100.0056.600.40
175-1085A-58X-03,60-6211401.0540.20566.7725.3775.98100.0043.140.22
175-1085A-59X-01,20-2211501.0546.40573.0525.8877.75100.0045.120.26
175-1085A-56X-03,96-9811599.0550.08576.5934.7879.90100.0052.960.18
175-1085A-59X-06,22-2411701.0553.84580.2335.0780.99100.0059.870.28
175-1085A-60X-01,0-211821.0555.80582.4626.2075.10100.00
175-1085A-60X-02,30-3211905.5557.60584.2225.7777.41100.0042.800.30
175-1085A-60X-03,70-7212001.0559.50586.0922.5474.36100.0040.040.34
175-1085A-60X-05,36-3812100.0562.16588.6942.9084.70100.0057.640.43
175-1085A-60X-06,118-12012200.5564.48590.9737.8284.19100.0061.210.32
175-1085A-61X-01,0-212308.5565.50592.1630.8277.48100.00
175-1085A-61X-02,64-6612399.5567.64594.2422.3070.98100.0037.850.21
175-1085A-61X-04,5-712494.0569.90596.5951.8683.94100.0067.130.31
175-1085A-61X-05,110-11212592.5572.45599.0740.7682.55100.0057.180.17
175-1085A-61X-07,36-3812683.0574.72601.2946.6586.61100.0065.040.21
175-1085A-62-01,130-13212800.5576.40603.0149.5286.61100.0065.630.22
175-1085A-62-03,58-6012909.0578.70605.2138.9584.53100.0059.370.15
175-1085A-62X-04,110-11213020.0580.72607.1539.5384.76100.0058.240.34
175-1085A-62X-05,124-12613102.5582.37608.7334.3480.58100.0059.660.28
175-1085A-62X-06,90-9213201.5583.55609.8743.1285.49100.0060.840.18
175-1085A-62X-07,76-7813300.0584.63610.9237.5185.00100.0061.450.48
175-1085A-63X-01,140-14213397.0586.10612.7373.1693.22100.0082.560.23
175-1085A-63X-02,144-14613537.0587.64614.2328.3373.75100.0041.680.14
175-1085A-63X-04,20-2213600.5589.40615.9445.8281.84100.00
175-1085A-63X-05,58-6013699.0591.28617.7838.4882.85100.0064.670.22
175-1085A-63X-06,78-8013800.0592.98619.4336.0281.63100.0055.140.21
175-1085A-63X-07,48-5013891.5594.18620.6016.0850.06100.0024.040.22