Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Holz, Christine; Michels, Klaus (2001): Color measurements on sediment core PS2813-1. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.58263, In supplement to: Holz, Christine (2001): Glazialmarine Sedimentationsprozesse am Kontinentalhang des westlichen Weddellmeeres. Diploma Thesis, Geologisch-Paläontologisches Institut der Christian-Albrechts-Universität zu Kiel, Germany, 70 pp, hdl:10013/epic.30824.d001

Always quote above citation when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -66.730000 * Longitude: -50.000660
Date/Time Start: 1997-02-21T07:07:00 * Date/Time End: 1997-02-21T09:04:00
Minimum DEPTH, sediment/rock: 0.02 m * Maximum DEPTH, sediment/rock: 10.65 m
Event(s):
PS2813-1 (PS43/036) * Latitude: -66.730000 * Longitude: -50.000660 * Date/Time Start: 1997-02-21T07:07:00 * Date/Time End: 1997-02-21T09:04:00 * Elevation: -3499.0 m * Recovery: 10.64 m * Location: Weddell Sea * Campaign: ANT-XIV/3 (PS43) * Basis: Polarstern * Device: Piston corer (Kiel type) (KOL) * Comment: 11 core sections: 0-0.64, 0.64-1.64, 1.64-2.64, 2.64-3.64, 3.64-4.64, 4.64-5.64, 5.64-6.64, 6.64-7.64, 7.64-8.64, 8.64-9.64, 9.64-10.64 m
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethodComment
1DEPTH, sediment/rockDepthmGeocode
2Color, L*, lightnessL*Michels, KlausSpectrophotometer Minolta CM-2002
3Color, a*a*Michels, KlausSpectrophotometer Minolta CM-2002
4Color, b*b*Michels, KlausSpectrophotometer Minolta CM-2002
5Color code HLS-systemColor HLSMichels, KlausMunsell Color System (1994)
6Color reflectance at 400 nm wavelengthColor 400%Michels, KlausSpectrophotometer Minolta CM-2002
7Color reflectance at 410 nm wavelengthColor 410%Michels, KlausSpectrophotometer Minolta CM-2002
8Color reflectance at 420 nm wavelengthColor 420%Michels, KlausSpectrophotometer Minolta CM-2002
9Color reflectance at 430 nm wavelengthColor 430%Michels, KlausSpectrophotometer Minolta CM-2002
10Color reflectance at 440 nm wavelengthColor 440%Michels, KlausSpectrophotometer Minolta CM-2002
11Color reflectance at 450 nm wavelengthColor 450%Michels, KlausSpectrophotometer Minolta CM-2002
12Color reflectance at 460 nm wavelengthColor 460%Michels, KlausSpectrophotometer Minolta CM-2002
13Color reflectance at 470 nm wavelengthColor 470%Michels, KlausSpectrophotometer Minolta CM-2002
14Color reflectance at 480 nm wavelengthColor 480%Michels, KlausSpectrophotometer Minolta CM-2002
15Color reflectance at 490 nm wavelengthColor 490%Michels, KlausSpectrophotometer Minolta CM-2002
16Color reflectance at 500 nm wavelengthColor 500%Michels, KlausSpectrophotometer Minolta CM-2002
17Color reflectance at 510 nm wavelengthColor 510%Michels, KlausSpectrophotometer Minolta CM-2002
18Color reflectance at 520 nm wavelengthColor 520%Michels, KlausSpectrophotometer Minolta CM-2002
19Color reflectance at 530 nm wavelengthColor 530%Michels, KlausSpectrophotometer Minolta CM-2002
20Color reflectance at 540 nm wavelengthColor 540%Michels, KlausSpectrophotometer Minolta CM-2002
21Color reflectance at 550 nm wavelengthColor 550%Michels, KlausSpectrophotometer Minolta CM-2002
22Color reflectance at 560 nm wavelengthColor 560%Michels, KlausSpectrophotometer Minolta CM-2002
23Color reflectance at 570 nm wavelengthColor 570%Michels, KlausSpectrophotometer Minolta CM-2002
24Color reflectance at 580 nm wavelengthColor 580%Michels, KlausSpectrophotometer Minolta CM-2002
25Color reflectance at 590 nm wavelengthColor 590%Michels, KlausSpectrophotometer Minolta CM-2002
26Color reflectance at 600 nm wavelengthColor 600%Michels, KlausSpectrophotometer Minolta CM-2002
27Color reflectance at 610 nm wavelengthColor 610%Michels, KlausSpectrophotometer Minolta CM-2002
28Color reflectance at 620 nm wavelengthColor 620%Michels, KlausSpectrophotometer Minolta CM-2002
29Color reflectance at 630 nm wavelengthColor 630%Michels, KlausSpectrophotometer Minolta CM-2002
30Color reflectance at 640 nm wavelengthColor 640%Michels, KlausSpectrophotometer Minolta CM-2002
31Color reflectance at 650 nm wavelengthColor 650%Michels, KlausSpectrophotometer Minolta CM-2002
32Color reflectance at 660 nm wavelengthColor 660%Michels, KlausSpectrophotometer Minolta CM-2002
33Color reflectance at 670 nm wavelengthColor 670%Michels, KlausSpectrophotometer Minolta CM-2002
34Color reflectance at 680 nm wavelengthColor 680%Michels, KlausSpectrophotometer Minolta CM-2002
35Color reflectance at 690 nm wavelengthColor 690%Michels, KlausSpectrophotometer Minolta CM-2002
36Color reflectance at 700 nm wavelengthColor 700%Michels, KlausSpectrophotometer Minolta CM-2002
37Color, XXMichels, KlausSpectrophotometer Minolta CM-2002
38Color, YYMichels, KlausSpectrophotometer Minolta CM-2002
39Color, ZZMichels, KlausSpectrophotometer Minolta CM-2002
40Color REDredMichels, KlausSpectrophotometer Minolta CM-2002normalized
41Color GREENgreenMichels, KlausSpectrophotometer Minolta CM-2002normalized
42Color BLUEblueMichels, KlausSpectrophotometer Minolta CM-2002normalized
Size:
43788 data points

Download Data

Download dataset as tab-delimited text (use the following character encoding: )

View dataset as HTML (shows only first 2000 rows)