/* DATA DESCRIPTION: Citation: Papavassiliou, C T; Cosgrove, M E (1982): (Table 2) Chemical composition of bulk sediment samples from DSDP Site 223. PANGAEA, https://doi.org/10.1594/PANGAEA.700866, In supplement to: Papavassiliou, CT; Cosgrove, ME (1982): The geochemistry of DSDP sediments from Site 223, Indian Ocean. Chemical Geology, 37(3-4), 299-315, https://doi.org/10.1016/0009-2541(82)90085-7 Project(s): Deep Sea Drilling Project (DSDP) (URI: http://www.deepseadrilling.org/) Coverage: LATITUDE: 18.749700 * LONGITUDE: 60.129700 DATE/TIME START: 1972-03-31T00:00:00 * DATE/TIME END: 1972-03-31T00:00:00 MINIMUM DEPTH, sediment/rock: 1 m * MAXIMUM DEPTH, sediment/rock: 686 m Event(s): 23-223 * LATITUDE: 18.749700 * LONGITUDE: 60.129700 * DATE/TIME: 1972-03-31T00:00:00 * ELEVATION: -3633.0 m * Penetration: 740 m * Recovery: 194.4 m * LOCATION: Indian Ocean/Arabian Sea/RIDGE * CAMPAIGN: Leg23 (URI: https://doi.org/10.2973/dsdp.proc.23.1974) * BASIS: Glomar Challenger (URI: http://www-odp.tamu.edu/glomar.html) * METHOD/DEVICE: Drilling/drill rig (DRILL) * COMMENT: 39 cores; 351 m cored; 0 m drilled; 55.4 % recovery Parameter(s): DEPTH, sediment/rock [m] (Depth sed) * GEOCODE Sample code/label (Sample label) * PI: Papavassiliou, C T * METHOD/DEVICE: DSDP/ODP/IODP sample designation (URI: hdl:10013/epic.27914.d001) Silicon [%] (Si) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Titanium [%] (Ti) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Aluminium [%] (Al) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Iron [%] (Fe) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Magnesium [%] (Mg) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Calcium [%] (Ca) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Sodium [%] (Na) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Potassium [%] (K) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Water in rock [%] (H2O) * PI: Papavassiliou, C T * METHOD/DEVICE: Gravimetric analysis Carbon dioxide [%] (CO2) * PI: Papavassiliou, C T * METHOD/DEVICE: Gravimetric analysis Phosphorus [mg/kg] (P) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Sulfur, total [mg/kg] (TS) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Vanadium [mg/kg] (V) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Chromium [mg/kg] (Cr) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Manganese [mg/kg] (Mn) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Nickel [mg/kg] (Ni) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Copper [mg/kg] (Cu) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Zinc [mg/kg] (Zn) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Gallium [mg/kg] (Ga) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Arsenic [mg/kg] (As) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Rubidium [mg/kg] (Rb) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Strontium [mg/kg] (Sr) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Yttrium [mg/kg] (Y) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Zirconium [mg/kg] (Zr) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Niobium [mg/kg] (Nb) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Molybdenum [mg/kg] (Mo) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Barium [mg/kg] (Ba) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Lanthanum [mg/kg] (La) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Cerium [mg/kg] (Ce) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder Lead [mg/kg] (Pb) * PI: Papavassiliou, C T * METHOD/DEVICE: X-ray fluorescence on pressed powder License: Creative Commons Attribution 3.0 Unported (CC-BY-3.0) (URI: https://creativecommons.org/licenses/by/3.0/) Size: 1236 data points */ Depth sed [m] Sample label Si [%] Ti [%] Al [%] Fe [%] Mg [%] Ca [%] Na [%] K [%] H2O [%] CO2 [%] P [mg/kg] TS [mg/kg] V [mg/kg] Cr [mg/kg] Mn [mg/kg] Ni [mg/kg] Cu [mg/kg] Zn [mg/kg] Ga [mg/kg] As [mg/kg] Rb [mg/kg] Sr [mg/kg] Y [mg/kg] Zr [mg/kg] Nb [mg/kg] Mo [mg/kg] Ba [mg/kg] La [mg/kg] Ce [mg/kg] Pb [mg/kg] 1 23-223-1-1 16.29 0.28 3.17 2.19 1.97 15.78 0.59 1.22 9.40 17.36 724 2445 72 130 850 87 46 108 6 1 47 780 13 102 12 3 460 43 13 35 23-223-2-6 21.84 0.39 3.81 3.31 2.91 14.35 0.52 1.43 4.02 15.78 741 6758 106 214 905 135 68 111 12 9 55 700 20 120 14 4 920 4 41 12 143 23-223-4-2 24.00 0.38 4.59 4.07 3.08 10.57 0.56 1.55 7.46 9.94 1014 7406 104 241 1354 187 82 153 13 12 68 473 26 164 14 5 722 22 43 17 145 23-223-4-3 19.16 0.26 3.72 2.83 2.47 13.59 0.58 1.29 7.95 14.95 990 4072 93 358 861 146 70 150 10 6 65 800 24 120 16 4 540 12 39 17 150 23-223-4-6 24.94 0.43 5.30 4.57 3.36 6.39 0.56 1.68 8.01 6.39 903 8681 114 247 893 201 87 131 12 9 74 324 25 169 19 12 604 16 58 16 152 23-223-5-2, 4-6 17.77 0.25 3.68 2.71 2.59 11.60 0.59 1.29 9.84 12.76 744 4830 100 208 1198 145 69 116 10 5 60 520 18 155 16 3 520 46 17 152 23-223-5-2, 36-38 24.83 0.36 5.03 3.85 3.20 6.28 0.52 1.54 7.00 10.83 633 4623 90 183 942 139 73 105 13 10 61 453 23 151 17 8 679 6 32 14 175 23-223-6-5, 124-126 24.99 0.45 5.08 3.99 3.86 7.85 0.53 1.69 4.36 8.64 661 3084 126 281 1259 184 52 112 13 6 68 360 20 170 17 9 1029 27 53 17 175 23-223-6-5, 128-130 17.60 0.24 3.49 2.44 2.03 15.61 0.55 1.23 9.33 17.17 824 1610 85 92 560 113 82 93 10 5 52 849 21 92 12 2 731 27 14 226 23-223-7-2 7.99 0.18 2.01 1.40 1.27 23.99 0.64 0.75 7.41 26.39 590 2043 55 94 574 91 65 58 6 3 25 1300 7 48 8 3 568 35 11 249 23-223-8-1 22.13 0.42 4.50 3.85 3.26 11.07 0.52 1.49 4.03 10.57 642 6591 89 279 703 167 57 94 13 4 65 497 22 160 17 3 566 11 44 12 317 23-223-11-6, 85-87 15.33 0.18 2.88 2.17 1.72 17.64 0.56 1.18 7.50 19.40 585 2482 98 125 781 109 95 102 11 4 35 1100 15 70 8 2 308 44 13 318 23-223-11-6, 125-127 26.61 0.43 4.73 3.76 3.11 9.19 0.60 1.58 4.16 8.84 526 4919 94 267 839 151 51 78 12 5 69 377 14 166 15 6 368 7 36 14 376 23-223-15-1 22.11 0.29 4.27 2.95 2.50 10.67 0.50 1.49 7.50 11.74 699 3406 97 163 1107 136 64 106 12 6 65 676 22 112 11 304 12 40 13 389 23-223-16-4 28.32 0.43 5.62 4.11 3.73 3.53 0.49 1.85 5.71 3.89 552 5437 127 294 847 203 65 110 14 6 87 308 21 180 15 6 494 16 45 18 391 23-223-16-5 9.98 0.13 1.88 1.32 1.15 23.68 0.64 0.71 6.75 26.05 707 1709 62 67 840 82 67 73 3 2 27 1274 9 50 10 5 450 39 10 395 23-223-17-2 24.91 0.25 3.30 2.59 2.07 10.80 0.44 1.17 7.52 11.88 628 2958 86 151 851 128 65 76 9 3 46 906 18 88 7 