König-Langlo, Gert; Gernandt, Hartwig (2006): Radiosonde at Georg-Forster station on 1991-09-16 12:00h [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.511233, In supplement to: König-Langlo, G; Gernandt, H (2009): Compilation of ozonesonde profiles from the Antarctic Georg-Forster-Station from 1985 to 1992. Earth System Science Data, 1(1), 1-5, https://doi.org/10.5194/essd-1-1-2009

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: -70.770000 * Longitude: 11.830000
Date/Time Start: 1991-09-16T12:00:00 * Date/Time End: 1991-09-16T12:00:00
Minimum ALTITUDE: 130 m * Maximum ALTITUDE: 25171 m
Event(s):
GF_9164 * Latitude: -70.770000 * Longitude: 11.830000 * Date/Time: 1991-09-16T12:00:00 * Location: Antarctic * Campaign: Ozone_studies_1985-1992 * Basis: Georg Forster Station * Method/Device: Radiosonde (RADIO)
Comment:
Height of tropopause 19349 m
Size:
515 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Altitude [m]

PPPP [hPa]

TTT [°C]

dd [deg]

ff [m/s]

pO3 [mPa]
130990.0-5.917011.02.2
234977.0-4.71435.81.6
258974.0-4.51305.01.7
290970.0-4.11265.61.7
454950.0-4.81168.72.0
479947.0-4.91159.12.0
554938.0-4.611210.62.2
647927.0-4.311012.52.2
879900.0-6.210717.12.2
1072878.0-7.710521.02.2
1242859.0-9.19817.32.2
1305852.0-9.69516.02.2
1323850.0-9.79515.92.3
1414840.0-10.49615.42.4
1721807.0-12.910013.82.2
1788800.0-13.410113.52.2
1797799.0-13.410113.42.2
2622716.0-19.31209.82.3
2790700.0-19.51259.22.4
2951685.0-19.81308.82.4
3028678.0-19.91338.62.4
3261657.0-19.71438.22.3
3654623.0-22.21608.02.3
3929600.0-24.01667.82.2
4101586.0-25.11717.72.2
4905524.0-30.31908.02.0
5237500.0-32.419810.21.9
5927453.0-36.920715.01.7
6447420.0-40.221018.71.9
6778400.0-42.421221.11.7
7302370.0-45.721425.01.5
7708348.0-48.421528.01.5
7822342.0-49.121528.21.5
8668300.0-56.321529.51.5
9398267.0-62.521530.71.5
9801250.0-66.021531.31.4
10432225.0-71.421532.41.3
10836210.0-74.821533.01.2
10892208.0-75.321532.91.2
11061202.0-76.421632.41.1
11118200.0-76.821632.31.2
11533186.0-79.521831.21.4
11877175.0-80.921930.41.6
11975172.0-81.021930.21.7
12174166.0-81.322029.72.3
12525156.0-79.322228.93.3
12636153.0-79.522228.63.6
12748150.0-79.822328.43.7
13239137.5-80.822527.34.2
13598129.0-81.622726.54.6
13775125.0-82.022826.14.5
14192116.0-82.923125.34.3
14363112.5-83.323225.04.7
14538109.0-83.723324.75.0
15015100.0-84.723623.85.7
1554191.0-81.124023.06.3
1555390.8-81.124023.06.3
1560390.0-80.724023.16.3
1563589.5-80.524023.16.3
1620880.8-82.924324.05.8
1626480.0-83.124324.15.6
1680172.6-85.324525.03.9
1700170.0-86.124525.43.9
1738965.2-87.724726.03.9
1740665.0-87.624726.13.9
1742264.8-87.624726.13.9
1784360.0-85.924826.83.3
1805757.7-85.124927.23.0
1832255.0-84.124927.73.0
1873151.1-82.525128.43.2
1874251.0-82.625128.43.2
1885350.0-83.225128.63.1
1934945.7-85.925229.63.0
1943445.0-86.025229.72.9
1991741.2-86.325330.62.7
1995740.9-86.125430.72.7
2008040.0-85.625430.92.7
2026138.7-84.925431.32.8
2043537.5-84.125531.63.0
2063136.2-83.325532.03.3
2081935.0-82.625331.63.5
2085134.8-82.425331.53.6
2123532.5-80.825030.83.7
2168830.0-78.924630.03.9
2172629.8-78.824530.03.9
2200128.4-77.624329.63.9
2208228.0-77.324229.54.1
2222827.3-76.724029.44.4
2227027.1-76.724029.44.5
2250926.0-76.423829.24.3
2273525.0-76.123529.04.3
2275824.9-76.123529.04.3
2280524.7-76.023629.34.3
2297124.0-75.823830.34.3
2347522.0-75.224533.84.1
2350121.9-75.224534.04.1
2366221.3-75.024733.74.1
2394220.3-74.725133.34.1
2402820.0-74.225233.24.1
2426719.2-72.925533.04.0
2432919.0-72.54.0
2458218.2-71.14.0
2464818.0-70.44.0
2499017.0-67.14.0
2517116.5-65.34.0