Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

MacLeod, Kenneth G; Martin, Ellen E; Blair, Susanna W (2008): (Table S1) Nd and Sm isotopic data for samples from ODP Hole 207-1258B [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.722604, In supplement to: MacLeod, KG et al. (2008): Nd isotopic excursion across Cretaceous ocean anoxic event 2 (Cenomanian-Turonian) in the tropical North Atlantic. Geology, 36(10), 811-814, https://doi.org/10.1130/G24999A.1

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 9.433330 * Longitude: -54.733030
Date/Time Start: 2003-01-25T10:10:00 * Date/Time End: 2003-10-28T10:10:00
Minimum DEPTH, sediment/rock: 398.46 m * Maximum DEPTH, sediment/rock: 429.99 m
Event(s):
207-1258B * Latitude: 9.433330 * Longitude: -54.733030 * Date/Time Start: 2003-01-25T10:10:00 * Date/Time End: 2003-10-28T10:10:00 * Elevation: -3192.2 m * Penetration: 460.9 m * Recovery: 346.13 m * Location: South Atlantic Ocean * Campaign: Leg207 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 57 cores; 453.9 m cored; 7 m drilled; 76.3 % recovery
Parameter(s):
Size:
80 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth comp [mcd]

Age [ka BP]

Instrument

143Nd/144Nd

143Nd/144Nd e [±]

ε-Nd(0)

ε-Nd(T)
10 
ε-Nd std dev [±]
207-1258B-45R-1,96-97398.46419.2993.00Nu multi-collector inductively coupled mass spectrometer0.51184900.000008-15.4-14.50.2
207-1258B-45R-3,36-37399.71420.5493.12Nu multi-collector inductively coupled mass spectrometer0.51186400.000005-15.1-14.20.0
207-1258B-45R-3,51-52399.86420.6993.14Micromass Sector 54 thermal ionization mass spectrometer0.51178300.000011-16.7-15.80.2
207-1258B-47R-1,23-24.5407.33429.3994.38Nu multi-collector inductively coupled mass spectrometer0.51191700.000010-14.1-13.20.2
207-1258B-48R-1,111-112.5413.81435.8795.03Nu multi-collector inductively coupled mass spectrometer0.51176400.000004-17.1-16.20.1
207-1258B-49R-1,44-45.5417.14439.2095.36Micromass Sector 54 thermal ionization mass spectrometer0.51182200.000008-15.9-15.10.2
207-1258B-49R-1,44-45.5417.14439.2095.36Micromass Sector 54 thermal ionization mass spectrometer0.51184000.000006-15.6-14.70.1
207-1258B-49R-3,30-31.5419.67441.7395.61Micromass Sector 54 thermal ionization mass spectrometer0.51185300.000009-15.3-14.50.2
207-1258B-49R-3,30-31.5419.67441.7395.61Micromass Sector 54 thermal ionization mass spectrometer0.51185900.000008-15.2-14.30.2