2 672 8 40 10 403 23-223-18-1 26.12 0.27 4.04 2.85 1.93 9.15 0.50 1.48 7.73 10.07 721 2759 121 153 1062 206 167 160 7 2 73 755 21 103 12 3 1708 53 25 409 23-223-18-5 24.68 0.18 2.61 2.01 1.43 13.49 0.54 0.97 7.76 14.84 534 3218 64 119 941 109 91 84 7 3 43 947 16 81 7 2 242 3 40 15 413 23-223-19-2 26.52 0.35 4.19 3.36 2.97 12.41 0.74 1.21 3.80 9.60 1427 7838 71 300 742 200 39 45 9 8 50 500 17 160 14 249 43 12 416 23-223-19-4 23.22 0.22 3.03 2.41 1.94 12.63 0.51 1.15 7.31 13.89 683 3920 79 148 985 148 83 92 9 5 53 876 15 98 12 2 424 7 84 9 422 23-223-20-2 26.63 0.39 4.90 3.92 3.08 9.25 0.51 1.74 4.51 7.89 728 2407 94 272 594 158 89 89 14 8 84 572 24 158 12 2 1060 49 13 426 23-223-20-cc 22.44 0.32 4.37 3.29 2.83 9.48 0.59 1.61 10.07 10.43 528 1074 85 260 990 185 99 70 12 3 66 764 17 154 13 618 65 15 430 23-223-21-1 16.37 0.27 3.39 2.73 2.29 14.28 0.58 1.41 7.49 15.71 471 1312 81 215 799 139 69 69 13 5 50 1050 16 123 10 536 42 10 452 23-223-23-1 17.33 0.27 3.74 2.62 1.74 14.92 0.61 1.39 6.59 16.41 468 1127 78 204 631 107 55 61 12 2 60 1081 17 127 10 3 585 51 11 482 23-223-26-3 4.26 0.10 1.50 1.21 0.92 28.82 0.67 0.56 7.00 31.70 275 690 25 51 421 40 79 27 3 4 22 1248 4 48 5 148 30 7 500 23-223-28-4 4.89 0.16 1.72 1.35 0.81 28.16 1.02 0.42 5.82 30.98 519 413 36 49 304 41 47 32 6 1 16 1185 9 80 14 1 747 27 6 530 23-223-30-4 4.05 0.16 1.80 1.12 0.65 29.31 0.93 0.36 4.66 32.24 383 398 34 42 533 21 32 27 5 1 14 1260 9 63 12 1 434 57 4 565 23-223-32-2 11.90 0.31 3.76 2.90 0.89 20.07 0.82 0.65 6.32 22.08 551 439 72 51 467 50 47 51 10 34 758 17 79 17 837 23 50 4 582 23-223-33-1 16.16 0.35 5.05 3.98 0.93 15.47 0.59 0.66 8.18 17.02 457 410 79 93 570 52 47 70 13 40 602 14 74 20 2 717 26 42 11 591 23-223-34-1 22.03 0.58 7.35 6.85 1.20 8.37 0.77 0.92 6.38 7.92 432 318 103 184 951 97 67 111 21 4 63 560 18 140 25 2 606 52 75 18 592 23-223-34-2, 30-32 22.67 0.60 7.71 6.74 1.25 6.65 0.80 0.93 7.36 4.84 429 288 104 140 1115 113 52 118 25 37 476 20 152 26 4 574 71 76 22 593 23-223-34-2, 130-132 22.99 0.59 7.65 6.17 1.35 6.98 0.78 0.90 6.42 6.38 441 289 118 150 937 107 55 114 21 34 510 23 146 26 645 48 71 17 610 23-223-35-7 18.53 0.19 2.92 2.41 0.96 16.81 0.85 1.11 7.11 18.49 816 520 60 111 753 71 47 47 8 40 682 19 40 10 1158 12 48 5 611 23-223-35-2 38.33 0.24 3.85 3.12 1.00 0.61 0.69 1.10 2.34 0.66 431 340 56 88 346 84 32 55 10 1 55 258 17 53 12 932 15 30 9 613 23-223-35-cc 37.37 0.23 3.62 2.80 0.89 2.82 0.61 1.01 1.40 3.10 436 288 50 69 408 71 37 51 9 2 55 278 15 56 9 826 11 32 6 629 23-223-36- 1 29.28 0.24 3.84 3.27 1.05 7.38 0.85 1.31 5.58 8.12 480 318 54 100 1398 96 50 63 10 1 45 421 14 58 12 710 34 30 9 630 23-223-36-cc 32.46 0.34 5.32 4.83 1.42 0.99 0.84 1.63 6.91 1.09 843 390 75 149 545 135 52 89 12 2 79 453 26 78 9 964 37 46 14 657 23-223-37-cc 24.76 0.63 9.51 6.96 1.30 0.88 0.41 0.94 7.50 0.30 574 823 130 120 448 96 42 157 26 10 58 262 27 115 21 966 65 103 25 685 23-223-38-1 25.01 0.63 9.76 7.07 1.27 1.14 0.73 0.98 7.00 0.00 637 396 129 114 432 76 48 118 25 13 80 117 19 118 31 507 66 91 18 686 23-223-38-cc 25.62 0.62 9.67 6.94 1.24 1.39 0.61 0.89 7.50 0.10 515 286 123 126 382 87 38 119 25 5 74 120 20 118 27 609 81 84 22