Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Pettke, Thomas; Halliday, Alex N; Rea, David K (2002): (Table 1) Nd isotopic composition, and Sm and ND concentrations of eolian dust from sediment core LL44 GPC3 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.715019, In supplement to: Pettke, T et al. (2002): Cenozoic evolution of Asian climate and sources of Pacific seawater Pb and Nd derived from eolian dust of sediment core LL44-GPC3. Paleoceanography, 17(3), 1031, https://doi.org/10.1029/2001PA000673

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 30.331700 * Longitude: -157.831700
Minimum DEPTH, sediment/rock: 0.73 m * Maximum DEPTH, sediment/rock: 23.20 m
Event(s):
LL44-GPC-3 * Latitude: 30.331700 * Longitude: -157.831700 * Elevation: -5705.0 m * Location: Central North Pacific * Method/Device: Piston corer (PC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmGeocode
2Sample code/labelSample labelPettke, ThomasUniversity og Rhode Island sample accession number
3Age modelAge modelkaPettke, ThomasAge model, biostratigraphyChronostratigraphic age based on ichthyolith biostratigraphy (Doyle and Riedel, 1980) as employed by Janecek and Rea (1983)
4Age model, optionalAge model optkaPettke, ThomasChronostratigraphic age based on the age model of constant flux of hydrogenous Co (Kyte et al., 1993 doi:10.1016/0016-7037(93)90109-A)
5SamariumSmmg/kgPettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
6NeodymiumNdmg/kgPettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
7Samarium-147/Neodymium-144 ratio147Sm/144NdPettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
8Neodymium-143/Neodymium-144 ratio143Nd/144NdPettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)Data are normalized to the natural ratio of 143Nd/144Nd = 0.511847 (Wasserburg et al., 1981 doi:10.1016/0016-7037(81)90085-5)
9Neodymium-143/Neodymium-144 ratio, error143Nd/144Nd e±Pettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)2 sigma
10ε-Neodymiumε-NdPettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)modern
11ε-Neodymium (T)ε-Nd(T)Pettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
12ε-Neodymium, standard deviationε-Nd std dev±Pettke, ThomasMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)2 sigma
Size:
630 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML