Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Robinson, Laura F; Noble, Taryn L; McManus, Jerry F (2008): (Table 3) Concentrations and isotopic ratios of thorium and uranium in sediments at Site EW9209-3JPC [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.711307, In supplement to: Robinson, LF et al. (2008): Measurement of adsorbed and total 232Th/230Th ratios from marine sediments. Chemical Geology, 252(3-4), 169-179, https://doi.org/10.1016/j.chemgeo.2008.02.015

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 5.313300 * Longitude: -44.260000
Minimum DEPTH, sediment/rock: 0.0150 m * Maximum DEPTH, sediment/rock: 0.0150 m
Event(s):
EW9209-3JPC * Latitude: 5.313300 * Longitude: -44.260000 * Elevation: -3288.0 m * Location: Ceara Rise * Method/Device: Piston corer (PC)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmGeocode
2AGEAgeka BPGeocode
3Depth, top/minDepth topmRobinson, Laura F
4Depth, bottom/maxDepth botmRobinson, Laura F
5Sample typeSamp typeRobinson, Laura F
6Method commentMethod commRobinson, Laura F
7Sample massSamp mgRobinson, Laura F
8Loss by dissolutionLBD%Robinson, Laura F
9Thorium-232232Thmg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to total samples
10Thorium-232232Thmg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to dissolved parts of samples
11Thorium-232, standard deviation232Th std dev±Robinson, Laura FCalculatedwith respect to total samples
12Thorium-232, standard deviation232Th std dev±Robinson, Laura FCalculatedwith respect to dissolved parts of samples
13Thorium-232/Thorium-230 ratio232Th/230ThRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometryatom ratio
14Thorium-232/Thorium-230, standard deviation232Th/230Th std dev±Robinson, Laura FCalculated
15Uranium-238238Umg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to total samples
16Uranium-238238Umg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to dissolved parts of samples
17Uranium-238, standard deviation238U std dev±Robinson, Laura FCalculatedwith respect to total samples
18Uranium-238, standard deviation238U std dev±Robinson, Laura FCalculatedwith respect to dissolved parts of samples
19Uranium-234/Uranium-238 activity ratio(234U/238U)Robinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometry
20Uranium-234/Uranium-238 activity ratio, standard deviation(234U/238U) std dev±Robinson, Laura FCalculated
Size:
161 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML