Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1991-10-14 00:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.511238, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1991-10-14T00:00:00 * Date/Time End: 1991-10-14T00:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 25723 m
Event(s):
GF_9169 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1991-10-14T00:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 11282 m
Size:
544 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130961.0-13.300.0
138960.0-13.02350.02.7
154958.0-12.52350.12.7
218950.0-13.62350.42.8
290941.0-14.92350.72.8
627900.0-14.72352.13.1
754885.0-14.72352.63.2
1016855.0-14.52353.73.0
1060850.0-14.52353.93.0
1463806.0-14.32355.63.1
1520800.0-14.72355.83.1
1567795.0-15.12356.03.1
2015749.0-18.52226.33.2
2125738.0-19.32196.53.2
2267724.0-20.32156.73.2
2518700.0-18.32097.13.1
3000656.0-20.72008.03.0
3114646.0-21.31998.32.9
3655600.0-25.01969.72.8
3963575.0-27.119510.62.7
4165559.0-28.519411.12.6
4558529.0-31.719312.22.5
4954500.0-35.019213.32.5
5957432.0-43.219016.02.4
6470400.0-47.419014.72.3
6587393.0-48.419014.52.3
7676332.0-57.318911.82.3
8311300.0-60.918810.32.3
8938271.0-64.51878.72.3
9428250.0-66.71867.52.3
9453249.0-66.81867.52.3
9650241.0-67.61857.02.6
9956229.0-69.02039.03.0
10061225.0-69.52079.92.9
10304216.0-70.521512.02.6
10415212.0-71.021611.82.5
10614205.0-71.921811.42.9
10759200.0-71.922011.13.1
11093189.0-71.922410.63.7
11282183.0-72.922710.33.8
11478177.0-72.923010.04.0
11545175.0-72.92319.94.1
12181157.0-73.02469.84.6
12449150.0-73.02529.94.2
12567147.0-73.025510.04.4
12607146.0-73.025610.14.4
12959137.5-73.126410.63.9
12980137.0-73.126410.73.9
13198132.0-73.126911.12.7
13471126.0-73.127411.83.0
13517125.0-73.127511.92.9
13756120.0-73.227912.62.3
13955116.0-73.228213.24.8
14135112.5-73.228413.75.4
14213111.0-73.228514.05.6
14824100.0-73.328816.83.1
1504596.3-73.328817.93.1
1544190.0-73.128919.73.3
1546189.7-73.028919.83.3
1566786.6-72.929020.87.4
1582584.3-72.829021.59.7
1598082.1-72.729122.28.6
1613380.0-72.629122.97.2
1632777.4-72.529123.95.4
1668772.8-72.329225.63.5
1686070.7-71.729226.42.5
1691870.0-71.529226.62.5
1702968.7-71.129227.22.3
1735865.0-69.929328.72.5
1766961.7-68.829330.22.8
1783760.0-68.229331.03.1
1816756.8-67.029432.53.9
1836155.0-66.429433.54.1
1855253.3-65.729434.44.2
1871451.9-65.129435.14.8
1891750.2-63.829436.15.6
1894250.0-63.629436.25.7
1905449.1-62.929436.75.9
1921947.8-62.029437.56.3
1959545.0-59.929539.38.3
1986543.1-58.429540.69.7
2013441.3-56.929541.99.1
2016541.1-56.829542.09.3
2033740.0-55.829741.510.0
2054838.7-54.730040.910.9
2071637.7-53.730340.610.9
2075037.5-53.530340.511.0
2114135.3-51.430940.012.0
2117835.1-51.231040.012.0
2119735.0-51.131040.112.0
2132834.3-50.331041.012.1
2168232.5-48.431043.412.0
2195231.2-46.931045.311.9
2197331.1-46.831045.511.9
2221230.0-46.031047.111.6
2255428.5-44.831049.411.1
2267328.0-44.431050.211.2
2309426.3-43.031053.111.3
2317126.0-42.731053.711.4
2343725.0-41.831055.511.8
2371424.0-40.931057.412.3
2379923.7-40.631058.012.4
2394523.2-40.131059.012.4
2430922.0-37.631061.412.1
2456621.2-35.831063.211.9
2490420.2-33.431065.510.9
2497420.0-32.931066.010.9
2533719.0-30.431272.210.7
2572318.0-27.731378.810.5