Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Rickli, Jörg Dominik; Frank, Martin; Halliday, Alex N (2009): Hafnium-neodymium isotopic composition measured on water bottle samples at station Tha15 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.714997, In supplement to: Rickli, JD et al. (2009): The hafnium-neodymium isotopic composition of Atlantic seawater. Earth and Planetary Science Letters, 280(1-4), 118-127, https://doi.org/10.1016/j.epsl.2009.01.026

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 54.246000 * Longitude: -48.091300
Date/Time Start: 2005-07-23T20:11:00 * Date/Time End: 2005-07-23T20:11:00
Minimum DEPTH, water: 50 m * Maximum DEPTH, water: 1000 m
Event(s):
WNA05_15 (Tha15) * Latitude: 54.246000 * Longitude: -48.091300 * Date/Time: 2005-07-23T20:11:00 * Elevation: -3973.0 m * Campaign: WNA05 * Basis: Thalassa * Method/Device: CTD/Rosette (CTD-RO)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, waterDepth watermGeocode
Temperature, water, potentialTpot°CFischer, JürgenCTD
SalinitySalFischer, JürgenCTD
ε-Hafniumε-HfRickli, Jörg DominikMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)Hf isotopic compositions as relative deviations from the chondritic uniform reservoir: epsilon = (Rsample-RCHUR)/Rsample *10**4 with RCHUR = 176Hf/177HfCHUR = 0.282769 (Nowell et al., 1998)
ε-Hafnium, standard deviationε-Hf std dev±Rickli, Jörg DominikMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)Internal error, 2 S.E.M.
ε-Hafnium, standard deviationε-Hf std dev±Rickli, Jörg DominikMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)External error, 2-sigma error
Hafnium, dissolvedHf disspmol/kgRickli, Jörg DominikMC-ICP-MS, isotope dilution+/- 3%
ε-Neodymiumε-NdRickli, Jörg DominikMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)+/- 0.3, 2-sigma error; Nd isotopic compositions as relative deviations from the chondritic uniform reservoir: epsilon = (Rsample-RCHUR)/Rsample *10**4 with RCHUR = 143Nd/144NdCHUR = 0.512638 (Jacobsen and Wasserburg, 1980)
Neodymium, dissolvedNd disspmol/kgRickli, Jörg DominikMC-ICP-MS, isotope dilution+/-1 %
Size:
16 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth water [m]

Tpot [°C]
(CTD)

Sal
(CTD)

ε-Hf
(Hf isotopic compositions as r...)

ε-Hf std dev [±]
(Internal error, 2 S.E.M., Mul...)

ε-Hf std dev [±]
(External error, 2-sigma error...)

Hf diss [pmol/kg]
(+/- 3%, MC-ICP-MS, isotope di...)

ε-Nd
(+/- 0.3, 2-sigma error; Nd is...)

Nd diss [pmol/kg]
(+/-1 %, MC-ICP-MS, isotope di...)
506.62234.690-3.110.650.590.61-17.3124.0
10003.46434.872-2.120.850.750.67-14.8020.9