Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Augustin, Nico (2007): Trace element and REE element composition of rocks at Station M60/3-53-ROV-2 (Table4) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.602428

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Augustin, Nico; Paulick, Holger; Lackschewitz, Klas Sven; Eisenhauer, Anton; Garbe‐Schönberg, D; Kuhn, Thomas; Botz, Reiner; Schmidt, Martin (2012): Alteration at the ultramafic‐hosted Logatchev hydrothermal field: Constraints from trace element and Sr‐O isotope data. Geochemistry, Geophysics, Geosystems, 13(3), 2011GC003903, https://doi.org/10.1029/2011GC003903
Funding:
German Research Foundation (DFG), grant/award no. 5471797: From Mantle to Ocean: Energy-, Material- and Life-cycles at Spreading Axes
Coverage:
Latitude: 14.751758 * Longitude: -44.978367
Date/Time Start: 2004-01-30T17:17:00 * Date/Time End: 2004-01-30T17:17:00
Minimum DEPTH, sediment/rock: 0.00 m * Maximum DEPTH, sediment/rock: 0.00 m
Event(s):
M60/3-53-ROV-2 * Latitude: 14.751758 * Longitude: -44.978367 * Date/Time: 2004-01-30T17:17:00 * Elevation: -2978.0 m * Location: Mid-Atlantic Ridge at 10-15°N * Campaign: M60/3 (HYDROMAR1) * Basis: Meteor (1986) * Method/Device: Remote operated vehicle (ROV) * Comment: rock sampling
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, sediment/rockDepth sedmGeocode
2Sample code/labelSample label
3LithiumLimg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
4ScandiumScmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
5VanadiumVmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
6ChromiumCrmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
7CobaltComg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
8NickelNimg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
9CopperCumg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
10ZincZnmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
11GalliumGamg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
12RubidiumRbmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
13StrontiumSrmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
14YttriumYmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
15ZirconiumZrmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
16NiobiumNbmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
17CaesiumCsmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
18BariumBamg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
19LanthanumLamg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
20CeriumCemg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
21PraseodymiumPrmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
22NeodymiumNdmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
23SamariumSmmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
24EuropiumEumg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
25GadoliniumGdmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
26TerbiumTbmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
27DysprosiumDymg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
28HolmiumHomg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
29ErbiumErmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
30ThuliumTmmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
31YtterbiumYbmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
32LutetiumLumg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
33HafniumHfmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
34TantalumTamg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
35TitaniumTimg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
36LeadPbmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
37ThoriumThmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
38UraniumUmg/kgAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
39Sample typeSamp typeAugustin, NicoInductively coupled plasma - mass spectrometry (ICP-MS)
Size:
38 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML