Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Robinson, Laura F; Noble, Taryn L; McManus, Jerry F (2008): (Table 3) Concentrations and isotopic ratios of thorium and uranium in sediments at ODP Site 177-1088. PANGAEA, https://doi.org/10.1594/PANGAEA.711297, In supplement to: Robinson, LF et al. (2008): Measurement of adsorbed and total 232Th/230Th ratios from marine sediments. Chemical Geology, 252(3-4), 169-179, https://doi.org/10.1016/j.chemgeo.2008.02.015

Always quote above citation when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: -41.136083 * Longitude: 13.562850
Date/Time Start: 1997-12-16T00:00:00 * Date/Time End: 1997-12-16T00:00:00
Minimum DEPTH, sediment/rock: 0.0150 m * Maximum DEPTH, sediment/rock: 0.0150 m
Event(s):
177-1088 * Latitude: -41.136083 * Longitude: 13.562850 * Date/Time: 1997-12-16T00:00:00 * Elevation: -2082.1 m * Penetration: 371.9 m * Recovery: 229.4 m * Location: South Atlantic Ocean * Campaign: Leg177 * Basis: Joides Resolution * Device: Composite Core (COMPCORE) * Comment: 28 cores; 253.4 m cored; 118.5 m drilled; 90.5% recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethodComment
1DEPTH, sediment/rockDepthmGeocode
2AGEAgeka BPGeocode
3Depth, top/minDepth topmRobinson, Laura F
4Depth, bottom/maxDepth botmRobinson, Laura F
5Sample typeSamp typeRobinson, Laura F
6Method commentMethod commRobinson, Laura F
7Sample massSamp mgRobinson, Laura F
8Loss by dissolutionLBD%Robinson, Laura F
9Thorium 232232Thmg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to total samples
10Thorium 232232Thmg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to dissolved parts of samples
11Thorium 232, standard deviation232Th std dev±Robinson, Laura FCalculatedwith respect to total samples
12Thorium 232, standard deviation232Th std dev±Robinson, Laura FCalculatedwith respect to dissolved parts of samples
13Thorium 232/Thorium 230 ratio232Th/230ThRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometryatom ratio
14Thorium 232/Thorium 230, standard deviation232Th/230Th std dev±Robinson, Laura FCalculated
15Uranium 238238Umg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to total samples
16Uranium 238238Umg/kgRobinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometrywith respect to dissolved parts of samples
17Uranium 238, standard deviation238U std dev±Robinson, Laura FCalculatedwith respect to total samples
18Uranium 238, standard deviation238U std dev±Robinson, Laura FCalculatedwith respect to dissolved parts of samples
19Uranium 234/Uranium 238 activity ratio(234U/238U)Robinson, Laura FSingle-collector inductively-coupled-plasma mass spectrometry
20Uranium 234/Uranium 238 activity ratio, standard deviation(234U/238U) std dev±Robinson, Laura FCalculated
Size:
65 data points

Download Data

Download dataset as tab-delimited text (use the following character encoding: )

View dataset as HTML