Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

MacLeod, Kenneth G; Martin, Ellen E; Blair, Susanna W (2008): (Table S1) Nd and Sm isotopic data for samples from ODP Hole 207-1258A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.722603, In supplement to: MacLeod, KG et al. (2008): Nd isotopic excursion across Cretaceous ocean anoxic event 2 (Cenomanian-Turonian) in the tropical North Atlantic. Geology, 36(10), 811-814, https://doi.org/10.1130/G24999A.1

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 9.433330 * Longitude: -54.733310
Date/Time Start: 2003-01-22T18:15:00 * Date/Time End: 2003-01-25T10:10:00
Minimum DEPTH, sediment/rock: 352.32 m * Maximum DEPTH, sediment/rock: 434.76 m
Event(s):
207-1258A * Latitude: 9.433330 * Longitude: -54.733310 * Date/Time Start: 2003-01-22T18:15:00 * Date/Time End: 2003-01-25T10:10:00 * Elevation: -3192.2 m * Penetration: 447.5 m * Recovery: 375.46 m * Location: North Atlantic Ocean * Campaign: Leg207 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 50 cores; 447.5 m cored; 0 m drilled; 83.9 % recovery
Size:
236 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth comp [mcd]

Age [ka BP]

Instrument

143Nd/144Nd

143Nd/144Nd e [±]

ε-Nd(0)

ε-Nd(T)
10 
ε-Nd std dev [±]
11 
147Sm/144Nd
207-1258A-38R-1,102-108352.32375.1975.00Micromass Sector 54 thermal ionization mass spectrometer0.51180400.000008-16.3-15.40.2
207-1258A-42R-1,8-10389.88414.8392.55Micromass Sector 54 thermal ionization mass spectrometer0.51182400.000009-15.9-15.00.2
207-1258A-42R-1,8-10389.88414.8392.55Micromass Sector 54 thermal ionization mass spectrometer0.51182500.000007-15.9-15.00.1
207-1258A-42R-1,65-66.5390.45415.4092.61Micromass Sector 54 thermal ionization mass spectrometer0.51187200.000008-15.0-14.10.2
207-1258A-42R-1,65-66.5390.45415.4092.61Micromass Sector 54 thermal ionization mass spectrometer0.51186600.000009-15.1-14.20.2
207-1258A-42R-3,60-62393.29418.2492.89Nu multi-collector inductively coupled mass spectrometer0.51187800.000005-14.8-13.90.10.1250
207-1258A-42R-5,12-15395.34420.2993.10Nu multi-collector inductively coupled mass spectrometer0.51184100.000005-15.5-14.70.1
207-1258A-42R-6,2-4396.56421.5193.22Nu multi-collector inductively coupled mass spectrometer0.51194500.000006-13.5-12.60.1
207-1258A-42R-6,32-34396.86421.8193.25Nu multi-collector inductively coupled mass spectrometer0.51183400.000005-15.7-14.80.10.1256
207-1258A-42R-6,60-62397.14422.0993.28Nu multi-collector inductively coupled mass spectrometer0.51194000.000005-13.6-12.70.1
207-1258A-42R-6,65-66.5397.19422.1493.65Micromass Sector 54 thermal ionization mass spectrometer0.51202800.000006-11.9-11.00.1
207-1258A-42R-6,65-66.5397.19422.1493.65Micromass Sector 54 thermal ionization mass spectrometer0.51201600.000009-12.1-11.30.2
207-1258A-42R-6,95-96.5397.49422.4493.68Micromass Sector 54 thermal ionization mass spectrometer0.51193800.000008-13.7-12.80.2
207-1258A-42R-6,95-96.5397.49422.4493.68Micromass Sector 54 thermal ionization mass spectrometer0.51193300.000011-13.8-12.90.2
207-1258A-42R-6,115-116.5397.69422.6493.70Micromass Sector 54 thermal ionization mass spectrometer0.51192100.000009-14.0-13.10.2
207-1258A-42R-6,115-116.5397.69422.6493.70Micromass Sector 54 thermal ionization mass spectrometer0.51192500.000006-13.9-13.10.1
207-1258A-42R-7,7-9398.01422.9693.74Nu multi-collector inductively coupled mass spectrometer0.51196700.000005-13.1-12.20.1
207-1258A-42R-7,25-26.5398.19423.1493.75Micromass Sector 54 thermal ionization mass spectrometer0.51197800.000008-12.9-12.00.2
207-1258A-42R-7,25-26.5398.19423.1493.75Micromass Sector 54 thermal ionization mass spectrometer0.51196300.000009-13.2-12.30.2
207-1258A-42R-7,70-71.5398.64423.5993.80Micromass Sector 54 thermal ionization mass spectrometer0.51217500.000011-9.0-8.20.2
207-1258A-42R-7,70-71.5398.64423.5993.80Micromass Sector 54 thermal ionization mass spectrometer0.51217700.000010-9.0-8.10.2
207-1258A-42R-7,92-94398.86423.8193.82Micromass Sector 54 thermal ionization mass spectrometer0.51207400.000009-11.0-10.10.2
207-1258A-42R-7,92-94398.86423.8193.82Micromass Sector 54 thermal ionization mass spectrometer0.51205600.000006-11.4-10.50.1
207-1258A-45R-2,57-59420.55445.4395.98Nu multi-collector inductively coupled mass spectrometer0.51180000.000004-16.4-15.50.10.1262
207-1258A-46R-2,68-70425.34450.2296.46Nu multi-collector inductively coupled mass spectrometer0.51183300.000009-15.7-14.80.20.1218
207-1258A-46R-4,33-35427.65452.5396.69Nu multi-collector inductively coupled mass spectrometer0.51181200.000005-16.1-15.20.1
207-1258A-47R-1,12-14428.42456.0497.04Nu multi-collector inductively coupled mass spectrometer0.51187300.000008-14.9-14.10.2
207-1258A-48R-2,47-49434.76462.6897.71Micromass Sector 54 thermal ionization mass spectrometer0.51185100.000008-15.4-14.50.2
207-1258A-48R-2,47-49434.76462.6897.71Micromass Sector 54 thermal ionization mass spectrometer0.51183600.000009-15.7-14.80.2