| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
| 1 | LATITUDE | Latitude | | | | Geocode |
| 2 | LONGITUDE | Longitude | | | | Geocode |
| 3 | DEPTH, sediment/rock | Depth sed | m | | | Geocode |
| 4 | Sample code/label | Sample label | | Reimann, Clemens | | |
| 5 | Description | Description | | Reimann, Clemens | | |
| 6 | Mercury | Hg | mg/kg | Reimann, Clemens | CV-AAS, conc. HNO3 (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.06 ppm |
| 7 | Mercury | Hg | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
| 8 | Aluminium | Al | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
| 9 | Aluminium | Al | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 300 ppm |
| 10 | Boron | B | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
| 11 | Barium | Ba | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 12 | Barium | Ba | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 50 ppm |
| 13 | Beryllium | Be | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.05 ppm |
| 14 | Calcium | Ca | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
| 15 | Calcium | Ca | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 50 ppm |
| 16 | Calcium | Ca | % | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 % |
| 17 | Cobalt | Co | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.2 ppm |
| 18 | Cobalt | Co | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
| 19 | Chromium | Cr | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 20 | Chromium | Cr | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 5 ppm |
| 21 | Copper | Cu | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 22 | Iron | Fe | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
| 23 | Iron | Fe | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 200 ppm |
| 24 | Iron | Fe | % | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 100 ppm |
| 25 | Potassium | K | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 200 ppm |
| 26 | Potassium | K | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 40 ppm |
| 27 | Lanthanum | La | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 28 | Lanthanum | La | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
| 29 | Lithium | Li | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 30 | Magnesium | Mg | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 5 ppm |
| 31 | Magnesium | Mg | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 200 ppm |
| 32 | Manganese | Mn | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 33 | Manganese | Mn | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 80 ppm |
| 34 | Molybdenum | Mo | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.2 ppm |
| 35 | Molybdenum | Mo | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
| 36 | Sodium | Na | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 15 ppm |
| 37 | Sodium | Na | mg/kg | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 200 ppm |
| 38 | Sodium | Na | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 100 ppm |
| 39 | Nickel | Ni | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 1 ppm |
| 40 | Nickel | Ni | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 20 ppm |
| 41 | Phosphorus | P | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 7 ppm |
| 42 | Phosphorus | P | mg/kg | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 40 ppm |
| 43 | Sulfur, total | TS | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 5 ppm |
| 44 | Scandium | Sc | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.1 ppm |
| 45 | Scandium | Sc | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.1 ppm |
| 46 | Silicon | Si | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 10 ppm |
| 47 | Silicon | Si | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 0.23 % |
| 48 | Strontium | Sr | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 49 | Strontium | Sr | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 500 ppm |
| 50 | Thorium | Th | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 3 ppm |
| 51 | Thorium | Th | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.2 ppm |
| 52 | Titanium | Ti | % | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 53 | Titanium | Ti | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | fraction < 2mm, detection limit 30 ppm |
| 54 | Vanadium | V | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 55 | Yttrium | Y | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 56 | Zinc | Zn | mg/kg | Reimann, Clemens | ICP-AES, Aqua regia (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.5 ppm |
| 57 | Zinc | Zn | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 50 ppm |
| 58 | Aluminium oxide | Al2O3 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 59 | Calcium oxide | CaO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 60 | Iron oxide, Fe2O3 | Fe2O3 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 61 | Potassium oxide | K2O | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 62 | Magnesium oxide | MgO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 63 | Manganese oxide | MnO | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 64 | Sodium oxide | Na2O | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 65 | Phosphorus pentoxide | P2O5 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 66 | Silicon dioxide | SiO2 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 67 | Titanium dioxide | TiO2 | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 68 | Sum | Sum | % | Reimann, Clemens | X-ray fluorescence, Loss on Ignition corrected values (Reimann et al., 1998) | |
| 69 | Arsenic | As | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
| 70 | Arsenic | As | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.1 ppm |
| 71 | Gold | Au | ng/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.002 ppm |
| 72 | Bromine | Br | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
| 73 | Cerium | Ce | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit ??? |
| 74 | Caesium | Cs | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
| 75 | Europium | Eu | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.2 ppm |
| 76 | Hafnium | Hf | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
| 77 | Lutetium | Lu | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.05 ppm |
| 78 | Sample mass | Samp m | g | Reimann, Clemens | | sample weight irradiated for INAA analyses |
| 79 | Neodymium | Nd | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit ??? |
| 80 | Antimony | Sb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.1 ppm |
| 81 | Antimony | Sb | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.01 ppm |
| 82 | Selenium | Se | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 3 ppm |
| 83 | Selenium | Se | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.01 ppm |
| 84 | Samarium | Sm | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.1 ppm |
| 85 | Tantalum | Ta | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
| 86 | Terbium | Tb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
| 87 | Uranium | U | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.5 ppm |
| 88 | Tungsten | W | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 1 ppm |
| 89 | Ytterbium | Yb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 0.2 ppm |
| 90 | Rubidium | Rb | mg/kg | Reimann, Clemens | Element analysis, neutron activation (NAA) | fraction < 2mm, detection limit 15 ppm |
| 91 | Fluorine | F | mg/kg | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
| 92 | Sulfate | [SO4]2- | % | Reimann, Clemens | Ion chromatography | fraction < 2mm, detection limit ??? |
| 93 | Silver | Ag | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.001 ppm |
| 94 | Bismuth | Bi | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.005 ppm |
| 95 | Cadmium | Cd | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.001 ppm |
| 96 | Lead | Pb | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.2 ppm |
| 97 | Tellurium | Te | mg/kg | Reimann, Clemens | Element analysis, AAS, graphite furnace, Aqua regia (Reimann et al., 1998) | fraction < 2mm, detection limit 0.003 ppm |
| 98 | Loss on ignition | LOI | % | Reimann, Clemens | Gravimetric, 1050 °C (Reimann et al., 1998, NGU-GTK-CKE spec.publ. Trondheim) | fraction < 2mm, detection limit 0.1 % |
| 99 | pH | pH | | Reimann, Clemens | pH, combination | fraction < 2mm, detection limit 0.1 |
| 100 | Conductivity of soil/sediment | Cond | mS/m | Reimann, Clemens | Potentiometric | fraction < 2mm, detection limit 1 mS/m |