Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Berger, Glenn W (2007): (Table 5) Luminescence-dating of sediment core PS2185-3 of the Arctic Ocean [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.669561, In supplement to: Berger, GW (2006): Trans-arctic-ocean tests of fine-silt luminescence sediment dating provide a basis for an additional geochronometer for this region. Quaternary Science Reviews, 25(19-20), 2529-2551, https://doi.org/10.1016/j.quascirev.2005.07.024

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 87.529300 * Longitude: 144.166200
Date/Time Start: 1991-09-02T00:00:00 * Date/Time End: 1991-09-02T00:00:00
Minimum DEPTH, sediment/rock: 0.026 m * Maximum DEPTH, sediment/rock: 0.765 m
Event(s):
PS2185-3 (PS19/186) * Latitude: 87.529300 * Longitude: 144.166200 * Date/Time: 1991-09-02T00:00:00 * Elevation: -1073.0 m * Penetration: 0.33 m * Recovery: 0.37 m * Location: Lomonosov Ridge, Arctic Ocean * Campaign: ARK-VIII/3 (PS19 ARCTIC91) * Basis: Polarstern * Method/Device: Giant box corer (GKG)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmBerger, Glenn W
Depth, bottom/maxDepth botmBerger, Glenn W
Sample code/labelSample labelBerger, Glenn W
Dose rateD smGy/aBerger, Glenn Wcosmic ray component is estimated to be zero, based on the large water depths
Dose rate, standard deviationD std dev±Berger, Glenn Wdose rate, [mGy/a]
Dose rate, standard deviationD std dev±Berger, Glenn Wdose rate equivalent [Gy]
Equivalent doseDeGyBerger, Glenn W
Method commentMethod commBerger, Glenn W
10 Age, datedAge datedkaBerger, Glenn Wluminescence
11 Age, datedAge datedkaBerger, Glenn Wexpected, 14C yrs B.P. either from data representing close horizons or from interpolation and extrapolation from other dated horizons or from correlations
12 Age, dated standard deviationAge dated std dev±Berger, Glenn Wluminescence
13 DifferenceDiffBerger, Glenn Wdifference between calculated luminescence age and the expected age
Size:
56 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Depth top [m]

Depth bot [m]

Sample label

D s [mGy/a]
(cosmic ray component is estim...)

D std dev [±]
(dose rate, [mGy/a])

D std dev [±]
(dose rate equivalent [Gy])

De [Gy]

Method comm
10 
Age dated [ka]
(luminescence)
11 
Age dated [ka]
(expected, 14C yrs B.P. either...)
12 
Age dated std dev [±]
(luminescence)
13 
Diff
(difference between calculated...)
0.0260.0120.040BRM99-52260260.01.326.2IR-PSL detected at ca 420 nm. Filters GG400+K5-58+BG3911.63.01.29
0.0260.0120.040BRM99-53.042.4IR-PSL detected at 560 nm. Filters GG515+BG3918.81.716
0.1100.0900.130BRM99-648001000.031.0227.0IR-PSL detected at ca 420 nm. Filters GG400+K5-58+BG3947.715.07.633
0.2000.1800.220BRM99-73540600.036.0421.0weighted (by inverse variance) mean of the 420- and 560-nm IR-PSL results, when they are not different at a 1sigma level of confidence119.0>40.017.080
0.7650.7500.780BRM99-82770250.0180.0930.0weighted (by inverse variance) mean of the 420- and 560-nm IR-PSL results, when they are not different at a 1sigma level of confidence336.0>40.072.0