# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
1 | LATITUDE | Latitude | | | | Geocode |
2 | LONGITUDE | Longitude | | | | Geocode |
3 | DEPTH, sediment/rock | Depth sed | m | | | Geocode |
4 | Depth, top/min | Depth top | m | Reimann, Clemens | | |
5 | Depth, bottom/max | Depth bot | m | Reimann, Clemens | | |
6 | Sample code/label | Sample label | | Reimann, Clemens | | |
7 | Silver | Ag | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.001 ppm |
8 | Aluminium | Al | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
9 | Aluminium oxide | Al2O3 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
10 | Arsenic | As | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.1 ppm |
11 | Boron | B | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
12 | Barium | Ba | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
13 | Beryllium | Be | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.05 ppm |
14 | Bismuth | Bi | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.005 ppm |
15 | Bromine | Br | mg/kg | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
16 | Calcium | Ca | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
17 | Calcium oxide | CaO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
18 | Cadmium | Cd | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.001 ppm |
19 | Chlorine | Cl | % | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
20 | Cobalt | Co | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.2 ppm |
21 | Chromium | Cr | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
22 | Copper | Cu | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
23 | Iron | Fe | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
24 | Iron oxide, Fe2O3 | Fe2O3 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
25 | Mercury | Hg | mg/kg | Reimann, Clemens | CV-AAS, conc. HNO3 (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.06 ppm |
26 | Potassium | K | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 200 ppm |
27 | Potassium oxide | K2O | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
28 | Lanthanum | La | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
29 | Lithium | Li | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
30 | Magnesium | Mg | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 5 ppm |
31 | Magnesium oxide | MgO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
32 | Manganese | Mn | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
33 | Manganese oxide | MnO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
34 | Molybdenum | Mo | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.2 ppm |
35 | Nitrite | [NO2]- | mg/kg | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
36 | Nitrate | [NO3]- | µg/kg | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
37 | Sodium | Na | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 15 ppm |
38 | Sodium oxide | Na2O | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
39 | Nickel | Ni | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 1 ppm |
40 | Phosphorus | P | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 7 ppm |
41 | Phosphorus pentoxide | P2O5 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
42 | Phosphate | PO4 | % | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
43 | Lead | Pb | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.2 ppm |
44 | Sulfur, total | TS | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 5 ppm |
45 | Sulfate | [SO4]2- | % | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
46 | Antimony | Sb | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.01 ppm |
47 | Scandium | Sc | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.1 ppm |
48 | Selenium | Se | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.01 ppm |
49 | Silicon | Si | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
50 | Strontium | Sr | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
51 | Tellurium | Te | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.003 ppm |
52 | Thorium | Th | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
53 | Titanium | Ti | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
54 | Titanium dioxide | TiO2 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
55 | Vanadium | V | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
56 | Yttrium | Y | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
57 | Zinc | Zn | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
58 | Sum | Sum | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
59 | Loss on ignition | LOI | % | Reimann, Clemens | Gravimetric, 1050 °C (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.1 % |
60 | Fluorine | F | mg/kg | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
61 | Fluorine | F | mg/kg | Reimann, Clemens | Ion selective probe, sulfide electrode | |
62 | pH | pH | | Reimann, Clemens | pH, combination | fraction < 2mm, detection limit 0.1 |
63 | Conductivity of soil/sediment | Cond | mS/m | Reimann, Clemens | Potentiometric | fraction < 2mm, detection limit 1 mS/m |