Rossak, B T (2000): Clay minerals in surface sediment of the Laptev Sea (Table1) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.56285
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Rossak, B T; Kassens, Heidemarie; Lange, Heinz; Thiede, Jörn (1999): Clay mineral distribution in surface sediments of the Laptev Sea: indicator for sediment provinces, dynamics and sources. In: Kassens, H; Bauch, H A; Dmitrenko, I A; Eicken, H; Hubberten, H-W; Melles, M; Thiede, J & Timokhov, L A (eds.), Land-ocean systems in the Siberian Arctic: dynamics and history, Springer, Berlin, Heidelberg, 587-600
Project(s):
Funding:
Fourth Framework Programme (FP4), grant/award no. MAS3980185: Quaternary Environment of the Eurasian North
Coverage:
Median Latitude: 74.290118 * Median Longitude: 129.361076 * South-bound Latitude: 71.690000 * West-bound Longitude: 113.996667 * North-bound Latitude: 77.111667 * East-bound Longitude: 139.670000
Date/Time Start: 1993-08-10T00:00:00 * Date/Time End: 1993-09-13T00:00:00
Minimum DEPTH, sediment/rock: 0.0 m * Maximum DEPTH, sediment/rock: 0.0 m
Event(s):
IK93K1-1 * Latitude: 75.940000 * Longitude: 136.708333 * Date/Time: 1993-09-09T00:00:00 * Elevation: -20.0 m * Location: Laptev Sea * Campaign: Transdrift-I * Basis: Ivan Kireyev * Method/Device: Box corer (Reineck) (BCR)
IK93K2-1 * Latitude: 76.835000 * Longitude: 137.295000 * Date/Time: 1993-09-13T00:00:00 * Elevation: -30.0 m * Location: Laptev Sea * Campaign: Transdrift-I * Basis: Ivan Kireyev * Method/Device: Box corer (Reineck) (BCR)
IK93Z2-8 * Latitude: 73.666667 * Longitude: 113.996667 * Date/Time: 1993-08-11T00:00:00 * Elevation: -9.0 m * Location: Laptev Sea * Campaign: Transdrift-I * Basis: Ivan Kireyev * Method/Device: Box corer (Reineck) (BCR)
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | ||||
2 | Latitude of event | Latitude | ||||
3 | Longitude of event | Longitude | ||||
4 | Elevation of event | Elevation | m | |||
5 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
6 | Illite | Ill | % | Rossak, B T | X-ray diffraction TEXTUR, clay fraction | |
7 | Smectite | Sme | % | Rossak, B T | X-ray diffraction TEXTUR, clay fraction | |
8 | Chlorite | Chl | % | Rossak, B T | X-ray diffraction TEXTUR, clay fraction | |
9 | Kaolinite | Kln | % | Rossak, B T | X-ray diffraction TEXTUR, clay fraction | |
10 | Illite crystallinity | Ill cryst | d2Theta | Rossak, B T | X-ray diffraction TEXTUR, clay fraction |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
240 data points
Data
1 Event | 2 Latitude | 3 Longitude | 4 Elevation [m] | 5 Depth sed [m] | 6 Ill [%] | 7 Sme [%] | 8 Chl [%] | 9 Kln [%] | 10 Ill cryst [d2Theta] |
---|---|---|---|---|---|---|---|---|---|
IK9301-6 | 71.7533 | 135.6600 | -16.0 | 0.0 | 50 | 13 | 28 | 9 | 0.31 |
IK9306-6 | 72.0117 | 130.9867 | -18.0 | 0.0 | 57 | 10 | 24 | 9 | 0.25 |
IK9307-3 | 72.5500 | 131.2967 | -21.0 | 0.0 | 51 | 7 | 29 | 13 | 0.24 |
IK9309-4 | 72.4900 | 136.5867 | -24.0 | 0.0 | 60 | 5 | 26 | 9 | 0.29 |
IK9313-6 | 73.0700 | 139.4267 | -16.0 | 0.0 | 56 | 3 | 31 | 10 | 0.22 |
IK9315-1 | 73.0000 | 133.4717 | -18.0 | 0.0 | 54 | 9 | 26 | 11 | 0.26 |
IK9316-6 | 73.0017 | 131.5017 | -28.0 | 0.0 | 53 | 10 | 25 | 12 | 0.24 |
IK9318-3 | 73.4983 | 137.5233 | -24.0 | 0.0 | 59 | 6 | 26 | 9 | 0.26 |
IK9320-1 | 73.4950 | 131.5200 | -18.0 | 0.0 | 54 | 9 | 26 | 11 | 0.21 |
IK9321-5 | 73.4783 | 131.6483 | -25.0 | 0.0 | 51 | 12 | 25 | 12 | 0.24 |
IK9323-6 | 73.6300 | 139.6533 | -17.0 | 0.0 | 51 | 8 | 28 | 13 | 0.26 |
IK9324-4 | 73.5017 | 121.6683 | -13.0 | 0.0 | 44 | 16 | 23 | 17 | 0.36 |
IK9325-bg | 73.8320 | 117.8720 | -13.0 | 0.0 | 32 | 31 | 22 | 15 | 0.22 |
IK9326-1 | 73.9967 | 115.9000 | -16.0 | 0.0 | 35 | 31 | 21 | 13 | 0.21 |
IK9327-6 | 73.9983 | 119.8600 | -30.0 | 0.0 | 37 | 20 | 24 | 19 | 0.26 |
IK9330-5 | 74.0000 | 127.5033 | -27.0 | 0.0 | 46 | 17 | 23 | 14 | 0.25 |
IK9334-7 | 74.0000 | 137.6633 | -22.0 | 0.0 | 52 | 11 | 27 | 10 | 0.23 |
IK9336-3 | 74.4900 | 115.9833 | -16.0 | 0.0 | 35 | 28 | 22 | 15 | 0.21 |
IK9337-bg | 73.5020 | 117.8480 | -19.0 | 0.0 | 38 | 25 | 22 | 15 | 0.22 |
IK9338-5 | 74.4917 | 119.9550 | -34.0 | 0.0 | 42 | 20 | 21 | 17 | 0.27 |
IK9340-6 | 74.5000 | 122.9933 | -16.0 | 0.0 | 39 | 23 | 26 | 12 | 0.23 |
IK9342-6 | 74.5100 | 127.3483 | -34.0 | 0.0 | 43 | 24 | 22 | 11 | 0.23 |
IK9344-8 | 74.4050 | 131.0133 | -30.0 | 0.0 | 48 | 11 | 28 | 13 | 0.24 |
IK9346-4 | 74.4950 | 134.0350 | -14.0 | 0.0 | 46 | 18 | 26 | 10 | 0.24 |
IK9348-5 | 74.4833 | 137.0417 | -22.0 | 0.0 | 54 | 13 | 24 | 9 | 0.30 |
IK9348-6 | 74.4800 | 137.0450 | -22.0 | 0.0 | 54 | 11 | 25 | 10 | 0.26 |
IK9349-7 | 74.5000 | 139.6700 | -24.0 | 0.0 | 47 | 20 | 24 | 9 | 0.24 |
IK9350-6 | 75.0100 | 136.0300 | -31.0 | 0.0 | 45 | 22 | 23 | 10 | 0.26 |
IK9353-9 | 74.9600 | 129.7650 | -40.0 | 0.0 | 43 | 21 | 24 | 12 | 0.26 |
IK9356-2 | 74.9967 | 123.0150 | -33.0 | 0.0 | 43 | 18 | 24 | 15 | 0.25 |
IK9358-5 | 75.0167 | 119.8883 | -34.0 | 0.0 | 40 | 23 | 22 | 15 | 0.27 |
IK9361-10 | 74.9967 | 114.5333 | -45.0 | 0.0 | 36 | 26 | 20 | 18 | 0.25 |
IK9365-6 | 75.4683 | 119.9617 | -43.0 | 0.0 | 40 | 23 | 22 | 15 | 0.23 |
IK9367-2 | 75.4817 | 123.8417 | -44.0 | 0.0 | 42 | 22 | 22 | 14 | 0.25 |
IK9368-8 | 75.4250 | 125.8300 | -41.0 | 0.0 | 41 | 22 | 23 | 14 | 0.27 |
IK9370-7 | 75.2700 | 129.4650 | -44.0 | 0.0 | 43 | 24 | 22 | 11 | 0.24 |
IK9371-1 | 75.3833 | 131.8033 | -20.0 | 0.0 | 44 | 21 | 22 | 13 | 0.31 |
IK9373-8 | 75.3417 | 135.1667 | -43.0 | 0.0 | 51 | 18 | 21 | 10 | 0.26 |
IK9373A-6 | 75.8100 | 134.5833 | -46.0 | 0.0 | 48 | 18 | 23 | 11 | 0.26 |
IK9381-3 | 76.5267 | 133.3117 | -38.0 | 0.0 | 48 | 19 | 22 | 11 | 0.25 |
IK9382-6 | 76.5033 | 137.2717 | -25.0 | 0.0 | 51 | 12 | 26 | 11 | 0.25 |
IK9384-1 | 77.1117 | 137.2250 | -33.0 | 0.0 | 54 | 11 | 24 | 11 | 0.26 |
IK93K1-1 | 75.9400 | 136.7083 | -20.0 | 0.0 | 52 | 14 | 24 | 10 | 0.26 |
IK93K2-1 | 76.8350 | 137.2950 | -30.0 | 0.0 | 54 | 9 | 27 | 10 | 0.25 |
IK93Z2-8 | 73.6667 | 113.9967 | -9.0 | 0.0 | 31 | 30 | 20 | 19 | 0.27 |
IK93Z3-3 | 73.2950 | 119.8317 | -11.0 | 0.0 | 42 | 15 | 24 | 19 | 0.29 |
IK93Z4-4 | 72.0333 | 130.1267 | -14.0 | 0.0 | 51 | 14 | 26 | 9 | 0.27 |
IK93Z5-3 | 71.6900 | 137.0067 | -11.0 | 0.0 | 56 | 1 | 35 | 8 | 0.24 |