Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Janney, Philip E; Castillo, Paterno R (2001): (Table 2) Sr, Nd and Pb isotope ratios and parent-daughter elemental data for Mesozoic Atlantic crust [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.710999, In supplement to: Janney, PE; Castillo, PR (2001): Geochemistry of the oldest Atlantic oceanic crust suggests mantle plume involvement in the early history of the central Atlantic Ocean. Earth and Planetary Science Letters, 192(3), 291-302, https://doi.org/10.1016/S0012-821X(01)00452-6

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Median Latitude: 23.129982 * Median Longitude: -58.849018 * South-bound Latitude: -15.709800 * West-bound Longitude: -75.381700 * North-bound Latitude: 40.360800 * East-bound Longitude: -20.047200
Date/Time Start: 1970-04-20T00:00:00 * Date/Time End: 1981-02-28T00:00:00
Minimum Elevation: -5633.0 m * Maximum Elevation: -3909.0 m
Event(s):
11-100 * Latitude: 24.687800 * Longitude: -73.799700 * Date/Time: 1970-04-20T00:00:00 * Elevation: -5325.0 m * Penetration: 331 m * Recovery: 29.4 m * Location: North Atlantic/BASIN * Campaign: Leg11 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 13 cores; 93 m cored; 0 m drilled; 31.6 % recovery
11-105 * Latitude: 34.895300 * Longitude: -69.173300 * Date/Time: 1970-05-13T00:00:00 * Elevation: -5251.0 m * Penetration: 633 m * Recovery: 195.9 m * Location: North Atlantic/HILL * Campaign: Leg11 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 43 cores; 363 m cored; 0 m drilled; 54 % recovery
39-355 * Latitude: -15.709800 * Longitude: -30.600500 * Date/Time: 1974-11-08T00:00:00 * Elevation: -4901.0 m * Penetration: 461.5 m * Recovery: 117.6 m * Location: South Atlantic/BASIN * Campaign: Leg39 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 22 cores; 209 m cored; 0 m drilled; 56.2 % recovery
Comment:
Measured values for the NBS 987 (Sr) and La Jolla (Nd) isotopic standards are 87Sr/86Sr =0.71026 and 143Nd/144Nd= 0.511859 with total measured ranges of +/-0.000026 and +/-0.000014, respectively. A 1 per mil/amu fractionation correction was applied to Pb isotoperatios, based on repeat measurements of NBS 981, to conform to the values of Todt et al. (1969). External uncertainties for 206Pb/204Pb and 207Pb/204Pb are less than +/- 0.01, and for 208Pb/204Pb are less than +/- 0.03. Total procedural blanks for Sr, Nd and Pb isotope measurements are 20, 5 and 50 pg, respectively. Parent-daughter elemental concentrations were obtained by quadrupole ICPMS, on the samespecially treated sample material used for isotope ratio analysis. Replicate analysis of rock standards indicates that Sr concentrations are precise to within 2.5%, Rb, Sm and Nd are precise to within 5% and U, Th and Pb are precise to within 8%. Initial (age-corrected) isotope ratios were calculated assuming the numerical sample ages. epsilonNd(t) values are calculated for age-corrected sample and CHUR Nd isotope ratios (143Nd/144NdCHUR(t = 0) = 0.512638, 147Sm/144NdCHUR = 0.1967).
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEvent
2Latitude of eventLatitude
3Longitude of eventLongitude
4AGEAgeka BPGeocode
5Sample code/labelSample labelJanney, Philip EDSDP/ODP/IODP sample designation
6Sample commentSample commentJanney, Philip E
7RubidiumRbmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
8StrontiumSrmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
9Strontium-87/Strontium-86 ratio87Sr/86SrJanney, Philip EMass spectrometer thermal ionization
10Strontium-87/Strontium-86 ratio87Sr/86SrJanney, Philip EMass spectrometer thermal ionization
11SamariumSmmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
12NeodymiumNdmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
13Neodymium-143/Neodymium-144 ratio143Nd/144NdJanney, Philip EMass spectrometer thermal ionization
14Neodymium-143/Neodymium-144 ratio143Nd/144NdJanney, Philip EMass spectrometer thermal ionization
15ε-Neodymium (T)ε-Nd(T)Janney, Philip ECalculated
16UraniumUmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
17ThoriumThmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
18LeadPbmg/kgJanney, Philip EInductively coupled plasma - mass spectrometry (ICP-MS)
19Lead-206/Lead-204 ratio206Pb/204PbJanney, Philip EMass spectrometer thermal ionization
20Lead-206/Lead-204 ratio206Pb/204PbJanney, Philip EMass spectrometer thermal ionization
21Lead-207/Lead-204 ratio207Pb/204PbJanney, Philip EMass spectrometer thermal ionization
22Lead-207/Lead-204 ratio207Pb/204PbJanney, Philip EMass spectrometer thermal ionization
23Lead-208/Lead-204 ratio208Pb/204PbJanney, Philip EMass spectrometer thermal ionization
24Lead-208/Lead-204 ratio208Pb/204PbJanney, Philip EMass spectrometer thermal ionization
Size:
385 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML