Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Henderson, Gideon M; Martel, D J; O'Nions, R K; Shackleton, Nicholas J (1994): (Table 1) 87Sr/86Sr ratios of planktonic foraminifera from ODP Site 121-758 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.712119, In supplement to: Henderson, GM et al. (1994): Evolution of seawater 87Sr/86Sr over the last 400 ka: the absence of glacial/interglacial cycles. Earth and Planetary Science Letters, 128(3-4), 643-651, https://doi.org/10.1016/0012-821X(94)90176-7

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 5.384067 * Longitude: 90.361167
Date/Time Start: 1988-06-15T00:00:00 * Date/Time End: 1988-06-15T00:00:00
Minimum DEPTH, sediment/rock: 0.01 m * Maximum DEPTH, sediment/rock: 6.92 m
Event(s):
121-758 * Latitude: 5.384067 * Longitude: 90.361167 * Date/Time Start: 1988-06-15T00:00:00 * Date/Time End: 1988-06-15T00:00:00 * Elevation: -2935.0 m * Penetration: 782.2 m * Recovery: 561.9 m * Location: Indian Ocean * Campaign: Leg121 * Basis: Joides Resolution * Method/Device: Composite Core (COMPCORE) * Comment: 84 cores; 782.2 m cored; 0 m drilled; 71.8% recovery
Comment:
Ages are estimated from delta18O isotope stratigraphy. 'Clean' samples were more thoroughly cleaned with water and methanol. Quoted errors in the 87Sr/86Sr ratio are in the last digit and are the 2 sigma internal statistics for that analysis. These are always less than +/- 0.000009, the long-term repeatability, which is shown in all figures and represents the true uncertainty on the analyses. For Delta 87Sr (ppm) errors shown are the 2 sigma internal error; external repeatability expressed in this form is 13 ppm.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1AGEAgeka BPGeocode
2DEPTH, sediment/rockDepth sedmGeocode
3Sample commentSample commentHenderson, Gideon M
4Strontium-87/Strontium-86 ratio87Sr/86SrHenderson, Gideon MMass spectrometer VG Sector 354 multicollector
5Strontium-87/Strontium-86 ratio, error87Sr/86Sr e±Henderson, Gideon MMass spectrometer VG Sector 354 multicollector2 sigma
6Δ87SrΔ87Srmg/kgHenderson, Gideon MCalculatedDelta 87Sr (ppm) = ((87Sr/86Sr in sample/0.709158)-1)*10**6
7Standard deviationStd dev±Henderson, Gideon MCalculatedDelta 87Sr, 2 sigma
Size:
95 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML