Wang, Daming; Van der Voo, Rob; Peacor, Donald R (2005): (Table 4) Magnetic properties of titanomagnetite in MORB younger than 100 Ma, DSDP Hole 82-562 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.711518, In supplement to: Wang, D et al. (2005): Why is the remanent magnetic intensity of Cretaceous MORB so much higher than that of mid to late Cenozoic MORB? Geosphere, 1(3), 138-146, https://doi.org/10.1130/GES00024.1
Always quote citation above when using data! You can download the citation in several formats below.
Project(s):
Deep Sea Drilling Project (DSDP)
Coverage:
Latitude: 33.141500 * Longitude: -41.679300
Date/Time Start: 1981-10-21T00:00:00 * Date/Time End: 1981-10-21T00:00:00
Minimum DEPTH, sediment/rock: 241.68 m * Maximum DEPTH, sediment/rock: 315.71 m
Event(s):
82-562 * Latitude: 33.141500 * Longitude: -41.679300 * Date/Time: 1981-10-21T00:00:00 * Elevation: -3172.0 m * Penetration: 331 m * Recovery: 42 m * Location: North Atlantic/RIDGE * Campaign: Leg82 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 10 cores; 81 m cored; 0 m drilled; 51.9 % recovery
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
2 | AGE | Age | ka BP | Geocode | ||
3 | Sample code/label | Sample label | Wang, Daming | DSDP/ODP/IODP sample designation | ||
4 | Curie temperature | Curie temp | °C | Wang, Daming | ||
5 | Hysteresis, saturation magnetization/ saturation remanence | Mrs/Ms | Wang, Daming | vibrating sample magnetometer (microVSM) | ||
6 | Hysteresis, coercivity of remanence/coercivity | Hcr/Hc | Wang, Daming | vibrating sample magnetometer (microVSM) | ||
7 | Hysteresis, saturation remanence | Mrs | mA m2/kg | Wang, Daming | vibrating sample magnetometer (microVSM) | |
8 | Coercivity | Hc | mT | Wang, Daming | vibrating sample magnetometer (microVSM) | |
9 | Natural remanent magnetization, Intensity per unit mass | Inten NRM | 10-6 A*m2/kg | Wang, Daming | vibrating sample magnetometer (microVSM) |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
37 data points
Data
1 Depth sed [m] | 2 Age [ka BP] | 3 Sample label | 4 Curie temp [°C] | 5 Mrs/Ms | 6 Hcr/Hc | 7 Mrs [mA m2/kg] | 8 Hc [mT] | 9 Inten NRM [10-6 A*m2/kg] |
---|---|---|---|---|---|---|---|---|
241.68 | 16000 | 82-562-1R-1,68-70 | 0.67 | 1.42 | 0.06 | 112.2 | 750 | |
242.13 | 16000 | 82-562-1R-1,113-115 | 284 | 0.50 | 1.31 | 0.41 | 37.6 | 1530 |
272.54 | 16000 | 82-562-4R-4,29-31 | 0.62 | 1.19 | 0.13 | 41.4 | ||
273.17 | 16000 | 82-562-4R-4,92-94 | 355 | 0.53 | 1.31 | 0.13 | 34.1 | 680 |
314.81 | 16000 | 82-562-10R-2,31-33 | 0.58 | 1.51 | 0.05 | 45.5 | 400 | |
315.71 | 16000 | 82-562-10R-2,121-123 | 0.63 | 1.21 | 0.12 | 48.5 | 1320 |